1. Introduction
This instruction manual provides essential information for the safe installation, operation, and maintenance of your Proventa LED IP65 Wet Room Light. This 120cm fixture, equipped with an 18W LED tube, is designed for various environments including wet rooms, garages, gardens, and shops. Please read this manual thoroughly before installation and retain it for future reference.
2. Safety Instructions
- Electrical Safety: Always disconnect the main power supply before attempting any installation, maintenance, or repair work. Installation should be performed by a qualified electrician if you are unsure about electrical wiring.
- Grounding: Ensure the fixture is properly grounded according to local electrical codes.
- Product Modification: Do not modify the product in any way. Unauthorized modifications can lead to electric shock, fire, or product damage and will void the warranty.
- IP65 Rating: The IP65 rating indicates protection against dust ingress and low-pressure water jets from any direction. This fixture is suitable for damp and wet environments but is not designed for submersion in water.
- Handling: Handle the LED tube and fixture with care to avoid damage.
3. Package Contents
Verify that all components are present and undamaged before proceeding with installation:
- 4x Proventa IP65 Wet Room Light Housing
- 4x 18W LED Tube
- Mounting Hardware (screws, wall plugs)
4. Product Overview
The Proventa LED IP65 Wet Room Light is a robust and energy-efficient lighting solution. Key features include its 120cm length, 18W power consumption, 2160 lumens output, 4000K neutral white color temperature, and durable polycarbonate construction. The fixture is designed for easy installation and maintenance.

Image 4.1: Proventa LED IP65 Wet Room Light, showing the full fixture and multiple units. This image displays the overall design and the clear cover of the light.

Image 4.2: Overview of the Proventa LED Wet Room Light, highlighting internal wiring and mounting points. This image illustrates the internal structure and key components for installation.
5. Setup and Installation
Follow these steps for safe and correct installation:
- Prepare for Installation:
- Ensure the main power supply to the installation area is switched off at the circuit breaker.
- Unpack the fixture and verify all components are present and undamaged.
- Mounting the Fixture:
- The fixture can be mounted on ceilings, walls, or suspended. Use the provided mounting hardware.
- Mark the desired drilling points on the mounting surface. Drill holes and insert wall plugs if necessary.
- Secure the fixture's base to the mounting surface using the screws. The ultra-flat design (55mm height) allows for discreet placement.
- Wiring the Fixture:
- Open the fixture's cover. The innovative flip-open cover design allows the cover to remain attached to the housing, simplifying single-person installation or tube replacement.
- Feed the electrical cable (suitable for NYM-J 3x2.5mm²) through the cable gland. Ensure the cable gland is tightened to maintain the IP65 rating.

Image 5.1: Detail of the cable gland, indicating suitability for cables up to NYM-J 3x2.5mm² and a 9mm diameter. This component ensures a secure and waterproof cable entry.
- Connect the electrical wires to the plug-in terminal. The plug-in terminal allows for quick and secure connections: simply insert stripped conductors. To release, press the corresponding buttons.

Image 5.2: Close-up of the plug-in terminal for electrical connection, showing L, N, and ground connections. This terminal simplifies wiring without the need for additional tools.
- Installing the LED Tube:
- Remove any transport protection from the LED tube before insertion.
- Carefully insert the 18W LED tube into the G13 sockets within the fixture. Ensure it is seated correctly and securely.
- Closing the Fixture:
- Close the fixture cover, ensuring it latches securely to maintain the IP65 seal.

Image 5.3: Illustration of the flip-open cover mechanism, allowing the cover to remain attached during installation. This feature facilitates easier access for wiring and tube replacement.
- Final Check:
- Once installation is complete, restore power to the circuit and test the light fixture.
6. Operating Instructions
The Proventa LED Wet Room Light operates by simply connecting it to a switched power supply. Once power is supplied, the LED tube will illuminate. There are no additional controls on the fixture itself.
7. Maintenance
- Cleaning: To clean the fixture, ensure the power is off. Use a soft, damp cloth. Do not use abrasive cleaners, solvents, or harsh chemicals, as these can damage the polycarbonate material or the IP65 seal.
- LED Tube Replacement: The LED tube has an expected lifespan of 25,000 hours. If replacement is necessary, disconnect power, open the fixture cover (refer to Section 5.3), carefully remove the old tube, and insert a new G13 18W LED tube. Ensure the new tube is properly seated before closing the cover and restoring power.
- Inspection: Periodically inspect the fixture for any signs of damage, wear, or compromise to the IP65 seal. If any issues are found, disconnect power and address them promptly.
8. Troubleshooting
- Light Does Not Turn On:
- Check if the power supply to the fixture is active.
- Verify that the LED tube is correctly inserted into its sockets.
- Ensure any transport protection on the LED tube has been removed.
- Inspect wiring connections at the plug-in terminal for secure contact.
- Light Flickers:
- Check all electrical connections for tightness and proper contact.
- Ensure the LED tube is fully seated in its sockets.
- Water or Moisture Inside Fixture:
- Immediately disconnect power.
- Inspect the cable gland and the fixture cover for proper sealing. Ensure the cover is securely latched.
- If the seal is compromised, the IP65 rating may be affected, and the fixture may need professional inspection or replacement.
If problems persist after attempting these troubleshooting steps, consult a qualified electrician.
9. Specifications

Image 9.1: Technical data for Proventa LED Wet Room Light, including light color, beam angle, luminous flux, socket, voltage, and dimensions. This provides a quick reference for key product specifications.
| Feature | Specification |
|---|---|
| Brand | Proventa |
| Model Number | 4251263214048 |
| Power Consumption | 18 Watts |
| Luminous Flux | 2160 Lumens |
| Light Color Temperature | 4000K (Neutral White) |
| Beam Angle | 220° |
| Rated Voltage | 220-240 Volts |
| Socket Type | G13 |
| Protection Rating | IP65 |
| Protection Class | II |
| Housing Material | Polycarbonate (PC) |
| Housing Color | Grey |
| Cover Material | Polycarbonate |
| Dimensions (L x W x H) | 1280 x 64 x 58 mm |
| Weight | 0.8 kg |
| Operating Temperature | -20 to 45 °C |
| Lifespan | 25,000 hours |
| Certification | CE, RoHS |
| Energy Efficiency Class | E (EPREL Database Link) |

Image 9.2: EU Energy Label for LED's Light 600710_02, showing an energy efficiency class of E. This label provides information on the product's energy consumption.
10. Warranty and Support
Specific warranty information for this product is not provided in the available data. For warranty claims or technical support, please contact your retailer or the manufacturer, Proventa, directly. Keep your proof of purchase for any warranty-related inquiries.