PeakTech P 4095

PeakTech 4095 Digital Bench Multimeter User Manual

Model: P 4095

Brand: PeakTech

1. Introduction

The PeakTech 4095 is a newly developed, high-precision digital bench multimeter designed for professional use. It features a graphical TFT display for high-resolution visualization of measured values, trend curves, function graphs, and more. Capable of up to 150 measurements per second, this device incorporates advanced technical standards and a wide array of special functions, making it an indispensable tool for accurate electrical measurements and data analysis.

This manual provides comprehensive instructions for the safe and efficient operation, setup, maintenance, and troubleshooting of your PeakTech 4095 Digital Bench Multimeter. Please read it thoroughly before using the device.

2. Package Contents

Please check the contents of your package to ensure all items are present and undamaged:

  • PeakTech 4095 Digital Bench Multimeter
  • Power Cable
  • Interface Cable (USB/RS-232)
  • CD-ROM (with software and manual)
  • Test Leads
  • Temperature Sensor
  • User Manual (on CD-ROM)

If any items are missing or damaged, please contact your supplier immediately.

3. Safety Information

Always adhere to the following safety precautions to prevent personal injury or damage to the device:

  • This device complies with safety standards EN 61010-1; CAT I 1000V / CAT II 600 V.
  • Do not exceed the maximum input values for any measurement range.
  • Ensure the device is properly grounded before operation.
  • Do not operate the device if it appears damaged or if the insulation is compromised.
  • Use only the specified test leads and accessories.
  • Avoid contact with live circuits.
  • Do not use the device in wet or damp environments.
  • Disconnect power before cleaning or servicing the device.

4. Product Features

The PeakTech 4095 offers a comprehensive set of features for precise and versatile measurements:

  • Graphical TFT Display: 4 1/2 digit (60,000 counts) 4-inch display (480x320 pixels) for high-resolution data visualization.
  • High Measurement Speed: Up to 150 measured values per second.
  • True RMS Measurement: Accurate True RMS measurements up to 100 kHz, depending on the measurement function.
  • Data Logger: Internal memory for up to 1 million points or external logging to a USB stick for up to 100 million points, with a 5 ms interval.
  • Dual Measurement Function: Simultaneously measure two different functions.
  • Advanced Display Modes: Histogram, Barometer, Trend display, Pass/Fail function.
  • Measurement Functions: DCV, ACV, DCA, ACA, Resistance, Frequency, Capacitance, Diode Test, Continuity Test, Temperature.
  • Temperature Measurement: Supports 2- or 3-wire resistance/thermocouple measurements via types B/E/J/K/N/R/S/T or PT100/PT385.
  • Connectivity: RS-232, LAN network connection, and USB interfaces for PC control and data retrieval via SCPI protocol.
  • Range Selection: Automatic and manual range selection.
  • Additional Functions: AVG, MIN/MAX, and relative value measurement.

PeakTech 4095 Digital Bench Multimeter front viewFigure 1: Front view of the PeakTech 4095 Digital Bench Multimeter.

PeakTech 4095 Digital Bench Multimeter front panel with graphical displayFigure 2: Close-up of the PeakTech 4095 front panel showing the graphical TFT display in trend mode.

PeakTech 4095 Digital Bench Multimeter rear panel with connection portsFigure 3: Rear panel of the PeakTech 4095, displaying the power input, LAN, USB, RS-232, and auxiliary ports.

PeakTech 4095 Digital Bench Multimeter in a laboratory settingFigure 4: The PeakTech 4095 Digital Bench Multimeter in a typical laboratory or workshop environment, connected for measurement.

5. Setup

Follow these steps to set up your PeakTech 4095 Multimeter:

  1. Unpacking: Carefully remove the multimeter and all accessories from the packaging. Retain the packaging for future storage or transport.
  2. Power Connection: Locate the power input on the rear panel. Ensure the voltage selector switch (110V/240V) matches your local power supply. Connect the provided power cable to the multimeter and then to a suitable AC outlet.
  3. Initial Power On: Press the power button on the front panel. The TFT display should illuminate, and the device will perform a self-test.
  4. Connecting Test Leads: Insert the red test lead into the 'HI' input terminal and the black test lead into the 'LO' input terminal for most voltage, resistance, and frequency measurements. For current measurements, refer to the specific input terminals (e.g., 10A, mA/µA).
  5. Interface Connection (Optional):
    • USB: Connect the USB cable from the multimeter's rear USB port to your computer.
    • RS-232: Connect the RS-232 cable from the multimeter's rear RS-232 port to your computer's serial port (or a USB-to-serial adapter).
    • LAN: Connect an Ethernet cable from the multimeter's LAN port to your network router or switch.

    Install the provided software from the CD-ROM on your computer to enable remote control and data logging via these interfaces.

6. Operating Instructions

This section outlines the basic operation and various measurement functions of the PeakTech 4095.

6.1 Basic Measurements

  • Voltage (DCV/ACV): Select the desired voltage function (DCV or ACV) using the function buttons. Connect the test leads in parallel to the circuit under test. The display will show the measured voltage.
  • Current (DCA/ACA): Select the desired current function (DCA or ACA). Ensure the test leads are connected to the appropriate current input terminals (e.g., 10A, mA/µA). Connect the multimeter in series with the circuit.
  • Resistance (Ohm): Select the Ohm function. Connect the test leads across the component to measure its resistance. Ensure the circuit is de-energized before measuring resistance.
  • Capacitance: Select the Capacitance function. Connect the test leads across the capacitor. Ensure the capacitor is discharged before measurement.
  • Frequency: Select the Frequency function. Connect the test leads to the signal source.
  • Temperature: Connect the provided temperature sensor or a compatible thermocouple/RTD to the appropriate input terminals. Select the Temperature function and choose the correct sensor type (e.g., Type K, PT100).

6.2 Special Functions

  • Range Selection: Use the 'Range' button to switch between auto-ranging and manual ranging. In manual mode, press 'Range' repeatedly to cycle through available ranges.
  • MIN/MAX/AVG: Press the 'Math' button and navigate to MIN/MAX/AVG to display the minimum, maximum, or average values recorded during a measurement session.
  • Relative Measurement: Use the 'Math' button to activate the relative measurement function, which displays the difference between the current reading and a stored reference value.
  • Data Logging: Press the 'Record' button to start/stop data logging. Configure logging parameters (interval, internal/external memory) via the 'Record' menu. Data can be saved to internal memory or an external USB stick.
  • Graphical Display Modes: Use the 'Graph' and 'Dual' buttons to switch between numerical display, trend graphs, histograms, and dual measurement displays.

7. Maintenance

Proper maintenance ensures the longevity and accuracy of your PeakTech 4095 Multimeter.

7.1 Cleaning

Regularly clean the exterior of the device with a soft, damp cloth. Do not use abrasive cleaners or solvents. Ensure no moisture enters the device.

7.2 Fuse Replacement

If the current measurement function fails, the fuse may need replacement. Refer to the specifications for the correct fuse type and rating. Disconnect the power cable and all test leads before attempting to replace the fuse. Fuse access is typically on the rear panel or under a designated cover.

7.3 Calibration

For continued accuracy, periodic calibration by a qualified service center is recommended. Refer to the PeakTech website or contact customer support for calibration services.

8. Troubleshooting

If you encounter issues with your PeakTech 4095, refer to the following common problems and solutions:

ProblemPossible CauseSolution
Device does not power on.No power supply; power cable loose; incorrect voltage selector; blown fuse.Check power cable connection; verify voltage selector setting; check and replace power fuse if necessary.
Incorrect or no readings.Incorrect function selected; test leads not properly connected; circuit issue; out of range.Select correct measurement function; ensure test leads are securely connected; verify circuit integrity; switch to auto-ranging or a higher manual range.
Current measurement not working.Blown current fuse; incorrect input terminal.Check and replace the internal current fuse; ensure test leads are connected to the correct current input (e.g., 10A, mA/µA).
PC software cannot connect.Incorrect interface cable; driver not installed; wrong COM port selected; firewall blocking connection.Ensure correct USB/RS-232/LAN cable is used; install drivers from CD-ROM; verify COM port settings in software; check firewall settings.

If the problem persists after attempting these solutions, please contact PeakTech customer support.

9. Specifications

Detailed technical specifications for the PeakTech 4095 Digital Bench Multimeter:

ParameterSpecification
Display4 1/2 digits (60,000 counts) TFT graphical display, 4" (480x320 pixels)
Measurement SpeedUp to 150 values/second
DC Voltage (DCV)600mV / 6/60/600/1000 V; ± 0.02% + 0.01
AC Voltage (ACV)600 mV / 6/60/600/750 V; ± 0.2% + 0.06 (TRMS Frequency: 20 Hz - 100 kHz)
DC Current (DCA)600µA / 6/60/600 mA / 6/10 A; ± 0.06% + 0.02
AC Current (ACA)60 / 600mA / 6/10 A; ± 0.5% + 0.10 (TRMS Frequency: 20 Hz - 10 kHz)
Resistance (Ohm)600 Ω / 6/60/600 kΩ / 6/60/100 MΩ; ± 0.03% + 0.01
Frequency20 Hz… 1 MHz ± 0.01% + 0.003
Capacitance2/20/200 nF / 2/200 / 10000 µF; ± 1% + 0.5
Temperature (RTD)-200 °C… +660 °C; ± 0.08% + 0.002
Temperature (Type K)-200 °C… +1372 °C; ± 0.5 °C
Data Logger MemoryInternal: 1 million points; External (USB): 100 million points
Operating Voltage110 V / 240 V; 50/60 Hz (switchable)
Dimensions (LxHxD)235 x 110 x 295 mm
Weight3 kg
Safety RatingEN 61010-1; CAT I 1000V / CAT II 600 V
Country of OriginChina

10. Warranty and Support

PeakTech products are manufactured with high quality standards and are subject to strict quality control. This device is covered by a standard manufacturer's warranty against defects in materials and workmanship.

For warranty claims, technical support, or service inquiries, please contact PeakTech customer service or your local distributor. Please have your model number (P 4095) and purchase information ready when contacting support.

For the most up-to-date information, drivers, and software, please visit the official PeakTech website.

Related Documents - P 4095

Preview PeakTech 2510 Power Analyzer User Manual
Comprehensive user manual for the PeakTech 2510 Power Analyzer, detailing its features, specifications, safety precautions, and operating procedures for electrical measurements.
Preview PeakTech 3441/3442 Digital Multimeter Operation Manual
Comprehensive operation manual for PeakTech 3441 and 3442 digital multimeters. Details safety, operation, features like True RMS and Bluetooth (3442), and technical specifications.
Preview PeakTech 1072/1073 Smart Digital-Multimeter Bedienungsanleitung
Umfassende Bedienungsanleitung für die PeakTech 1072 und 1073 Smart Digital-Multimeter. Erfahren Sie mehr über Funktionen, Sicherheitshinweise, Messmodi und technische Spezifikationen für präzise elektrische Messungen.
Preview PeakTech 1072/1073 Smart Digital Multimeter Operation Manual
Comprehensive operation manual for the PeakTech 1072 and 1073 smart digital multimeters, detailing features, safety instructions, and usage guidelines.
Preview PeakTech 2510 Power Analyzer User Manual
User manual for the PeakTech 2510 Power Analyzer, detailing its features, technical specifications, safety instructions, and operating procedures.
Preview PeakTech 2035 Digital Multimeter Operation Manual
Comprehensive operation manual for the PeakTech 2035 Digital Multimeter, covering safety instructions, general information, technical specifications, and measurement functions.