1. Introduction

This manual provides essential instructions for the safe installation, operation, and maintenance of your Beghelli 1499L 11W Slim Emergency Lamp, Model 8106/11. This energy-efficient, battery-powered LED lamp is designed to provide reliable emergency lighting, particularly for outdoor ceiling-mounted applications. Please read this manual thoroughly before installation and use, and retain it for future reference.

Beghelli 1499L 11W Slim Emergency Lamp, white rectangular unit with a black mounting base

Figure 1: Beghelli 1499L 11W Slim Emergency Lamp. This image shows the white rectangular lamp unit with its black mounting base, designed for discreet installation.

2. Safety Information

Always observe the following safety precautions to prevent injury or damage to the product:

  • Electrical Safety: Installation must be performed by a qualified electrician in accordance with all local and national electrical codes. Ensure power is disconnected before any installation or maintenance.
  • Product Integrity: Do not modify or disassemble the lamp. Any unauthorized modifications will void the warranty and may pose a safety risk.
  • Environmental Conditions: This lamp is designed for outdoor use. Ensure it is installed in a location protected from extreme weather conditions beyond its IP rating (if specified, otherwise assume standard outdoor protection).
  • Battery Handling: The lamp contains a battery. Do not expose the battery to excessive heat, fire, or puncture. Dispose of batteries according to local regulations.
  • Mounting: Ensure the mounting surface is structurally sound and can support the weight of the lamp.

3. Setup and Installation

Follow these steps for proper installation:

  1. Unpacking: Carefully remove the emergency lamp and all components from the packaging. Inspect for any signs of damage. If damaged, do not proceed with installation and contact your supplier.
  2. Tools Required: Gather necessary tools, which typically include a drill, screwdriver, wire strippers, and appropriate mounting hardware (not always included).
  3. Mounting Location: Select a suitable outdoor ceiling location for installation. Ensure the area is clear and provides adequate illumination coverage when the lamp is active. The lamp is designed for ceiling mounting.
  4. Power Disconnection: Before beginning any electrical work, ensure the main power supply to the installation area is completely disconnected at the circuit breaker.
  5. Mounting the Base: Securely attach the lamp's mounting base to the chosen ceiling location using appropriate screws and anchors. Ensure the base is firmly fixed.
  6. Electrical Connection: Connect the lamp's wiring to the building's electrical supply according to the wiring diagram provided with the product (if applicable) and local electrical codes. This lamp is battery-powered, but requires a constant power supply for charging and automatic operation.
  7. Lamp Attachment: Once wiring is complete and secure, attach the main lamp unit to the mounted base. Ensure it clicks or locks into place firmly.
  8. Initial Charge: After installation, restore power to the circuit. The lamp will begin charging its internal battery. Allow at least 24 hours for the battery to achieve a full charge before conducting the first operational test.

4. Operation

The Beghelli 1499L 11W Slim Emergency Lamp operates automatically:

  • Normal Mode: When the main power supply is active, the lamp's battery charges, and the lamp remains off (or in standby, depending on configuration).
  • Emergency Mode: In the event of a power outage, the lamp will automatically switch on, utilizing its internal battery to provide emergency illumination. The lamp is designed to provide light for approximately 8 hours on a full charge.
  • Test Function: The lamp features a tactile switch, typically used for testing the battery and lamp functionality. Press and hold this switch to temporarily simulate a power outage and verify the lamp illuminates. Release the switch to return to normal operation. Perform this test monthly.

5. Maintenance

Regular maintenance ensures optimal performance and longevity:

  • Cleaning: Periodically clean the lamp's exterior with a soft, damp cloth. Do not use abrasive cleaners or solvents. Ensure the lamp is dry before restoring power.
  • Monthly Testing: Conduct a monthly functional test using the tactile switch to ensure the lamp activates and provides light.
  • Annual Discharge Test: Annually, disconnect the main power supply to the lamp for a full discharge test. Allow the lamp to operate on battery power until it fully discharges. Reconnect power and allow 24 hours for a full recharge. This helps maintain battery health.
  • Battery Replacement: The internal battery has a limited lifespan. If the lamp fails to hold a charge or provides significantly reduced illumination time, the battery may need replacement. Due to the specialized nature, contact a qualified technician for battery replacement. Information on spare parts availability is not provided.

6. Troubleshooting

Refer to the table below for common issues and their solutions:

Problem Possible Cause Solution
Lamp does not illuminate during power outage.
  • No power to the unit.
  • Battery not charged.
  • Faulty battery.
  • Internal wiring issue.
  • Check circuit breaker and wiring connections.
  • Allow 24 hours for initial charge.
  • Perform a test using the tactile switch. If it still fails, battery may need replacement.
  • Contact a qualified technician.
Lamp illuminates for a short duration only.
  • Battery not fully charged.
  • Battery nearing end of life.
  • Ensure continuous power supply for charging.
  • Perform an annual discharge test. If performance does not improve, battery may need replacement.
Lamp remains on constantly.
  • Constant power outage.
  • Internal fault.
  • Check main power supply to the building.
  • Disconnect power, wait a few minutes, then reconnect. If issue persists, contact a qualified technician.

7. Specifications

Feature Detail
Brand Beghelli
Model Number 8106/11
Dimensions (L x W x H) 21 x 11 x 30 cm
Weight 570 grams
Material Aluminum
Color White
Style Modern
Finish Type Lacquered
Light Source Type LED
Power Source Battery Powered (with mains charging)
Emergency Operation Duration Approximately 8 hours
Switch Style Tactile (for testing)
Installation Type Ceiling Mount
Usage Environment Outdoor
Energy Efficiency High Energy Efficiency

8. Warranty and Support

For warranty information, please refer to the documentation provided at the time of purchase or contact your retailer. Information regarding the availability of spare parts for this product is not explicitly provided. For technical support or service inquiries, please contact Beghelli customer service or your authorized dealer.

© 2024 Beghelli. All rights reserved. This manual is subject to change without notice.

Related Documents - 8106/11

Preview Beghelli Stile + TR RM Emergency Light Installation and User Manual
Comprehensive guide for installing and operating the Beghelli Stile + TR RM emergency lighting luminaire. Includes technical specifications, wiring diagrams, and safety warnings.
Preview Beghelli EUROCOMPLETA LED Emergency Luminaire Installation Guide
Installation guide and technical specifications for the Beghelli EUROCOMPLETA LED emergency lighting fixture. Learn about assembly, wiring, LED indicators, and model variations.
Preview Beghelli Aestetica LED Emergency Luminaire Installation and Safety Guide
Comprehensive guide for the Beghelli Aestetica LED emergency luminaire, covering installation, wiring, LED indicators, technical specifications, and safety warnings. Includes model details and manufacturer information.
Preview Beghelli Logica LED LG Emergency Lighting Fixture - Installation and Technical Manual
A comprehensive guide to the Beghelli Logica LED LG emergency lighting fixture, covering installation, wiring, technical specifications, LED status indicators, and safety warnings. This manual provides essential information for installers and maintenance personnel.
Preview Beghelli Infinita LED X5 ULTIMATE LG AR Emergency Luminaire Installation and Technical Manual
Comprehensive guide for the Beghelli Infinita LED X5 ULTIMATE LG AR emergency luminaire, detailing installation, technical specifications, testing procedures, LED signal interpretations, and important safety warnings. This manual is designed for installers and maintenance personnel.
Preview Beghelli Completa LED TR Emergency Luminaire Installation and Technical Guide
Installation and technical guide for the Beghelli Completa LED TR emergency LED luminaire. Details IP ratings (IP40, IP42, IP66), wiring, model specifications, operation, and safety warnings.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.