TDRFORCE 1/2 HP

Download PDF
Contents

TDRFORCE 1/2 HP Shallow Well Pump Instruction Manual

Model: 1/2 HP | Brand: TDRFORCE

1. Safety Information

Please read this manual carefully before operating the TDRFORCE 1/2 HP Shallow Well Pump. Failure to follow these instructions may result in property damage, injury, or death. Retain this manual for future reference.

General Safety Precautions

  • Always disconnect the pump from the power supply before performing any maintenance or adjustments.
  • Ensure the pump is installed on a stable, level surface to prevent tipping.
  • Do not operate the pump with damaged electrical cords or plugs.
  • Keep children and unauthorized personnel away from the pump during operation.

Liquid Requirements

This pump is designed for clean liquids without suspended solids and non-aggressive properties. The liquid temperature should be between -20℃ and +40℃ (-4℉ to 104℉). It is not recommended for sand point applications, and care should be taken to avoid pumping sand into the pump body.

Storage Precautions

If the pump will remain unused for an extended period, empty it completely to prevent the formation of deposits or expansion due to frozen water. Frozen water can damage fixing bolts or crack the pump body.

2. Product Overview

The TDRFORCE 1/2 HP Shallow Well Pump is a versatile water pressure booster pump suitable for various applications including household water supply, lawn sprinkler irrigation, and general water transfer. It features an automatic electric control system for efficient operation.

Key Features

  • High Efficiency: Provides effective pressure boosting for various water needs.
  • Powerful Performance: 1/2 HP (370W) motor with a maximum head of 108ft and a maximum flow rate of 14 GPM (840 GPH). Boosts water pressure up to 4 bar (working at a rated output pressure of 1.5 bar).
  • Automatic Electric Control: Starts automatically when water flow is detected and shuts off when dry pumping occurs, based on manufacturer-set data.
  • Easy Installation: Equipped with 1-inch inlet and outlet for simple connection to garden hoses and home water systems. Powered by 110V AC with a standard US plug and 6.5ft cord.
TDRFORCE 1/2 HP Shallow Well Pump

Figure 2.1: Overview of the TDRFORCE 1/2 HP Shallow Well Pump.

3. Components Included

The following components are typically included with your TDRFORCE 1/2 HP Shallow Well Pump:

  • TDRFORCE 1/2 HP Shallow Well Pump unit
  • Check valve (1)
  • Handle (1)
  • Teflon tape (1)
Internal components of TDRFORCE pump

Figure 3.1: Diagram showing internal components such as the oxygen-free copper impeller, pure copper coils, stainless steel rotor, selected bearing, and pressure sensor.

4. Specifications

FeatureSpecification
BrandTDRFORCE
Model Number1/2 HP (JETS-60)
Power SourceCorded Electric
Voltage115 Volts AC
Horsepower0.5 HP
Wattage370 Watts
Maximum Flow Rate14.5 Gallons Per Minute (840 GPH)
Maximum Lifting Height (Head)108 Feet
Maximum Pressure4 Bar (rated output 1.5 Bar)
MaterialStainless Steel (pump body), Acrylic (handle)
Item Weight19.76 pounds
Product Dimensions21 x 9 x 10 inches
Speed2850 RPM

5. Setup

Proper setup is crucial for the efficient and safe operation of your TDRFORCE Shallow Well Pump. Follow these steps for installation:

5.1 Placement

  • Place the pump on a stable, level surface.
  • Ensure the pump is in a location protected from direct weather exposure if not rated for outdoor use, or if extreme temperatures are expected.

5.2 Connecting Water Lines

  • Connect the water source to the 1-inch inlet of the pump.
  • Connect the output hose or plumbing system to the 1-inch outlet of the pump.
  • Use the provided Teflon tape on all threaded connections to ensure a watertight seal and prevent leaks.
  • The included check valve should be installed on the inlet side to help maintain prime.
TDRFORCE pump with inlet and outlet connections

Figure 5.1: The pump showing the inlet and outlet connections for water lines.

5.3 Priming the Pump

Before initial use or after the pump has been emptied, it must be primed:

  1. Locate the priming port, usually a cap or plug on the top of the pump housing.
  2. Remove the priming cap/plug.
  3. Fill the pump casing with water until it overflows from the priming port.
  4. Replace the priming cap/plug securely.

5.4 Electrical Connection

  • Ensure the power supply is 110V AC.
  • Plug the pump's standard US plug into a grounded electrical outlet.
  • The power cord is 6.5ft long. Do not use extension cords unless absolutely necessary and ensure they are rated for outdoor use and the pump's power requirements.
TDRFORCE pump installed with green plumbing pipes

Figure 5.2: Example of a TDRFORCE pump installed with plumbing connections.

6. Operation

The TDRFORCE Shallow Well Pump features an automatic electric control system for ease of use.

6.1 Starting the Pump

  • Once properly primed and connected to power, the pump will automatically start when water flow is initiated (e.g., opening a faucet or sprinkler).
  • The control unit has indicator lights for 'Power on', 'Pump on', and 'Failure'.

6.2 Adjusting Pressure

The pressure screw located behind the controller can be used to adjust the operating pressure. Refer to the pressure gauge on the side of the control unit to monitor the current pressure.

TDRFORCE pump with pressure control unit

Figure 6.1: The pump's control unit with indicator lights and pressure gauge.

7. Maintenance

Regular maintenance ensures the longevity and optimal performance of your pump.

7.1 Winterization/Long-Term Storage

If the pump will be stored for a long period or in freezing conditions, it is essential to drain all water from the pump body to prevent damage from freezing. This also prevents the formation of internal deposits.

7.2 Re-starting After Storage

When starting the pump again after storage, refill it with water and check that the shaft runs freely. This can be done by inserting a screwdriver into the slot on the shaft, located on the fan side, and gently turning it.

7.3 General Cleaning

Keep the exterior of the pump clean and free from debris. Ensure ventilation openings are not obstructed.

8. Troubleshooting

This section provides solutions to common issues you might encounter with your pump.

ProblemPossible CauseSolution
Pump does not startNo power supply
Pump not primed
Motor overheating (failure light on)
Check power connection and circuit breaker
Prime the pump with water
Allow pump to cool down; check for obstructions or dry running
Low water pressure/flowInadequate water supply
Clogged inlet/outlet
Air in the system
Incorrect pressure setting
Ensure sufficient water source
Inspect and clear any blockages
Re-prime the pump
Adjust the pressure screw on the control unit
Water leaks from connectionsLoose connections
Insufficient Teflon tape
Damaged fittings
Tighten all connections securely
Reapply Teflon tape generously
Replace any damaged fittings
Pump runs continuouslyLeak in the system
Check valve malfunction
Pressure sensor issue
Inspect entire plumbing system for leaks
Check or replace the check valve
Contact customer support if sensor is suspected

If you encounter issues not listed here or if the suggested solutions do not resolve the problem, please contact TDRFORCE customer support.

9. Warranty and Support

9.1 Warranty Information

TDRFORCE provides a 180-day warranty for this product. This warranty covers manufacturing defects and ensures the product meets its specified performance under normal use conditions.

9.2 Customer Support

As a professional manufacturer in the home water pump field, TDRFORCE offers both pre-sale and after-sale services. If you have any questions, require technical assistance, or need to make a warranty claim, please contact TDRFORCE customer support through the retailer where the product was purchased or visit the official TDRFORCE website for contact information.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.