AIOMEST AN-1800

AIOMEST AI-1800 Digital Pyrometer User Manual

Model: AN-1800

Important Safety Information

WARNING: This device is an industrial-grade infrared thermometer designed exclusively for measuring the surface temperature of inanimate objects. It is NOT intended for measuring human or animal body temperature. Readings for living beings will not be accurate.

  • Do not point the laser directly at eyes or indirectly off reflective surfaces. This product uses a Class II laser with optical power <0.5mW and wavelength 630~670 um.
  • Do not use the device in environments with explosive gas, vapor, or dust.
  • Keep the device away from electromagnetic fields generated by arc welders or induction heaters.
  • Avoid exposing the device to extreme temperatures, humidity, or direct sunlight for prolonged periods.

Product Overview

The AIOMEST AN-1800 Digital Pyrometer is a high-performance, non-contact infrared thermometer engineered for precise temperature measurement across a wide range of industrial and household applications. Its advanced sensor technology allows for rapid and accurate readings of surface temperatures from a safe distance.

AIOMEST AI-1800 Digital Pyrometer with upgraded sensor features

Image: The AIOMEST AI-1800 Digital Pyrometer highlighting its upgraded sensor, lamp light, temperature alarm, and MAX/MIN/AVG/DIF functions for accurate measurements from a further distance.

Key features include a wide temperature range, a high Distance-to-Spot (D:S) ratio of 50:1 for safe long-distance measurements, and adjustable emissivity for enhanced accuracy on various material surfaces. It is ideal for use in smelting, kilning, pottery firing, food processing, HVAC, and detecting hot/cold spots.

AIOMEST AI-1800 Digital Pyrometer showing wide measuring range

Image: The AIOMEST AI-1800 Digital Pyrometer displaying its wide measuring range from -58°F (-50°C) to 3272°F (1800°C) and high accuracy.

Package Contents

Upon unpacking, please ensure all the following items are present:

  • 1 x AIOMEST AN-1800 Digital Pyrometer
  • 1 x 9V Battery
  • 1 x Screwdriver
  • 1 x Buckle
  • 1 x Zippered Case
  • 1 x User Manual (this document)

Setup

1. Battery Installation

  1. Locate the battery compartment cover on the handle of the device.
  2. Use the provided screwdriver to open the battery compartment.
  3. Insert the included 9V battery, ensuring correct polarity (+/-).
  4. Close the battery compartment cover and secure it with the screw.

2. Attaching the Buckle/Carabiner (Optional)

The device includes a metal screw hole for fixing on a tripod and comes with a carabiner for convenient carrying.

  • To attach the carabiner, simply thread it through the designated loop at the base of the handle.
  • For tripod mounting, screw the device onto a standard tripod mount. (Tripod not included)
AIOMEST AI-1800 Digital Pyrometer showing tripod mount and carabiner attachment

Image: The AIOMEST AI-1800 Digital Pyrometer illustrating its metal screw hole for tripod mounting and the carabiner for attaching to a belt loop or tool shelf.

Operating Instructions

1. Powering On/Off

  • To power on, press the trigger. The display will illuminate.
  • The device features a 30-second auto-off function to conserve battery power.

2. Basic Temperature Measurement

  1. Point the infrared lens towards the target object.
  2. Press and hold the trigger. The laser pointer will activate (if enabled) to indicate the measurement spot.
  3. The temperature reading will be displayed instantly on the screen (response time <250 ms).
  4. Release the trigger to hold the reading on the display.
AIOMEST AI-1800 Digital Pyrometer showing 0.25 second response time and convenient functions

Image: The AIOMEST AI-1800 Digital Pyrometer demonstrating its rapid 0.25-second response time and convenient functions such as auto shut down, data hold, MAX/MIN/AVG, temperature alarm, and adjustable emissivity.

3. Distance-to-Spot Ratio (D:S)

The AN-1800 has a D:S ratio of 50:1. This means that at a distance of 50 units from the target, the measurement spot diameter will be 1 unit. For example, at 500 cm (5 meters) distance, the measurement area is approximately 10 cm in diameter. A higher D:S ratio allows for accurate measurement of smaller areas from a greater distance.

AIOMEST AI-1800 Digital Pyrometer illustrating 50:1 Distance-to-Spot ratio

Image: The AIOMEST AI-1800 Digital Pyrometer demonstrating its 50:1 Distance-to-Spot ratio, allowing measurement of a 10cm area from 500cm away.

4. Unit Selection (Celsius/Fahrenheit)

Press the '℃/℉' button to toggle between Celsius and Fahrenheit temperature units.

5. Backlight and Flashlight

The device features a backlight for the display and a built-in flashlight for improved visibility in low-light conditions. Refer to the device buttons for specific controls.

Emissivity Adjustment

Emissivity (ε) is a measure of an object's ability to emit infrared energy. Different materials have different emissivities, ranging from 0.1 (highly reflective) to 1.0 (perfect emitter). For accurate readings, adjust the emissivity setting on your AN-1800 to match the material being measured.

  • The AN-1800 allows emissivity adjustment from 0.1 to 1.0.
  • Consult a standard emissivity table for common materials (e.g., polished metals have low emissivity, painted surfaces and organic materials have high emissivity).
  • To adjust emissivity, press the 'MODE' button until 'EMS' appears, then use the UP/DOWN buttons to set the desired value.

Advanced Functions

1. MAX/MIN/AVG/DIF Modes

The AN-1800 offers various measurement modes:

  • MAX: Displays the maximum temperature recorded during a continuous scan.
  • MIN: Displays the minimum temperature recorded during a continuous scan.
  • AVG: Displays the average temperature recorded during a continuous scan.
  • DIF: Displays the difference between the maximum and minimum temperatures recorded.

To cycle through these modes, press the 'MODE' button repeatedly while the device is powered on.

2. High/Low Temperature Alarm

Set high and low temperature thresholds. The device will emit an alarm when the measured temperature exceeds the high limit or falls below the low limit.

  • Refer to the device's interface for specific buttons to set the alarm thresholds.
  • This feature is useful for monitoring critical temperature ranges in industrial processes or cooking.

Maintenance

1. Cleaning

  • Wipe the device clean with a soft, damp cloth. Do not use abrasive cleaners or solvents.
  • Keep the infrared lens clean and free of dust or debris to ensure accurate readings. Use a soft brush or compressed air for the lens.

2. Battery Replacement

When the battery indicator appears on the display, replace the 9V battery following the installation steps in the 'Setup' section.

3. Storage

Store the device in its zippered case in a cool, dry place when not in use, away from direct sunlight and extreme temperatures.

Troubleshooting

ProblemPossible CauseSolution
No display/Device won't turn onDead or incorrectly installed batteryReplace the 9V battery, ensuring correct polarity.
Inaccurate readingsIncorrect emissivity setting; Dirty lens; Object too far/too small; Measurement through smoke/steamAdjust emissivity for the target material. Clean the lens. Ensure the target fills the measurement spot. Avoid measuring through obstructions.
Laser not visibleLaser disabled; Bright ambient lightCheck device settings to ensure the laser is enabled. The laser may be difficult to see in bright conditions.
Display shows 'HI' or 'LO'Temperature is outside the device's measurement rangeEnsure the target temperature is within -58℉ to 3272℉ (-50℃ to 1800℃).

If you encounter issues not listed here or if solutions do not resolve the problem, please contact customer support.

AIOMEST AI-1800 Digital Pyrometer showing measurement tips for water and oil

Image: The AIOMEST AI-1800 Digital Pyrometer illustrating measurement tips for liquids like water or oil, advising not to face the sensor lens into smoke and to maintain a measuring angle between 45° and 60°.

Specifications

FeatureSpecification
ModelAN-1800
Temperature Range-58℉ to 3272℉ (-50℃ to 1800℃)
Distance Spot Ratio (D:S)50:1
Emissivity0.1 ~ 1.0 (Adjustable)
Response Time<250 ms
Spectral Response8-14um
Resolution0.1℉ (<1832℉); 1℉ (>1832℉)
Accuracy±3% of readings ±3℃ (-50℃ to 0℃); ±2% of readings ±2℃ (0℃ to 100℃); ±3% of readings ±3℃ (≥100℃)
Repeatability1% of reading or 1℃
Laser TypeClass II, <0.5mW, 630~670 um
Power Source9V Battery
Auto-Off30 seconds
Outer Material TypeStainless Steel
Special FeaturesAlarm, High Accuracy, Non-Contact, MAX/MIN/AVG/DIF modes, Data Hold, Backlight, Flashlight, Circle Laser Position

Warranty and Support

AIOMEST provides a 12-month product quality warranty for the AN-1800 Digital Pyrometer from the date of purchase. We also offer life-long technical support to ensure your satisfaction.

For any product-related inquiries, technical assistance, or warranty claims, please contact our customer support team. We aim to provide a quick response within 24 hours.

Please refer to the contact information provided with your purchase or visit the official AIOMEST website for support details.

© 2023 AIOMEST. All rights reserved.

Related Documents - AN-1800

Preview Pleasant Hearth High Efficiency Wood Stove - Medium Installation and Operation Manual
Comprehensive manual for Pleasant Hearth High Efficiency Wood Stove - Medium (PH1800WS, MWS-1800, WSL-1800-B, WSL-1800, GWS-1800, GWS-1800-B). Covers safe installation, operation, safety warnings, and maintenance.
Preview Manuale d'uso: Gonfiatore Elettrico SCOPREGA GE 1800 Series
Scopri il manuale d'uso completo per la serie di gonfiatori elettrici SCOPREGA GE 1800. Informazioni su installazione, utilizzo, manutenzione e risoluzione dei problemi per modelli come GE 1800 ROMA, EL ed EVO.
Preview Pleasant Hearth High Efficiency Wood Stove - Medium: Installation and Operation Manual
This manual provides detailed installation, operation, and maintenance instructions for the Pleasant Hearth High Efficiency Wood Stove - Medium (Models PH1800WS, MWS-1800, WSL-1800-B, WSL-1800, GWS-1800, GWS-1800-B). Learn how to safely install and use your wood-burning stove.
Preview Manuale d'uso SCOPREGA GE 1800: Pompe Elettriche per Gonfiabili
Scopri il manuale completo per la serie di pompe elettriche SCOPREGA GE 1800. Informazioni dettagliate su modelli ROMA, EL, EVO, installazione, uso, manutenzione e caratteristiche come l'Automatic Refilling System (A.R.S.).
Preview AOBOSI Induction Cooker User Manual FS-IRC111-1800
User manual for the AOBOSI Induction Cooker, Model FS-IRC111-1800. Provides product configuration, safety precautions, operating instructions, cookware selection, maintenance, troubleshooting, and warranty information.
Preview electriQ Electric Designer Radiator with Smart App User Manual
Your guide to the electriQ Electric Designer Radiator with Smart App. Covers installation, operation, Wi-Fi connectivity, app control, safety, and troubleshooting for models like HS24, VS6, and VS8 series.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.