Introduction
The Detecto 6800-AC Portable Bariatric Scale is designed for clinical weighing applications, offering a low-profile design for patient comfort and ease of transport. This manual provides essential information for the proper setup, operation, and maintenance of your scale.
Key features include a 1,000 lb / 450 kg capacity, BMI calculation, EMR/EHR readiness, an integral carrying handle, and a low-profile design for easy patient access.
Product Overview

This image shows the Detecto 6800-AC portable bariatric scale. It features a large, square, low-profile weighing platform with a textured, skid-proof rubber surface. A metal carrying handle is visible on the side of the platform. The digital indicator, connected by a cable, displays '75.0' and has buttons for 'ZERO', 'UNITS', 'LOCK/RELEASE', 'ON/OFF', and 'BMI/ENTER'.
Setup Instructions
- Unpack the Scale: Carefully remove all components from the packaging. Verify that all parts are present: the weighing platform, the model 750 weight display, and the 10 ft (3m) indicator cable.
- Position the Platform: Place the 24-inch (61 cm) square weighing platform on a firm, level surface. Ensure the surface is stable and free from vibrations to guarantee accurate readings.
- Connect the Indicator: Connect the 10 ft (3m) indicator cable from the weighing platform to the model 750 weight display. Ensure the connection is secure.
- Power Supply:
- AC Adaptor: Connect the provided AC adaptor to the indicator and then to a suitable power outlet.
- Battery Power: For portable use, the scale can be powered by 6 AA batteries (not included). Open the battery compartment on the back of the indicator and insert the batteries, observing correct polarity.
- Initial Power On: Press the ON/OFF button on the indicator to power on the scale. Allow a few seconds for the display to stabilize and show "0.0".
Operating Instructions
Basic Weighing Procedure
- Power On: Press the ON/OFF button. Wait for the display to show "0.0".
- Zeroing the Scale: If the display does not show "0.0" when empty, press the ZERO button to reset it.
- Select Units: Press the UNITS button to toggle between pounds (lb) and kilograms (kg). The selected unit will be displayed.
- Weighing: Carefully assist the patient onto the center of the weighing platform. Ensure the patient remains still. The weight will be displayed on the indicator.
- Lock/Release: The LOCK/RELEASE button can be used to hold the displayed weight after the patient steps off, or to release the held weight.
- Power Off: Press the ON/OFF button again to turn off the scale when not in use.
BMI Calculation
The Detecto 6800-AC scale can calculate Body Mass Index (BMI).
- Weigh Patient: Follow the basic weighing procedure to obtain the patient's weight.
- Enter Height: Once the weight is stable, press the BMI/ENTER button. The display will prompt for height input. Use the arrow keys (UP/DOWN) to adjust the height value.
- Confirm Height: Press BMI/ENTER again to confirm the height. The scale will then display the calculated BMI.
Maintenance
- Cleaning: Clean the weighing platform and indicator regularly with a damp cloth and mild, non-abrasive cleaner. Do not use harsh chemicals or immerse the unit in water. Ensure the textured rubber surface is clean to maintain its skid-proof properties.
- Battery Replacement: If using battery power, replace all 6 AA batteries when the low battery indicator appears on the display or if the scale fails to power on. Always replace with new batteries of the same type.
- Storage: When not in use for extended periods, store the scale in a dry, temperate environment. The integral carrying handle facilitates easy transport and storage.
- Inspection: Periodically inspect the indicator cable for any signs of damage or wear. Ensure all connections are secure.
Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Scale does not power on. | No power from AC adaptor; dead batteries; loose cable connection. | Check AC adaptor connection and power outlet. Replace batteries. Ensure indicator cable is securely connected. |
| Inaccurate readings. | Scale not on a level surface; patient movement; external vibrations; debris under platform. | Relocate scale to a firm, level surface. Ensure patient remains still. Remove any obstructions under the platform. |
| Display shows "Err" or other error codes. | Overload; internal malfunction. | Ensure weight does not exceed 1000 lb / 450 kg capacity. Power off and on again. If error persists, contact customer support. |
| Cannot change units. | Unit button not pressed correctly; scale in a locked state. | Press the UNITS button firmly. Ensure the scale is not in a locked mode (press LOCK/RELEASE if necessary). |
Specifications
- Model: 6800-AC
- Capacity: 1,000 lb x 0.2 lb / 450 kg x 0.1 kg
- Platform Dimensions: 24 inches x 24 inches (61 cm x 61 cm) square
- Platform Material: Skid-proof, textured rubber surface
- Item Weight: 45 Pounds
- Indicator Cable Length: 10 ft (3m)
- Power: AC Adaptor (included) or 6 AA batteries (not included)
- Features: BMI Calculation, EMR/EHR Ready, Integral Carrying Handle
- Compliance: OIML EC Class III model available (specific model may vary)
Warranty and Support
For detailed warranty information, please refer to the warranty card included with your product or visit the official Detecto website. Warranty terms and conditions may vary.
If you require technical assistance, parts, or service, please contact Detecto customer support. Contact information can typically be found on the manufacturer's website or in the product packaging.
It is recommended to register your product upon purchase to facilitate warranty claims and receive important product updates.