Bofa AD-Oracle iQ 30811022-1275

Bofa AD-Oracle iQ 30811022-1275 Laser Fume Extractor User Manual

Model: AD-Oracle iQ 30811022-1275

1. Introduction

This manual provides essential information for the safe and efficient operation, installation, and maintenance of your Bofa AD-Oracle iQ 30811022-1275 Laser Fume Extractor. Please read this manual thoroughly before using the product and retain it for future reference.

Bofa AD-Oracle iQ Laser Fume Extractor unit

Figure 1: A black, rectangular Bofa AD-Oracle iQ Laser Fume Extractor unit with a control panel on top, featuring a digital display and buttons. The unit is equipped with casters for mobility.

The Bofa AD-Oracle iQ is a high-performance laser fume extraction system designed to capture and filter airborne contaminants generated during laser processing applications, such as welding. It features an intelligent iQ operating system for real-time information and easy control, combined HEPA and gas filtration, and automatic voltage detection for versatile use.

2. Safety Information

Always observe the following safety precautions to prevent injury and damage to the equipment:

  • Ensure the unit is properly grounded before operation.
  • Do not operate the unit with damaged power cords or plugs.
  • Always disconnect power before performing any maintenance or filter changes.
  • Ensure adequate ventilation around the unit to prevent overheating.
  • Do not block the air intake or exhaust vents.
  • Use only genuine Bofa replacement filters to maintain performance and warranty.
  • Keep hands and loose clothing away from moving parts.
  • Refer to local regulations for proper disposal of used filters.

3. Product Overview and Features

The Bofa AD-Oracle iQ 30811022-1275 is engineered for effective fume extraction with advanced features:

  • iQ Operating System: Provides real-time information visibility and simplifies operation.
  • Filter Technology: Utilizes reverse flow filter technology with a combined HEPA and gas filter for comprehensive air purification. Advanced carbon filter technology is also integrated.
  • Automatic Voltage Detection: Supports a wide range of input voltages (90V - 257V).
  • Control and Monitoring: Features 24V start/stop, filter change/system error messages, filter status warning, remote control capability, and USB diagnostics.
  • Flow Control: Automatic flow control ensures consistent performance.
  • Display: High-contrast display for clear visibility of operational parameters.
  • Data Logging: Includes a data cache for downloading power and operating parameters.
  • Mobility: Equipped with casters for easy relocation.

4. Setup

  1. Unpacking: Carefully remove the fume extractor from its packaging. Inspect for any shipping damage.
  2. Placement: Position the unit on a stable, level surface. Ensure there is sufficient space around the unit for airflow and maintenance access. The integrated casters allow for easy positioning.
  3. Ducting Connection: Connect the appropriate ducting from your laser processing equipment to the fume extractor's inlet port. Ensure all connections are secure and airtight to prevent leaks.
  4. Power Connection: Connect the power cord to a suitable electrical outlet. The unit features automatic voltage detection (90V - 257V).
  5. Initial Filter Check: Verify that all filters are correctly installed and seated before first use. Refer to the maintenance section for filter installation details.
  6. Remote Control/USB (Optional): If using the remote control or USB diagnostics, connect them according to the accessory instructions.

5. Operating Instructions

  1. Power On: Press the power button on the control panel. The iQ operating system display will illuminate.
  2. System Check: The system will perform a self-check. Monitor the display for any error messages or filter status warnings.
  3. Start Fume Extraction: Initiate the fume extraction process. This can be done via the control panel, the 24V start/stop signal from the laser, or the remote control.
  4. Monitor Operation: During operation, the iQ system provides real-time information. Ensure the automatic flow control is maintaining optimal extraction.
  5. Power Off: To stop extraction, press the power button. The unit will shut down.
  6. Data Download (Optional): If needed, connect a USB device to download operating parameters and analysis data from the internal cache.

6. Maintenance

Regular maintenance is crucial for optimal performance and longevity of your fume extractor.

6.1 Filter Replacement

The iQ system will provide a filter status warning when filters need replacement. Always use genuine Bofa replacement filters.

  1. Disconnect Power: Turn off the unit and unplug it from the power source.
  2. Access Filters: Open the access panel(s) to the filter compartment.
  3. Remove Old Filters: Carefully remove the used combined HEPA and gas filter. Place it in a sealed bag for proper disposal according to local regulations.
  4. Install New Filters: Insert the new filters, ensuring they are correctly oriented and securely seated.
  5. Close Panel: Close and secure the filter access panel(s).
  6. Reset Filter Warning: Follow the instructions on the iQ display to reset the filter status warning.

6.2 Cleaning

  • Wipe the exterior of the unit with a damp cloth. Do not use abrasive cleaners or solvents.
  • Periodically check and clean the air intake and exhaust vents to ensure unobstructed airflow.

7. Troubleshooting

This section addresses common issues you might encounter.

  • Unit Not Powering On:
    • Check if the power cord is securely plugged into both the unit and the electrical outlet.
    • Verify the power outlet is functional.
    • Check for tripped circuit breakers.
  • Reduced Airflow:
    • Check the filter status warning on the iQ display; filters may need replacement.
    • Inspect ducting for blockages or leaks.
    • Ensure intake and exhaust vents are clear.
  • Error Message on Display:
    • Note the specific error code or message. Refer to the iQ system's internal help or contact Bofa support with the error details.
  • Unusual Noise:
    • Ensure the unit is on a stable, level surface.
    • Check for any loose components or foreign objects inside the unit (after disconnecting power).

If problems persist after attempting these solutions, contact Bofa customer support.

8. Specifications

AttributeValue
BrandBofa
Model Number30811022-1275
ColorBlack
Product Dimensions (L x W x H)97.5 x 45.5 x 50.5 cm
Item Weight1.25 Kilograms
Voltage115 Volts, 230 Volts, 24 Volts
Rated Motor Power1.1 kW
Rated Current12.5 A
Sound Level60 dB
Special FeatureHEPA
Filter TypeHEPA Filter
Power SourceCorded Electric
Included ComponentsLaser Fume Extractor Unit
Wireless?No
Recommended Uses for ProductWelding Applications
ManufacturerBofa
Manufacturer Reference30811022-1275
Spare Parts AvailabilityInformation unavailable

9. Warranty and Support

For detailed warranty information, please refer to the documentation provided with your purchase or contact your authorized Bofa distributor. Warranty terms typically cover manufacturing defects for a specified period.

For technical support, spare parts, or service inquiries, please contact Bofa customer service or your local Bofa representative. Ensure you have your model number (AD-Oracle iQ 30811022-1275) and purchase date available when contacting support.

Related Documents - AD-Oracle iQ 30811022-1275

Preview BOFA AD 350 User Manual - Fume Extraction System
Comprehensive user manual for the BOFA AD 350 fume extraction unit, detailing installation, operation, maintenance, and specifications. Learn how to safely and effectively use your BOFA fume extraction system for industrial applications.
Preview BOFA AD Base 1 Oracle User Manual: Operation, Maintenance, and Specifications
Comprehensive user manual for the BOFA AD Base 1 Oracle fume extraction system, covering installation, operation, maintenance, safety, and technical specifications. Learn how to set up, use, and maintain your extraction unit for optimal performance.
Preview BOFA PrintPRO Universal Fume Extraction System Datasheet
Technical datasheet for the BOFA PrintPRO Universal fume extraction system, designed for Roland LEC, LEJ, and LEJ flatbed printers. Features include HEPA filtration, advanced carbon filters, VOC sensors, auto-sensing voltage, and various optional accessories.
Preview BOFA AD Access Fume Extraction System - Technical Datasheet
Detailed technical specifications, features, and part numbers for the BOFA AD Access fume extraction system, designed for light duty laser marking, coding, and engraving applications.
Preview BOFA 2022 Product Range: Fume Extraction Technology
Explore the 2022 product range from BOFA, a world leader in portable fume extraction and filtration technology. Discover solutions for laser, electronics, printing, additive manufacturing, mechanical engineering, dental, pharmaceutical & medical, and beauty industries.