MEAN WELL LRS-200-12

MEAN WELL LRS-200-12 Switching Mode Power Supply User Manual

Model: LRS-200-12 | Brand: MEAN WELL

1. Introduction

The MEAN WELL LRS-200-12 is a high-efficiency, single-output switching mode power supply designed to convert AC input to a stable 12V DC output. With a maximum output power of 204W and a current capacity of 17A, this enclosed power supply is suitable for a wide range of electronic devices requiring reliable 12V power. It features a robust design with built-in protections and a wide operating temperature range, ensuring optimal performance in various industrial and scientific applications.

2. Safety Information

Please read all safety instructions carefully before installation and operation. Failure to comply may result in electric shock, fire, or damage to the unit.

  • Qualified Personnel: Installation and servicing should only be performed by qualified personnel.
  • Input Voltage Selection: Ensure the AC input voltage selection switch is set correctly (115VAC or 230VAC) before connecting to the mains power. Incorrect setting can cause damage to the unit.
  • Proper Grounding: Always connect the protective earth (ground) terminal to a proper ground connection to prevent electric shock.
  • Ventilation: Ensure adequate ventilation around the power supply to prevent overheating. Do not obstruct cooling vents.
  • Protections: This unit includes built-in protections against short circuit, overload, over voltage, and over temperature. If a protection circuit is activated, disconnect power, resolve the issue, and then reconnect power.
  • Environmental Conditions: Do not operate the unit in environments exceeding its specified temperature and humidity ranges.

3. Product Overview

The LRS-200-12 power supply features an enclosed design with screw terminal blocks for secure input and output connections. A voltage selection switch allows for adaptation to different AC mains voltages.

MEAN WELL LRS-200-12 Power Supply with Voltage Selector Switch

Figure 3.1: Top/Side view of the LRS-200-12 power supply, showing the AC input voltage selection switch (red) and terminal blocks.

MEAN WELL LRS-200-12 Power Supply Front View

Figure 3.2: Front view of the LRS-200-12 power supply, highlighting the compact enclosed design.

MEAN WELL LRS-200-12 Power Supply Packaging

Figure 3.3: Packaging for the LRS-200-12 power supply, displaying model information.

4. Setup

4.1. Mounting

The LRS-200-12 is an enclosed power supply designed for integration into systems. Ensure it is mounted in a location that allows for adequate airflow and heat dissipation. Maintain proper clearance around the unit to prevent overheating.

4.2. AC Input Voltage Selection

Before connecting the power supply to the AC mains, verify the position of the voltage selection switch. This switch is typically red and located on the side of the unit (refer to Figure 3.1).

  • For 115VAC input (90-132VAC range), set the switch to 115V.
  • For 230VAC input (180-264VAC range), set the switch to 230V.

CAUTION: Setting the switch incorrectly can cause permanent damage to the power supply and connected equipment.

4.3. Wiring Connections

Connect the input and output wiring to the designated screw terminal blocks.

  • AC Input: Connect the Live (L), Neutral (N), and Earth Ground (GND) wires from your AC source to the corresponding terminals.
  • DC Output: Connect the positive (+V) and negative (-V) terminals to your load. Ensure correct polarity.

Tighten all screw terminals securely to prevent loose connections, which can lead to arcing or intermittent operation.

5. Operating Instructions

Once properly installed and wired, the LRS-200-12 power supply is ready for operation.

  • Power On: Apply AC power to the input terminals. The power indicator LED (if present) should illuminate, indicating normal operation.
  • Output Voltage: The unit provides a fixed 12V DC output. Do not attempt to adjust the output voltage unless specified by the manufacturer for a particular model variant.
  • Load Capacity: Ensure the connected load does not exceed the maximum output current of 17A or the total output power of 204W to prevent overload protection activation.
  • Operating Temperature: The power supply is designed to operate within a temperature range of -30°C to 70°C. Operating outside this range may affect performance and lifespan.

6. Maintenance

The LRS-200-12 power supply is designed for long-term, reliable operation with minimal maintenance.

  • Cleaning: Periodically inspect the unit for dust accumulation, especially around ventilation openings. Disconnect power before gently cleaning with a soft, dry cloth or compressed air.
  • Environmental Checks: Ensure the operating environment remains within the specified temperature and humidity limits. Avoid excessive vibration (unit can withstand 5G vibration test, but continuous high vibration should be avoided).
  • No User-Serviceable Parts: Do not attempt to open or repair the power supply. Refer all servicing to qualified personnel. Opening the unit will void the warranty.

7. Troubleshooting

If the power supply is not functioning as expected, consider the following:

  • No Output Power:
    • Check if AC input power is present and correctly connected.
    • Verify the AC input voltage selection switch is set correctly (115V or 230V).
    • Check for tripped circuit breakers or blown fuses in the AC input line.
  • Intermittent Output / Unit Shuts Down:
    • Overload Protection: Disconnect the load and check if the power supply resumes normal operation. Reduce the load if it exceeds 17A or 204W.
    • Short Circuit Protection: Disconnect the load and check for any short circuits in the output wiring or the connected device.
    • Over Temperature Protection: Ensure adequate ventilation. If the unit is hot, allow it to cool down. Reduce ambient temperature if necessary.
  • Incorrect Output Voltage:
    • Confirm the model is LRS-200-12 for 12V output.
    • Check load regulation; a very high load might cause a slight voltage drop.

If issues persist after troubleshooting, contact MEAN WELL technical support.

8. Specifications

ParameterValue
Model NumberLRS-200-12
Output TypeFixed, Single Output
Output Voltage12 VDC
Output Current17 A
Output Power204 W
Minimum AC Input Voltage90 VAC
Maximum AC Input Voltage264 VAC
Input Frequency47 to 63 Hz
Efficiency (Typ.)87.5%
Line Regulation0.5%
Load Regulation1%
Ripple & Noise (Max)150mV
Input Connector TypeScrew Terminal Block
Output Connector TypeScrew Terminal Block
Minimum Operating Temperature-30 °C
Maximum Operating Temperature70 °C
ProtectionsShort circuit, Overload, Over voltage, Over temperature
Isolation Voltage3000VAC
Weight0.66 kg (660 g)
Dimensions (L x W x H)215 x 115 x 30 mm (approx.)
Safety CertificatesIEC/UL 62368-1, BSMI CNS14336-1, EAC TP TC004

9. Warranty and Support

MEAN WELL products are manufactured to high-quality standards. For warranty information or technical support, please refer to the official MEAN WELL website or contact your authorized distributor. Keep your purchase receipt for warranty claims.

Ask a question about this manual