Dyberg Larsen 7087

Download PDFFree PDF. The Save button below keeps a bookmark and private notes in your account.

Dyberg Larsen Cale Floor Lamp User Manual

Model: 7087

1. Introduction

Thank you for choosing the Dyberg Larsen Cale Floor Lamp. This manual provides essential information for the safe and efficient use of your new lamp. The Cale floor lamp features an elegant and minimalist design, crafted from matte white metal, ideal for illuminating various indoor spaces.

Dyberg Larsen Cale Floor Lamp, full view

Image 1.1: Full view of the Dyberg Larsen Cale Floor Lamp.

2. Safety Instructions

  • Read all instructions carefully before assembly and use.
  • This product is designed for indoor use only (IP20 rating). Do not expose to moisture or outdoor elements.
  • Ensure the power supply voltage matches the lamp's requirements (230 Volts).
  • Always disconnect the lamp from the power supply before cleaning, changing the bulb, or performing any maintenance.
  • Use only GU10 bulbs with a maximum wattage of 35W. Exceeding this wattage may cause overheating and damage.
  • Keep the lamp away from flammable materials.
  • Do not attempt to modify the lamp's electrical components. All repairs should be performed by qualified personnel.
  • Ensure the lamp is placed on a stable, level surface to prevent tipping.

3. Package Contents

Please check that all components are present and undamaged:

  • 1 x Dyberg Larsen Cale Floor Lamp (matte white, 15.5 cm diameter shade)
  • Integrated 1.8m white fabric power cable

Note: The GU10 bulb is not included and must be purchased separately.

4. Setup and Assembly

The Dyberg Larsen Cale Floor Lamp is designed for straightforward assembly.

  1. Unpack Components: Carefully remove all parts from the packaging and place them on a clean, soft surface to prevent scratches.
  2. Assemble the Lamp Pole: The lamp pole may come in sections. Gently screw the sections together clockwise until securely tightened.
  3. Attach the Base: Securely attach the lamp pole to the round base. Ensure it is stable and upright.
  4. Install the Bulb:
    • Ensure the lamp is unplugged from the power outlet.
    • Locate the bulb socket within the lamp head.
    • Insert a GU10 bulb (max 35W) into the socket. Push the bulb in and twist clockwise to secure it.
  5. Position the Lamp: Place the assembled lamp in your desired indoor location, ensuring the power cable can reach an outlet without being strained or creating a tripping hazard.
Close-up of the Dyberg Larsen Cale lamp head

Image 4.1: Close-up view of the lamp head, showing the bulb area.

Close-up of the Dyberg Larsen Cale lamp base and cable entry

Image 4.2: Close-up view of the lamp base, illustrating the cable entry point.

5. Operation

Operating your Cale Floor Lamp is simple:

  1. Connect to Power: Plug the lamp's power cable into a suitable 230V electrical outlet.
  2. Turn On/Off: The lamp features a tactile switch located on top of the lamp shade. Gently touch or press the switch to turn the lamp on or off.
  3. Adjust Lamp Head: The lamp head can be rotated to direct the light as desired. Carefully adjust the head to illuminate your preferred area.

6. Maintenance

Regular maintenance ensures the longevity and optimal performance of your lamp.

  • Cleaning: Disconnect the lamp from power. Wipe the lamp with a soft, dry cloth. Do not use abrasive cleaners, solvents, or polishes as they may damage the finish.
  • Bulb Replacement:
    • Ensure the lamp is unplugged and the bulb has cooled down completely.
    • Gently push the GU10 bulb into its socket and twist counter-clockwise to remove it.
    • Insert a new GU10 bulb (max 35W) by pushing it in and twisting clockwise until secure.
  • Cable Inspection: Periodically check the power cable for any signs of damage. If damaged, discontinue use and contact a qualified electrician for repair or replacement.

7. Troubleshooting

If you encounter issues with your Cale Floor Lamp, refer to the following common problems and solutions:

  • Lamp does not turn on:
    • Check if the power cable is securely plugged into the wall outlet.
    • Verify that the wall outlet is functional by plugging in another device.
    • Ensure the GU10 bulb is correctly installed and not faulty. Replace the bulb if necessary.
    • Confirm the tactile switch is being operated correctly.
  • Light flickers:
    • Ensure the bulb is fully seated in the socket.
    • Try a different GU10 bulb to rule out a faulty bulb.

If problems persist after attempting these solutions, please contact Dyberg Larsen customer support.

8. Specifications

FeatureSpecification
BrandDyberg Larsen
Model Number7087
Product Dimensions (L x W x H)15.5 x 15.5 x 135 cm
Item Weight2.7 kg
MaterialMetal (Alloy Steel shade)
ColorMatte White
Bulb BaseGU10
Maximum Wattage35 Watts
Voltage230 Volts
IP RatingIP20 (Indoor use only)
Cable Length1.8 meters (white fabric)
Switch TypeTactile (on lamp shade)
Installation TypeFloor mounted
Bulb IncludedNo
Batteries RequiredNo
Dyberg Larsen Cale Floor Lamp with dimensions indicated

Image 8.1: Dimensional diagram of the Dyberg Larsen Cale Floor Lamp.

9. Warranty and Support

For warranty information or technical support, please refer to the purchase documentation or contact Dyberg Larsen customer service directly. Keep your proof of purchase for any warranty claims.

You can find more information about Dyberg Larsen products on their official website or through authorized retailers.

© 2023 Dyberg Larsen. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.