Notifier FCM-1 Intelligent Addressable Control Module

User Manual

1. Introduction

The Notifier FCM-1 is an intelligent addressable control module designed for use with Notifier's Fire Alarm Control Panels (FACPs). This module provides a supervised Class A or Class B Notification Appliance Circuit (NAC) for controlling external devices such as horns, strobes, or speakers. It communicates with the FACP using the FlashScan protocol, offering fast and reliable communication.

2. Safety Information

Important Safety Instructions:

  • Installation and servicing must be performed by qualified personnel only.
  • Always disconnect power before installing, servicing, or removing the module.
  • CAUTION: DE-ENERGIZE UNIT PRIOR TO SERVICING. Failure to do so may result in electrical shock or damage to the equipment.
  • Adhere to all local and national electrical codes and regulations.
  • Ensure proper grounding to prevent electrical hazards.

3. Product Overview

The FCM-1 module allows the FACP to switch external power to notification appliances. It includes a built-in isolator to protect the communication loop in case of a short circuit. The module is designed for easy installation and addressing.

Notifier FCM-1 Intelligent Addressable Control Module in packaging

Figure 1: Notifier FCM-1 Intelligent Addressable Control Module, shown in its clear plastic packaging. The module is a light-colored square unit with two small circular openings and the "NOTIFIER by Honeywell" logo. A label on the packaging indicates "FCM-1" and "428101".

Key Features:

  • Intelligent addressable control module.
  • Configurable for Class A or Class B Notification Appliance Circuits (NAC).
  • FlashScan protocol compatible.
  • Built-in short circuit isolator.
  • LED indicator for status.

4. Setup and Installation

Proper installation is critical for the reliable operation of the FCM-1 module. Refer to the specific FACP installation manual for detailed wiring diagrams and compatibility information.

4.1 Addressing the Module

  1. Set the module's address using the rotary switches or programming tool as specified by the FACP manufacturer. Each module on the Signaling Line Circuit (SLC) must have a unique address.
  2. Record the assigned address for system documentation.

4.2 Wiring Instructions

  • Power Supply: Connect the external power supply for the NAC to the designated terminals on the module. Ensure the power supply meets the requirements of the notification appliances.
  • SLC Connection: Connect the SLC wiring from the FACP to the module's input terminals. Observe polarity.
  • NAC Connection: Connect the notification appliances to the module's output terminals. For Class A wiring, ensure a return path to the module. For Class B, an End-Of-Line Resistor (EOLR) is required at the last device.
  • Grounding: Ensure the module and associated wiring are properly grounded according to local codes.

Note: Always verify all connections before applying power to the system.

5. Operating Instructions

The FCM-1 module operates under the control of the connected Fire Alarm Control Panel (FACP). Once properly installed and addressed, the FACP will supervise the NAC and activate the connected notification appliances upon receiving an alarm condition.

5.1 LED Indicator

  • Normal Operation: The LED will flash periodically, indicating normal communication with the FACP.
  • Alarm/Active: The LED will illuminate steadily when the module is activated (e.g., during an alarm).
  • Trouble: Specific flash patterns may indicate trouble conditions. Refer to the FACP manual for detailed trouble codes.

5.2 System Testing

Regular system testing, including the activation of the FCM-1 module and its connected notification appliances, should be performed according to local codes and manufacturer recommendations to ensure proper functionality.

6. Maintenance

The FCM-1 module requires minimal maintenance. Regular inspection and cleaning are recommended as part of the overall fire alarm system maintenance schedule.

  • Visual Inspection: Periodically inspect the module for any signs of physical damage, loose connections, or environmental degradation.
  • Cleaning: If necessary, gently clean the exterior of the module with a soft, dry cloth. Do not use abrasive cleaners or solvents.
  • System Testing: Ensure the module is included in routine system tests to confirm its operational status.

Always de-energize the unit prior to any maintenance or servicing.

7. Troubleshooting

If the FCM-1 module or its connected NAC is not functioning as expected, consider the following common troubleshooting steps:

  • No LED Activity:
    • Verify power supply to the FACP and SLC.
    • Check SLC wiring for breaks or short circuits.
    • Confirm module address is correctly set and unique.
  • Trouble Indication on FACP:
    • Consult the FACP manual for specific trouble codes related to the module's address.
    • Check NAC wiring for open circuits (missing EOLR for Class B, or wire break) or short circuits.
    • Verify external power supply for the NAC is present and correct.
  • Notification Appliances Not Activating:
    • Ensure the FACP is in an alarm state.
    • Check the external power supply for the NAC.
    • Verify wiring to the notification appliances.
    • Test individual notification appliances if possible.

If issues persist, contact qualified service personnel or Notifier technical support.

8. Specifications

AttributeValue
BrandNotifier
ModelFCM-1
Part Number6018009186193
Power SourceCorded Electric (for connected NAC)
Alarm TypeAudible (controls audible devices)
Sensor TypePhotoelectric (refers to compatible detectors, not the module itself)
NAC ConfigurationClass A or Class B

Note: Specifications are subject to change without notice. Refer to the latest product datasheet for the most current information.

9. Warranty Information

Notifier products are typically covered by a limited warranty. For specific warranty terms and conditions, please refer to the official Notifier warranty statement provided with your purchase or visit the Notifier website. Keep your proof of purchase for warranty claims.

10. Support and Contact

For technical assistance, product inquiries, or service, please contact your authorized Notifier distributor or visit the official Notifier website. Ensure you have your product model number (FCM-1) and any relevant system information ready when seeking support.

Notifier by Honeywell
www.notifier.com

© 2023 Notifier. All rights reserved. Information is subject to change without notice.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.