DEPSTECH NTE390

DEPSTECH 3.9mm USB Otoscope Ear Scope Camera User Manual

Model: NTE390

Introduction

Thank you for purchasing the DEPSTECH 3.9mm USB Otoscope Ear Scope Camera. This device is designed to provide a clear visual inspection of the ear canal and other hard-to-reach areas. It features a thin lens, HD camera, and adjustable LED lights for optimal viewing. This manual provides essential information for safe and effective use, setup, operation, maintenance, and troubleshooting.

Safety Information

  • Always use the included heat-proof silicone case when inserting the otoscope into the ear canal to prevent discomfort or injury from heat.
  • Do not force the otoscope into the ear canal. If you feel resistance, stop immediately.
  • Consult a medical professional if you experience pain, discomfort, or notice any abnormalities during use.
  • Keep the device out of reach of children. Adult supervision is required if used on children.
  • Clean the lens and accessories thoroughly before and after each use with the provided alcohol pads.
  • This device is for observation and minor earwax cleaning only. It is not a substitute for professional medical diagnosis or treatment.
A person using the DEPSTECH otoscope with a heat-proof silicone case inserted into their ear, alongside diagrams illustrating safe ear protection versus dangerous insertion without protection.
Image: The heat-proof silicone case ensures safe use by protecting the ear from the device's warmth. Always use the silicone case for ear inspections.

Package Contents

Verify that all items are present in your package:

  • DEPSTECH USB Otoscope Ear Scope Camera (NTE390)
  • Earwax Cleaning Tools (various types)
  • Heat-proof Silicone Case
  • Alcohol Pads
  • User Manual
The DEPSTECH otoscope package contents laid out, including the otoscope, USB cable, alcohol pads, user manual, and various earwax cleaning tools.
Image: All components included in the DEPSTECH NTE390 otoscope package.

Setup

1. Compatibility

The DEPSTECH NTE390 otoscope is compatible with Android 5.0+ devices, Windows PCs, and Mac PCs. It does not support iOS devices.

Diagram illustrating the wide compatibility of the DEPSTECH otoscope with Android 5.0+ devices, Windows PCs, and Type-C devices, noting it does not support iOS.
Image: Compatibility diagram showing supported devices (Android, Windows, Mac) and connection types (Micro-USB, USB, Type-C).

2. App Installation (for Android/PC)

For Android devices, search for and install the application named "Depstech-view" from your device's app store. For Windows/Mac PCs, please refer to the detailed instructions in the included user manual for software download and installation.

3. Connecting the Otoscope

  1. Connect the USB end of the otoscope cable to your Android device (using an appropriate adapter if necessary) or your Windows/Mac PC.
  2. Ensure the connection is secure.
  3. Open the installed "Depstech-view" application or the relevant software on your PC.
  4. The device should be automatically recognized, and the live camera feed will appear on your screen.

Operating Instructions

1. Adjusting LED Lights

The otoscope features adjustable LED lights to provide optimal illumination for clear viewing. Locate the inline controller on the cable. Use the buttons or scroll wheel on the controller to increase or decrease the brightness of the LED lights as needed.

Close-up of the DEPSTECH otoscope cable with an inline controller showing buttons to adjust the LED light intensity, with example ear canal images at different brightness levels.
Image: The inline controller allows for easy adjustment of the LED light intensity.

2. Performing an Inspection

  1. Attach the heat-proof silicone case to the tip of the otoscope.
  2. Gently insert the otoscope into the area you wish to inspect, such as the ear canal. Observe the live feed on your connected device.
  3. Adjust the angle and depth slowly to get a clear view.
  4. Use the application's features to capture photos or record videos of your inspection.
A hand gently using the DEPSTECH otoscope to inspect a baby's ear while the baby sleeps, illustrating its use for children.
Image: The otoscope can be used for gentle inspection of ears, including those of children.

3. Using Earwax Cleaning Tools

The otoscope comes with various earwax cleaning tools. These tools can be attached to the otoscope for assistance in removing soft earwax. Exercise extreme caution when using these tools to avoid injury. Always ensure you have a clear view of the ear canal and the tool's position on your screen.

Warning: Do not use earwax cleaning tools if you are unsure or uncomfortable. Improper use can cause serious injury to the ear drum or canal.

4. Multifunctional Use

Beyond ear inspection, the DEPSTECH NTE390 can be used for inspecting other areas such as the nose, mouth, skin, or even for pet inspection, thanks to its thin lens and clear imaging capabilities.

Six images demonstrating the multifunctional uses of the DEPSTECH otoscope for checking nose, mouth, skin (dermatological), hair, ear observation, and pet inspection.
Image: The otoscope's versatility allows for inspection of various body parts and even pets.

5. Product Overview Video

Video: Official DEPSTECH video demonstrating the features and usage of the NTE390 USB Otoscope Ear Scope Camera.

Maintenance

1. Cleaning the Lens

After each use, especially after ear inspections, gently wipe the otoscope lens with one of the provided alcohol pads. Ensure no residue remains on the lens to maintain clear image quality. Allow the lens to air dry completely before storing.

2. Cleaning Accessories

Wash the earwax cleaning tools with soap and water, then sterilize them with alcohol pads. Ensure they are completely dry before storage. The silicone case can be washed with mild soap and water.

3. Storage

Store the otoscope and its accessories in a clean, dry place, away from direct sunlight and extreme temperatures. Keep it in its original packaging or a protective case to prevent damage.

Troubleshooting

  • No Image/Black Screen: Ensure the otoscope is securely connected to your device. Verify that the correct application/software is open and running. Restart the application or your device if necessary.
  • Blurry Image: Clean the otoscope lens thoroughly with an alcohol pad. Ensure the lens is free of dust, earwax, or smudges. Adjust the focus by slowly moving the otoscope closer or further from the object.
  • LED Lights Not Working: Check the inline controller to ensure the lights are turned on and brightness is adjusted. If the issue persists, try connecting to a different USB port or device.
  • Device Not Recognized: Ensure your device's operating system (Android 5.0+, Windows, Mac) is supported. Try connecting to a different USB port. Reinstall the application/software.
  • Overheating: It is normal for the metal parts to get slightly warm during extended use. Always use the silicone case for ear inspections to prevent direct contact with warm surfaces. If the device becomes excessively hot, discontinue use and allow it to cool down.

Specifications

FeatureSpecification
ModelNTE390
Lens Diameter3.9mm
Light Source TypeLED (6 Adjustable)
Real Angle of View70 Degrees
Voltage5 Volts
MaterialPlastic
Item Weight1.58 ounces
Compatible DevicesPersonal Computer, Smartphone, Tablet (Android 5.0+, Windows, Mac)
Power SourceBattery Powered (via connected device)

Warranty and Support

DEPSTECH products come with a standard manufacturer's warranty. For detailed warranty information, product support, or technical assistance, please refer to the official DEPSTECH website or contact their customer service directly. Contact information can typically be found in the product packaging or on the manufacturer's website.

Related Documents - NTE390

Preview DEPSTECH DS590 Industrial Endoscope User Manual
User manual for the DEPSTECH DS590 Industrial Endoscope, covering features, operation, specifications, and compliance information for industrial inspection.
Preview DEPSTECH DS620 Industrial Endoscope User Manual
User manual for the DEPSTECH DS620 Industrial Endoscope, detailing its features, operation, and specifications. Includes multi-language support.
Preview DEPSTECH DS350DL Dual Lens Endoscope Operation Guide
Comprehensive guide to operating the DEPSTECH DS350DL Dual Lens Endoscope, covering photo/video capture, viewing, deletion, screen rotation, lens switching, TF card formatting, and file transfer.
Preview DEPSTECH DS320 Industrial Endoscope User Manual
Comprehensive user manual for the DEPSTECH DS320 industrial endoscope, covering features, operation, specifications, and troubleshooting. Learn how to use your high-performance inspection camera.
Preview DEPSTECH DS520 Industrial Endoscope User Manual
Comprehensive user manual for the DEPSTECH DS520 industrial endoscope, detailing features, operation, specifications, and troubleshooting for effective visual inspection in industrial and mechanical applications.
Preview DEPSTECH NTC55 Industrial Endoscope User Manual
Comprehensive user manual for the DEPSTECH NTC55 industrial endoscope. Learn about its features, safety guidelines, app usage, specifications, and troubleshooting tips for effective industrial inspection.