Turck BIM-PST-AP6X-V1131

TURCK BIM-PST-AP6X-V1131 Magnetic Field Sensor User Manual

Model: BIM-PST-AP6X-V1131

Brand: Turck

Introduction

This manual provides essential information for the proper installation, operation, and maintenance of the TURCK BIM-PST-AP6X-V1131 Magnetic Field Sensor. Please read this manual thoroughly before using the product to ensure safe and efficient operation.

TURCK BIM-PST-AP6X-V1131 Magnetic Field Sensor

Figure 1: A yellow rectangular magnetic field sensor with an M8 male connector on one end. The sensor body is labeled with 'TURCK', 'BIM-PST-AP6X-V1131/KLP80', and power specifications '10...30 VDC 200 mA'. This image shows the overall appearance of the TURCK BIM-PST-AP6X-V1131 sensor.

Safety Instructions

Always adhere to local and national safety regulations. Disconnect power before installation or maintenance. Do not exceed specified voltage and current ratings. Only qualified personnel should install and service this device.

  • Ensure proper grounding to prevent electrical hazards.
  • Avoid exposing the sensor to extreme temperatures or corrosive environments beyond its specified operating range.
  • Do not modify the sensor in any way, as this may void the warranty and compromise safety.

Setup

Mounting

The BIM-PST-AP6X-V1131 sensor is designed for cylinder position sensing. It should be mounted securely to the cylinder using the provided KLP-80 mounting bracket. Ensure the active face of the sensor is positioned correctly relative to the magnetic field source (e.g., piston magnet).

  1. Identify the optimal sensing position on the cylinder.
  2. Attach the KLP-80 bracket to the cylinder.
  3. Insert the sensor into the KLP-80 bracket and secure it.
  4. Adjust the sensor position for precise detection.

Wiring

This is a 3-wire PNP sensor with an M8 male connector. Connect it to a compatible M8 female cable assembly. Refer to the wiring diagram below for standard PNP connections.

Table 1: M8 Connector Pinout (PNP)
PinColor (Standard)Description
1Brown+VDC (10-30 VDC)
3Blue0 VDC (GND)
4BlackOutput (PNP Normally Open)

Note: Always verify pin assignments with the sensor's datasheet or markings if available, as color codes can vary by region or manufacturer.

Operating

The TURCK BIM-PST-AP6X-V1131 is an inductive magnetic field sensor designed to detect the presence of a magnetic field, typically from a piston magnet within a pneumatic or hydraulic cylinder. When a magnetic field is detected by the front active face, the PNP output will switch to the supply voltage (+VDC).

Functionality

  • Detection: The sensor detects magnetic fields. Its switching point is factory set.
  • Output: The sensor provides a PNP (Positive-Negative-Positive) output. This means the output switches to a positive voltage when activated.
  • Indicator: Many inductive sensors include an LED indicator that illuminates when the sensor detects a target. Observe the sensor for such an indicator to confirm proper operation.

For optimal performance, ensure the magnetic field strength is consistent and the sensor is not exposed to strong external magnetic interference.

Maintenance

The TURCK BIM-PST-AP6X-V1131 sensor is designed for low maintenance. Regular inspection is recommended to ensure continued reliable operation.

  • Cleaning: Keep the sensor's active face clean and free from debris, dust, or excessive moisture. Use a soft, damp cloth for cleaning. Do not use abrasive cleaners or solvents.
  • Cable and Connector Inspection: Periodically check the M8 connector and cable for signs of wear, damage, or corrosion. Ensure the connection is secure.
  • Mounting Security: Verify that the sensor and its KLP-80 mounting bracket remain securely fastened to the cylinder. Vibrations can loosen mounting hardware over time.
  • Environmental Check: Ensure the operating environment remains within the sensor's specified temperature and humidity limits.

No internal user-serviceable parts are present. Do not attempt to open or repair the sensor.

Troubleshooting

If the sensor is not functioning as expected, consider the following common issues and solutions:

Table 2: Troubleshooting Guide
ProblemPossible CauseSolution
Sensor not detecting target / No output
  • No power supply or incorrect voltage.
  • Incorrect wiring.
  • Target (magnet) not within sensing range.
  • Damaged sensor or cable.
  • Verify power supply (10-30 VDC) and connections.
  • Check wiring against the pinout diagram.
  • Adjust sensor position relative to the magnet.
  • Inspect sensor and cable for physical damage. Replace if necessary.
Intermittent detection
  • Loose connection.
  • Vibration affecting mounting.
  • External magnetic interference.
  • Secure all cable connections.
  • Tighten mounting hardware.
  • Relocate sensor or shield from interference if possible.
Sensor always ON/OFF (stuck state)
  • Sensor damaged.
  • Permanent magnetic field present.
  • Test with a known good sensor. Replace if faulty.
  • Ensure no unintended magnetic materials are in the sensing area.

If problems persist after attempting these solutions, contact Turck technical support.

Specifications

Table 3: Product Specifications
AttributeValue
Model NumberBIM-PST-AP6X-V1131
TypeMagnetic Field Sensor, Inductive, Cylinder Position
Output Type3-wire PNP
ConnectionM8 Male Connector
Active FaceFront
Operating Voltage10-30 VDC
Current Consumption200 mA (max)
ManufacturerTURCK
ASINB088C571JQ
Date First AvailableMay 8, 2020

Warranty Information

Turck products are manufactured to high quality standards. For specific warranty terms and conditions, please refer to the official Turck warranty statement available on their website or contact their customer service. Typically, Turck provides a limited warranty against defects in materials and workmanship for a specified period from the date of purchase.

Keep your proof of purchase for warranty claims.

Support

For technical assistance, product inquiries, or warranty claims, please contact Turck customer support:

  • Website: Visit the official Turck website for product datasheets, FAQs, and contact information. (e.g., www.turck.com)
  • Phone: Refer to the Turck website for regional contact numbers.
  • Email: Use the contact forms or email addresses provided on the Turck website.

When contacting support, please have your product model number (BIM-PST-AP6X-V1131) and any relevant purchase details ready.

Related Documents - BIM-PST-AP6X-V1131

Preview TURCK NIMFE-EM12/4.6L88-UP6X-H1141/S1182 Magnetic Field Sensor - Technical Data & Mounting
Detailed technical specifications, features, wiring diagram, functional principle, and mounting instructions for the TURCK NIMFE-EM12/4.6L88-UP6X-H1141/S1182 magnetic field sensor with TIN coating for detecting ferromagnetic parts.
Preview TURCK ...Y1... Magnetic Field Safety Sensors - Safety Manual
Comprehensive safety manual for TURCK's ...Y1... series magnetic field safety sensors. Covers intended use, safety regulations, device specifications, installation, operation, maintenance, and troubleshooting for safety-instrumented systems.
Preview TURCK LI50/B2 Linear Magnetic Position Measurement System Datasheet
Explore the TURCK LI50/B2 Linear Magnetic Position Measurement System, featuring robust die-cast metal housing, compact design, and easy installation. Ideal for industrial automation, this system offers high accuracy and resistance to shock and vibration.
Preview Turck IO-Link All-in-One Solutions for Industry 4.0
This document details Turck's comprehensive IO-Link solutions designed to enable Industry 4.0 communication. It covers the benefits of IO-Link, Turck's product portfolio including sensors, connectivity, and masters, along with application examples and detailed product specifications for various industrial automation components.
Preview TURCK SI3.5-K10-Y1X Inductive Sensor - Slot-type | Technical Data & Operating Instructions
Comprehensive technical specifications, features, functional principle, mounting instructions, and operating guidelines for the TURCK SI3.5-K10-Y1X slot-type inductive sensor. Includes ATEX and SIL2 compliance details.
Preview TURCK MR15-Q80-IOLCJ-H1141 Radar Scanner: Instructions for Use
Comprehensive instructions for the TURCK MR15-Q80-IOLCJ-H1141 Radar Scanner, covering setup, operation, safety, commissioning, and technical specifications for industrial automation applications.