Ultralux U100048

Ultralux 22 Inch 3 Lamp LED Glass Candle Bathroom Vanity Light Instruction Manual

Model: U100048

Introduction

This instruction manual provides essential information for the safe installation, operation, and maintenance of your Ultralux 22 Inch 3 Lamp LED Glass Candle Bathroom Vanity Light. Please read this manual thoroughly before installation and retain it for future reference.

Ultralux 22 Inch 3 Lamp LED Glass Candle Bathroom Vanity Light, front view

Image: Front view of the Ultralux 22 Inch 3 Lamp LED Glass Candle Bathroom Vanity Light, showcasing its brushed nickel finish and three clear glass shades with internal frosted diffusers.

Safety Information

WARNING: Risk of electric shock. Disconnect power at the circuit breaker or fuse box before installation or servicing. Improper installation can result in electric shock or fire.

  • Always consult a qualified electrician if you are unsure about the installation process.
  • Ensure all electrical connections comply with local codes and ordinances.
  • Do not modify the fixture. Any modifications may void the warranty and create a safety hazard.
  • This fixture is designed for indoor use in damp locations only. Do not expose to direct water spray or submersion.
  • Handle glass components with care to prevent breakage.

Package Contents

Verify that all components are present before beginning installation:

  • Ultralux 22 Inch 3 Lamp LED Glass Candle Bathroom Vanity Light Fixture
  • Mounting Hardware (screws, wire nuts, mounting bracket)
  • Instruction Manual

Specifications

FeatureDetail
BrandUltralux
Model NumberU100048
ColorNickel (Brushed Finish)
MaterialGlass, Metal
Light Fixture FormVanity Light
Room TypeBathroom
Indoor/Outdoor UsageIndoor (Damp Location Approved)
Power SourceAC
Special FeatureDimmable (TRIAC compatible)
Light Source TypeIntegrated LED
Number of Light Sources3
Voltage120 Volts (AC)
Wattage23 watts
Brightness1150 Lumens
Color Temperature3000 Kelvin (Warm White)
Color Rendering Index (CRI)80.00
Average Life50,000 Hours
Mounting TypeWall Mount
Product Dimensions22 x 7.75 x 6.75 inches (Length x Width x Height)
Item Weight7.83 pounds
UPC689749000276
Damp Location Approved Icon

Image: Icon indicating the fixture is approved for damp locations, suitable for bathrooms.

Integrated LED Icon

Image: Icon representing integrated LED technology, meaning no replaceable bulbs are needed.

TRIAC Dimmable Icon

Image: Icon indicating the fixture is compatible with TRIAC dimmers for adjustable light output.

Setup and Installation

This fixture is designed for wall-mount installation over a standard electrical junction box. All necessary mounting hardware is included.

Tools Required (Not Included):

  • Phillips head screwdriver
  • Flathead screwdriver
  • Wire strippers
  • Electrical tape
  • Safety glasses

Installation Steps:

  1. Turn Off Power: Locate the circuit breaker controlling the power to the installation location and turn it OFF. Verify power is off using a voltage tester.
  2. Prepare Mounting: Remove the old fixture (if applicable). Attach the mounting bracket (included) to the junction box using the provided screws. Ensure the bracket is securely fastened.
  3. Electrical Connections: Carefully connect the fixture's wires to the corresponding wires from the junction box using the provided wire nuts:
    • Connect the green or bare copper ground wire from the fixture to the ground wire from the junction box.
    • Connect the white (neutral) wire from the fixture to the white (neutral) wire from the junction box.
    • Connect the black (hot) wire from the fixture to the black (hot) wire from the junction box.
    Ensure all connections are secure and cover wire nuts with electrical tape for added safety.
  4. Mount the Fixture: Carefully tuck all wires into the junction box. Align the fixture's base with the mounting bracket and secure it with the provided screws.
  5. Install Glass Shades: Place the clear glass shades over the frosted diffusers and secure them according to the fixture's design. Ensure they are stable and not loose.
  6. Restore Power: Turn the power back ON at the circuit breaker. Test the light fixture.
Ultralux Vanity Light, back view showing mounting plate and wiring

Image: Rear view of the Ultralux vanity light, illustrating the mounting plate and electrical wiring connections for installation.

Operating Instructions

The Ultralux vanity light features integrated LED technology and is designed for simple operation.

  • Power On/Off: Use your standard wall switch to turn the light fixture on or off.
  • Dimming Function: This fixture is TRIAC dimmable. If connected to a compatible TRIAC dimmer switch (sold separately), you can adjust the brightness of the light. Follow the dimmer switch manufacturer's instructions for proper operation.
  • Light Output: The integrated LEDs provide 1150 lumens of warm white light at a color temperature of 3000K.
Ultralux Vanity Light installed in a modern bathroom over a mirror

Image: The Ultralux vanity light installed above a mirror in a modern bathroom setting, demonstrating its functional and aesthetic integration.

Maintenance

The Ultralux vanity light requires minimal maintenance due to its integrated LED design.

  • Cleaning: To clean the fixture, ensure power is turned off at the circuit breaker. Use a soft, dry, or slightly damp cloth to wipe down the metal finish and glass shades. Do not use abrasive cleaners, solvents, or polishes, as these can damage the finish or glass.
  • LED Longevity: The integrated LEDs have an average life of 50,000 hours and are not user-replaceable. If the LEDs fail, the entire fixture may need replacement.

Troubleshooting

If you encounter issues with your Ultralux vanity light, refer to the following common problems and solutions:

ProblemPossible CauseSolution
Light does not turn on.No power to the fixture.Check the circuit breaker and wall switch. Ensure power is restored.
Loose wire connections.Turn off power at the circuit breaker. Recheck all wire connections inside the junction box.
Light flickers or dims inconsistently.Incompatible dimmer switch.Ensure you are using a TRIAC compatible dimmer switch. Replace if necessary.
Loose wire connections.Turn off power at the circuit breaker. Recheck all wire connections.
Light output is lower than expected.Dimmer setting too low.Adjust the dimmer switch to its maximum setting.
Dust or debris on glass shades.Clean the glass shades as per maintenance instructions.

Warranty and Support

For warranty information, technical assistance, or to report any issues with your Ultralux product, please contact Ultralux customer service. Refer to your purchase documentation or the Ultralux website for contact details.

Please have your model number (U100048) and proof of purchase available when contacting support.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.