1. Introduction

The ScopeAround MS450 Digital Otoscope Ear Camera is designed to provide a clear and detailed view of the ear canal and eardrum. This device features a 4.5-inch IPS screen, a high-definition camera with adjustable LED lights, and an intelligent gyroscope for image stabilization. It is intended for personal ear inspection and can assist in monitoring ear health. This manual provides essential information for the safe and effective use of your otoscope.

2. Safety Information

3. Package Contents

Verify that all items are present in the package:

Contents of the ScopeAround MS450 package including the otoscope unit, charging cable, ear spoons, specula, and manual.
Image: The complete package contents of the ScopeAround MS450 Digital Otoscope Ear Camera, showing the main unit, camera probe, various ear cleaning tools, charging cable, and user manual.

4. Product Overview

The MS450 otoscope consists of a main display unit and a connected camera probe. Familiarize yourself with the components and controls:

Diagram of the ScopeAround MS450 Digital Otoscope showing labeled parts and controls.
Image: A detailed diagram illustrating the various parts and control buttons of the ScopeAround MS450 Digital Otoscope, including the charging port, TF card slot, speaker, reset button, stand, microphone, camera probe connector, light control, photo/video button, mode switch, up/down keys, OK button, power button, and settings button.

5. Setup

  1. Charge the Device: Before first use, fully charge the otoscope using the provided USB Type-C cable and a compatible power adapter (not included). The charging port is located on the side of the display unit. A full charge provides over 4 hours of continuous use.
  2. Insert MicroSD Card: Ensure the 32GB MicroSD card is properly inserted into the TF Card Slot. This card is used to store photos and videos.
  3. Attach Camera Probe: Connect the camera probe cable securely to the Camera Probe Connector on the display unit.
  4. Select and Attach Specula/Ear Spoon: Choose an appropriate ear speculum (protective cone) or silicone ear spoon. Gently push it onto the tip of the camera probe until it is secure. Always use a speculum to protect the ear canal.
Image showing the charging port of the ScopeAround MS450 otoscope.
Image: The USB Type-C charging port located on the side of the ScopeAround MS450 display unit, used for recharging the internal battery.
Image demonstrating how to attach a protective ear speculum to the otoscope probe.
Image: Illustration of attaching a protective ear speculum to the otoscope camera probe, highlighting its role in preventing injury during use.

6. Operating Instructions

  1. Power On: Press and hold the Power Button (blue button) for a few seconds until the screen turns on.
  2. Adjust LED Brightness: Use the Light Control Button (sun icon) to cycle through 3 levels of LED brightness to achieve optimal illumination for your ear canal.
  3. Positioning: Gently insert the camera probe into the ear canal. The 4.5-inch IPS screen will display a real-time view. The intelligent directional gyroscope helps stabilize the image, preventing disorientation.
  4. Hands-Free Operation: Utilize the integrated stand on the back of the display unit to position the device on a flat surface, allowing for hands-free viewing and easier manipulation of the probe.
  5. Capture Photos/Videos:
    • Press the Mode Switch Button (M) to switch between photo and video modes.
    • In photo mode, press the Photo/Video Button (camera icon) once to take a picture.
    • In video mode, press the Photo/Video Button once to start recording, and press again to stop.
  6. Review Media: Use the navigation buttons (Up/Down) to browse captured photos and videos. Press the OK button to view a selected item.
  7. Transfer Data: Connect the device to a computer using the USB Type-C cable to transfer photos and videos from the MicroSD card. Alternatively, remove the MicroSD card and insert it into a card reader.
  8. Power Off: Press and hold the Power Button until the screen turns off.
A person using the ScopeAround MS450 otoscope to examine their ear, demonstrating stable image orientation.
Image: A user examining their ear with the ScopeAround MS450, highlighting the stable image orientation provided by the intelligent gyroscope for clear viewing.
The ScopeAround MS450 otoscope with its integrated stand deployed for hands-free use.
Image: The ScopeAround MS450 display unit with its stable stand design, allowing for hands-free operation during ear inspection.

7. Maintenance

Image showing how to clean the otoscope camera probe with a wipe and a cotton swab.
Image: Instructions for cleaning the otoscope probe, demonstrating the use of a soft wipe for the exterior and a cotton swab for the lens area.

8. Troubleshooting

ProblemPossible CauseSolution
Device does not power on.Low battery; device frozen.Charge the device fully. If unresponsive, press the Reset button with a pin.
No image on screen.Camera probe not connected; faulty probe.Ensure camera probe is securely connected. If problem persists, contact support.
Image is blurry.Dirty lens; incorrect focal distance.Clean the camera lens. Ensure the probe is within the optimal focal distance (approx. 1 inch / 2.5 cm).
Cannot take photos/videos.MicroSD card full or not inserted; incorrect mode.Check MicroSD card status and ensure it is inserted. Verify device is in photo or video mode.
LED lights not working.Lights turned off or set to lowest brightness.Press the Light Control Button to adjust brightness levels.

9. Specifications

10. Warranty

ScopeAround products are covered by a limited manufacturer's warranty against defects in materials and workmanship. Please refer to the warranty card included in your package or visit the official ScopeAround website for detailed warranty terms and conditions. Keep your proof of purchase for warranty claims.

11. Support

For technical assistance, troubleshooting, or product inquiries, please contact ScopeAround customer support:

Our US-based after-sales support team is available to assist you.

Related Documents - MS450

Preview ScopeAround WiFi Otoscope Camera User Manual
User manual for the ScopeAround WiFi Otoscope Camera, detailing its features, operation, safety precautions, and maintenance. Compatible with iPhone, iPad, and Android devices.
Preview ScopeAround SA39A Digital Otoscope User Manual
User manual for the ScopeAround SA39A portable, handheld video otoscope camera. This guide covers product description, safety warnings, operation procedures, technical specifications, maintenance, and disposal information.
Preview ScopeAround SA200 Smart Otoscope User Manual
User manual for the ScopeAround SA200 Smart Otoscope, detailing its features, specifications, operation, connectivity, data transfer, troubleshooting, and safety information.
Preview ScopeAround SA39E Digital Otoscope User Manual
User manual for the ScopeAround SA39E digital otoscope, detailing product description, operation procedures, safety warnings, technical specifications, and FCC compliance.
Preview ScopeAround DZ2423 Earwax Cleaner Quick Start Guide | Instructions & Maintenance
Get started quickly with the ScopeAround DZ2423 earwax cleaner. This guide provides step-by-step instructions for filling, operation, modes, and maintenance. Learn how to safely and effectively use your ear irrigator.
Preview ScopeAround DZ2423 Earwax Cleaner User Manual
User manual for the ScopeAround DZ2423 Earwax Cleaner, providing detailed instructions on its features, specifications, operation, cleaning, troubleshooting, and safety warnings for effective earwax removal.