Jectse Jectseyxs7rgb5wp

Jectse 4-20mA PT100 Temperature Sensor Transducer User Manual

1. Product Overview

The Jectse 4-20mA PT100 Temperature Sensor Transducer is designed for accurate temperature measurement and conversion into a standard 4-20mA current signal. Its robust resin-sealed structure ensures shake-proof and temperature-resistant performance, making it suitable for harsh industrial environments. This transducer integrates directly into thermal and thermocouple junction boxes, providing a cost-effective solution for long-distance signal transmission with enhanced anti-interference capabilities.

Jectse 4-20mA PT100 Temperature Sensor Transducer

Figure 1: Jectse 4-20mA PT100 Temperature Sensor Transducer.

2. Key Features

  • Durable Construction: Adopted resin sealing structure for shake-proof and temperature-resistant performance in harsh environments.
  • Signal Output: Directly outputs 4-20mA or 0-10mA signals, improving anti-interference ability for long-distance transmission.
  • High Precision: Offers high accuracy, low power consumption, and stable operation across a wide range of ambient temperatures.
  • Adjustable Range: Features an adjustable range and linear function, with automatic cold-end compensation for thermocouple temperature transmitters.
  • Versatile Application: Can be used as a standalone field installation with thermocouples and thermal resistances, or integrated as a functional module in testing equipment.

3. Installation and Setup

Proper installation is crucial for the accurate and reliable operation of the temperature sensor transducer. Ensure all connections are secure and follow local electrical codes.

3.1 Mounting

The transducer is designed for installation within the junction box of a thermal resistor or thermocouple. Ensure the mounting location is stable and free from excessive vibration.

Angled view of the Jectse temperature sensor transducer

Figure 2: Angled view of the sensor, showing the threaded connection.

3.2 Wiring

Connect the input (thermal Pt100, Cu50, Cu100, or thermocouple K, E, S, B, T, J, N) to the designated terminals. The output is a 4-20mA DC signal. Refer to the wiring diagram provided with your specific thermal resistor or thermocouple for correct connections. Ensure power supply is within the specified range.

Close-up of the electrical connector on the Jectse temperature sensor transducer

Figure 3: Close-up of the electrical connector for wiring.

4. Operation

Once installed and wired correctly, the transducer will automatically convert the temperature reading from the connected sensor into a proportional 4-20mA current signal. This signal can then be transmitted to a control system, PLC, or display unit.

4.1 Range Adjustment

The transducer features an adjustable range. This can typically be configured via a PC or a hand controller, allowing calibration to specific temperature ranges as required by the application. For thermocouple inputs, automatic cold-end compensation ensures accurate readings.

Close-up of the probe tip of the Jectse temperature sensor transducer

Figure 4: Close-up of the sensor probe tip.

5. Maintenance

The Jectse temperature sensor transducer is designed for minimal maintenance due to its robust construction. However, periodic checks are recommended to ensure optimal performance.

  • Cleaning: Keep the exterior of the transducer and the sensor probe clean from dust, dirt, and corrosive substances. Use a soft, dry cloth for cleaning.
  • Connection Check: Periodically inspect all electrical connections for tightness and signs of corrosion.
  • Calibration: Depending on the application and required accuracy, periodic calibration checks against a known standard may be necessary.

6. Troubleshooting

If you encounter issues with your temperature sensor transducer, refer to the following common problems and solutions:

ProblemPossible CauseSolution
No 4-20mA outputNo power supply; Incorrect wiring; Sensor faultCheck power connections; Verify wiring diagram; Test sensor independently.
Inaccurate temperature readingIncorrect calibration; Sensor not properly immersed; Environmental interferenceRecalibrate the transducer; Ensure proper sensor placement; Shield from strong electromagnetic fields.
Unstable output signalLoose connections; Electrical noise; Faulty transducerCheck all connections; Use shielded cables; Replace transducer if necessary.

7. Technical Specifications

SpecificationDetail
Input TypesThermal Pt100, Cu50, Cu100 (two-wire/three-wire/four-wire); Thermocouple K, E, S, B, T, J, N (two-wire)
Output Signal4-20mA DC or 0-10mA DC
Adjustable RangeConfigurable via PC or hand controller
CompensationAutomatic cold-end compensation for thermocouples
ConstructionResin sealing structure, shake-proof, temperature-resistant
Dimensions16 x 3.5 x 4.8 cm
Weight200 g
Model NumberJectseyxs7rgb5wp

8. Warranty and Support

This Jectse product comes with a standard manufacturer's warranty against defects in materials and workmanship. For specific warranty terms, please refer to the documentation included with your purchase or contact Jectse customer support. For technical assistance or support, please visit the official Jectse website or contact their customer service department.