DAB FEKA 300

DAB FEKA 300 MA Submersible Dirty Water Pump Instruction Manual

Model: FEKA 300 MA

Brand: DAB

1. Introduction

The DAB FEKA 300 MA is a robust submersible pump designed for efficient drainage and lifting of clear, grey, or rainwater in various settings, including domestic and residential environments. This pump is capable of handling moderately dirty water containing solids up to 25mm in diameter. Its versatile design makes it suitable for both fixed and mobile installations. The FEKA 300 MA features an integrated float switch for automatic operation and is engineered to run dry for up to 1 minute without damage.

2. Safety Information

  • Always disconnect the pump from the power supply before any installation, maintenance, or cleaning operations.
  • Ensure the power cable is intact and free from damage. Do not use the pump if the cable is damaged.
  • The pump must be properly grounded.
  • Do not operate the pump in explosive atmospheres or with flammable liquids.
  • Keep children and unauthorized personnel away from the operating area.
  • Ensure the pump is fully submerged during operation to prevent overheating, except for the specified 1-minute dry run capability.

3. Setup

  1. Unpacking: Carefully remove the pump and all accessories from the packaging. Inspect for any signs of damage.
  2. Discharge Connection: Connect a suitable discharge hose to the pump's outlet. Ensure a secure, watertight connection. The pump is designed with a discharge outlet for easy hose attachment.
  3. Float Switch Adjustment: The pump features an integrated float switch for automatic operation. Adjust the cable length of the float switch to set the desired start and stop levels for the pump. The pump will start when the water level rises and lift the float, and stop when the water level drops and the float falls.
  4. Placement: Place the pump on a stable, flat surface in the area to be drained. Ensure the suction grille is clear of obstructions.
  5. Power Connection: Connect the pump to a suitable power outlet. Ensure the power supply matches the pump's requirements (230V ~ 50Hz).
DAB FEKA 300 MA Submersible Dirty Water Pump with dimensions
An image showing the DAB FEKA 300 MA submersible pump. The pump is black and green, with a handle on top and a discharge outlet on the side. Dimensions are indicated: 43cm height, 29cm width (at base), and 21cm depth (at base).

4. Operating Instructions

  1. Automatic Operation: Once connected to power and placed in water, the pump will automatically start when the water level reaches the activation point of the float switch. It will continue to pump until the water level drops below the deactivation point.
  2. Manual Operation (if applicable): If your model supports manual operation (without a float switch or with a manual override), ensure the pump is continuously monitored to prevent dry running for extended periods.
  3. Monitoring: Periodically check the pump's operation and the water level to ensure proper functioning.

5. Maintenance

  • Regular Cleaning: Periodically clean the pump's suction grille to remove any debris, leaves, or solids that may obstruct water intake.
  • Inspection: Regularly inspect the power cable, float switch, and pump body for any signs of wear, damage, or corrosion.
  • Winter Storage: If storing the pump for an extended period, especially in freezing temperatures, ensure it is thoroughly cleaned, drained of all water, and stored in a dry, frost-free location.
  • Professional Service: For any internal repairs or complex issues, contact a qualified service technician.

6. Troubleshooting

  • Pump does not start: Check the power supply, ensure the plug is securely inserted, and verify that the float switch is not stuck in the 'off' position (if applicable).
  • Pump runs but no water is discharged: Check for blockages in the suction grille or discharge hose. Ensure the water level is sufficient for the pump to operate.
  • Reduced flow rate: Clean the suction grille and check the discharge hose for kinks or partial blockages.
  • Pump stops unexpectedly: Check for thermal overload protection activation (allow to cool down). Verify the float switch position.

7. Specifications

FeatureSpecification
ManufacturerDAB PUMPS
Model NumberFEKA 300
Product Dimensions18.9 x 30.3 x 32.9 cm
Item Weight4.6 Kilograms
ColorBlack / Green
StyleSubmersible
Material (Pump Body)Technopolymer
Material (Motor Casing/Shaft)AISI 304 Stainless Steel / AISI 431 Steel
Power SourceCorded Electric
Flow Rate (Min/Max)1 m³/h to 16 m³/h
Max Head7.5 Meters
Max Immersion Depth7 Meters (with adequate cable length)
Liquid TypeWastewater, Dirty Water, Rainwater
Free Passage for Solids25 mm
Minimum Suction Level38 mm
Liquid Temperature (Domestic Use)+0°C to +35°C
Liquid Temperature (Other Uses)+0°C to +50°C
Motor Protection RatingIP 68

8. Warranty and Support

Specific warranty details and support contact information are typically provided with the product packaging or on the manufacturer's official website. Please refer to the documentation included with your purchase for precise warranty terms and conditions. For technical assistance or service inquiries, contact DAB PUMPS customer support.

9. Product Videos

No relevant product videos from the seller were found for this specific model in the provided data. Please refer to the manufacturer's website or product page for any available video resources.

Related Documents - FEKA 300

Preview DAB FEKA 600 Submersible Sewage Pump - Technical Specifications and Performance
Explore the DAB FEKA 600 submersible sewage pump. This document provides comprehensive technical data, performance curves, material specifications, electrical details, and dimensions for domestic wastewater applications.
Preview Guía Rápida de Selección de Bombas DAB: Encuentre la Solución Ideal
Descubra la guía rápida de selección de bombas DAB para aplicaciones domésticas, industriales y de riego. Encuentre la bomba perfecta para sus necesidades de agua, desde suministro hasta gestión de aguas residuales.
Preview NOVA UP MAE - Manuale di Installazione e Manutenzione DAB
Manuale completo per l'installazione, l'uso e la manutenzione della pompa sommergibile DAB NOVA UP MAE. Include dati tecnici, avvertenze di sicurezza e guida alla risoluzione dei problemi.
Preview DAB Pulsar Dry Submersible Pump Quick Start Guide
Concise guide for installing and operating the DAB Pulsar Dry submersible pump, including technical specifications, safety precautions, and connection details.
Preview Manuale di Installazione e Manutenzione DAB DIVERTRON
Guida completa per l'installazione, il funzionamento e la manutenzione delle pompe sommergibili DAB DIVERTRON, inclusi consigli tecnici e risoluzione problemi.
Preview DAB Digital Radio Receiver Controls and Settings
A guide to the controls and settings of a DAB digital radio receiver, including station selection, channel lists, search functions, and system preferences.