1. Product Overview
The Volteck Lait ARB-902L is a 12W LED wall sconce designed for outdoor use, featuring an integrated motion and light sensor. This product provides efficient illumination and enhanced security for various outdoor areas.
Key Features:
- Durable ABS body construction.
- Poliestirene screens for light diffusion.
- Integrated light and motion sensor for automatic operation.
- High-efficiency integrated LED light source.
- Adjustable light sensitivity.

2. Safety Information
Before installation and operation, please read and understand all safety instructions. Failure to follow these instructions may result in electric shock, fire, or other hazards.
- Always disconnect power at the circuit breaker before installing or servicing the fixture.
- Installation should be performed by a qualified electrician in accordance with all local electrical codes.
- Do not attempt to modify the fixture.
- Ensure the mounting surface is structurally sound and can support the weight of the fixture.
- Keep flammable materials away from the light fixture.
IP Rating: IP44
The ARB-902L has an IP44 rating, indicating protection against solid objects larger than 1mm and splashing water from any direction. This makes it suitable for outdoor use where it may be exposed to rain and dust.

3. Package Contents
Verify that all components are present before beginning installation:
- Volteck Lait ARB-902L LED Wall Sconce with Motion Sensor (1 unit)
- Mounting hardware (screws, anchors)
- Instruction Manual

4. Specifications
| Attribute | Specification |
|---|---|
| Model Number | ARB-902L (47338) |
| Power | 12 W |
| Luminous Flux | 1000 lm |
| Color | Black |
| Power Source | Electric Cable |
| Mounting Type | Wall Mount |
| IP Rating | IP44 |
| Motion Sensor Detection Angle | 160 degrees |
| Motion Sensor Detection Distance | Up to 10 meters (32.8 feet) |
| Lifespan | 25,000 hours |
| Dimensions (L x W x H) | 27.99 x 19.99 x 19.99 cm (11.02 x 7.87 x 7.87 inches) |
| Weight | 600 g |

5. Installation
Follow these steps for proper installation of your Volteck Lait ARB-902L wall sconce:
- Preparation: Turn off power at the main circuit breaker before starting. Ensure the mounting location is suitable for outdoor use and can support the fixture.
- Mounting the Bracket: Use the provided mounting hardware to securely attach the fixture's mounting bracket to the wall. Ensure it is level and stable.
- Wiring: Connect the electrical wires from the wall to the fixture's wires. Typically, this involves connecting live to live, neutral to neutral, and ground to ground. Use appropriate wire connectors and ensure all connections are secure and insulated.
- Attaching the Fixture: Carefully attach the fixture body to the mounted bracket, ensuring no wires are pinched. Secure it with the screws or fasteners provided.
- Adjusting Spotlights: Once mounted, you can adjust the direction of the two LED spotlights to cover the desired area.
- Power On: Restore power at the circuit breaker. The light may turn on briefly as it initializes.

6. Operation
The Volteck Lait ARB-902L features an integrated motion and light sensor for automatic operation.
Motion Sensor Functionality:
The motion sensor detects movement within its range and activates the light. The detection angle is 160 degrees, and the maximum detection distance is 10 meters (approximately 32.8 feet).

Adjusting Light Sensitivity:
The fixture includes an adjustment for light sensitivity. This allows you to set the ambient light level at which the motion sensor becomes active. For example, you can set it so the light only activates when it's dark, or during twilight hours.
- Locate the sensitivity adjustment dial or switch on the fixture (refer to product diagram if available).
- Turn the dial towards '+' for higher sensitivity (activates in brighter conditions) or towards '-' for lower sensitivity (activates only in darker conditions).
7. Maintenance
Regular maintenance ensures optimal performance and longevity of your wall sconce.
- Cleaning: Periodically clean the fixture with a soft, damp cloth. Do not use abrasive cleaners or solvents, as these can damage the finish or plastic components. Ensure power is off before cleaning.
- Inspection: Annually inspect the wiring and mounting for any signs of wear, damage, or loosening. Address any issues promptly.
- LEDs: The integrated LEDs are designed for long life (25,000 hours) and are not user-replaceable. If the LEDs fail, the entire fixture may need replacement.
8. Troubleshooting
If you encounter issues with your Volteck Lait ARB-902L, refer to the following common problems and solutions:
| Problem | Possible Cause | Solution |
|---|---|---|
| Light does not turn on. | No power, faulty wiring, sensor malfunction. | Check circuit breaker. Verify wiring connections. Ensure sensor is not obstructed. Adjust light sensitivity setting. |
| Light stays on continuously. | Sensor sensitivity too high, constant motion detected, faulty sensor. | Adjust light sensitivity to a lower setting. Ensure no constant movement in the detection area. |
| Light turns on during daylight. | Light sensitivity set too high. | Adjust light sensitivity to a lower setting so it only activates in darker conditions. |
| Motion sensor range is poor. | Obstructions, incorrect mounting height, extreme temperatures. | Clear obstructions. Ensure mounting height is appropriate (typically 1.8-2.5m). Sensor performance may vary slightly in extreme cold/heat. |
9. Warranty and Support
The Volteck Lait ARB-902L LED Wall Sconce comes with a 3-year warranty from the date of purchase, covering manufacturing defects. Please retain your proof of purchase for warranty claims.
For technical support or warranty inquiries, please contact your retailer or the manufacturer, Volteck, directly. Refer to the product packaging or Volteck's official website for contact information.