1. Important Safety Information

Please read all instructions carefully before operating this appliance to ensure safe and efficient use. Retain this manual for future reference.

  • Electrical Safety: Ensure the unit is connected to a properly grounded 110V electrical outlet. Do not use extension cords.
  • Ventilation: Maintain adequate clearance around the unit for proper airflow to prevent overheating.
  • Placement: Place the unit on a stable, level surface capable of supporting its weight when fully loaded.
  • Cleaning: Disconnect power before cleaning or performing any maintenance.
  • Service: All servicing should be performed by qualified personnel.

2. Product Overview

The PEAKCOLD Commercial Bar Glass Froster (Model IM25GF-B) is designed for commercial use to rapidly chill and frost glasses, mugs, or plates. It features a durable construction and efficient cooling system.

PEAKCOLD Commercial Bar Glass Froster, rear view with power cord and casters.

Figure 2.1: Rear view of the PEAKCOLD Glass Froster, showing the power cord and casters.

PEAKCOLD Glass Froster installed in a bar setting.

Figure 2.2: The glass froster integrated into a commercial bar setup.

Top view of the PEAKCOLD Glass Froster with lid open, showing interior rack.

Figure 2.3: Top view of the froster with the sliding lid open, revealing the interior storage area.

Close-up of the glass froster lids.

Figure 2.4: Close-up of the stainless steel sliding lids.

Dimensions of the PEAKCOLD Glass Froster: 26.4 inches depth, 26.4 inches width, 34.25 inches height.

Figure 2.5: Product dimensions: 26.4"D x 26.4"W x 34.25"H.

3. Setup and Installation

3.1 Unpacking

Carefully remove the unit from its packaging. Inspect for any shipping damage. Report any damage to your carrier immediately.

3.2 Placement

  • Place the unit on a strong, level surface.
  • Ensure there is at least 4 inches of clearance on the back and sides for proper ventilation.
  • Avoid direct sunlight or heat sources.

3.3 Caster Installation

The unit comes with wheels for mobility. Attach the casters to the designated points on the bottom of the unit using the provided hardware. Ensure all casters are securely tightened.

3.4 Power Connection

Plug the unit into a dedicated 110V, 60Hz, grounded electrical outlet. Do not use adapters or extension cords.

4. Operating Instructions

4.1 Initial Startup

After installation, allow the unit to sit for at least 2 hours before plugging it in. This allows refrigerants to settle. Once plugged in, the unit will begin cooling to its preset temperature of 0°F (-18°C).

4.2 Temperature Control

This model operates at a fixed temperature of 0°F (-18°C) and does not feature adjustable temperature control.

4.3 Loading Capacity

The froster has a capacity for approximately (90) 8-inch mugs or (85) 10 oz. steins. Arrange items to allow for proper air circulation for optimal frosting.

4.4 Defrost System

The unit features an automatic defrost system, minimizing the need for manual defrosting.

5. Maintenance

5.1 Cleaning the Interior

Regularly clean the interior with a mild soap solution and a soft cloth. Rinse with clean water and dry thoroughly. Do not use abrasive cleaners or sharp objects.

5.2 Condenser Coil Cleaning

The condenser coils should be cleaned every 30 days or as needed to ensure efficient operation. Disconnect power before cleaning. Use a brush or vacuum cleaner to remove dust and debris from the coils located at the back of the unit.

5.3 Door Gasket Maintenance

Inspect door gaskets regularly for cracks or tears. Clean gaskets with warm water and mild soap. Ensure they form a tight seal to maintain temperature.

6. Troubleshooting

Before contacting customer support, review the following common issues and solutions:

ProblemPossible CauseSolution
Unit does not power onNo power supply; tripped circuit breakerCheck power cord connection; reset circuit breaker.
Insufficient coolingPoor ventilation; dirty condenser coils; door not sealed properlyEnsure proper clearance; clean condenser coils; check door gasket.
Excessive noiseUnit not level; fan obstructionAdjust leveling feet; check for obstructions around fan.

If problems persist after attempting these solutions, please contact customer support.

7. Specifications

FeatureDetail
Model NumberIM25GF-B
Exterior Dimensions (D x W x H)26.4" x 26.4" x 34.25"
Interior Dimensions (W x D x H)22" x 23" x 26"
Capacity(90) 8" Mugs or (85) 10 oz. Steins
Temperature0°F (-18°C)
Voltage110 Volts
Defrost SystemAutomatic
Installation TypeFreestanding
Included ComponentsWheels (Casters)
CertificationsETL certified, conforms to NSF std. 7
Item Weight120 Pounds
Annual Energy Consumption306 Kilowatt Hours Per Year

8. Warranty Information

This PEAKCOLD product is covered by the following warranty:

  • Labor: 1 Year
  • Parts: 3 Years
  • Compressor Part: 5 Years

Please retain your proof of purchase for warranty claims. For detailed terms and conditions, refer to the warranty card included with your product or contact customer support.

9. Customer Support

For technical assistance, parts, or warranty inquiries, please contact PEAKCOLD customer support. Have your model number (IM25GF-B) and purchase date available when you call.

Video: This video provides an overview of the customer support experience offered by Iron Mountain Refrigeration & Equipment LLC, the vendor for PEAKCOLD products.

You can also visit the official PEAKCOLD website for additional resources and contact information.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.