1. Introduction
The DAB FEKA 300 MA is a robust submersible pump designed for efficient drainage and lifting of clear, grey, or rainwater in various settings, including domestic and residential environments. This pump is capable of handling moderately dirty water containing solids up to 25mm in diameter. Its versatile design makes it suitable for both fixed and mobile installations. The FEKA 300 MA features an integrated float switch for automatic operation and is engineered to run dry for up to 1 minute without damage.
2. Safety Information
- Always disconnect the pump from the power supply before any installation, maintenance, or cleaning operations.
- Ensure the power cable is intact and free from damage. Do not use the pump if the cable is damaged.
- The pump must be properly grounded.
- Do not operate the pump in explosive atmospheres or with flammable liquids.
- Keep children and unauthorized personnel away from the operating area.
- Ensure the pump is fully submerged during operation to prevent overheating, except for the specified 1-minute dry run capability.
3. Setup
- Unpacking: Carefully remove the pump and all accessories from the packaging. Inspect for any signs of damage.
- Discharge Connection: Connect a suitable discharge hose to the pump's outlet. Ensure a secure, watertight connection. The pump is designed with a discharge outlet for easy hose attachment.
- Float Switch Adjustment: The pump features an integrated float switch for automatic operation. Adjust the cable length of the float switch to set the desired start and stop levels for the pump. The pump will start when the water level rises and lift the float, and stop when the water level drops and the float falls.
- Placement: Place the pump on a stable, flat surface in the area to be drained. Ensure the suction grille is clear of obstructions.
- Power Connection: Connect the pump to a suitable power outlet. Ensure the power supply matches the pump's requirements (230V ~ 50Hz).

4. Operating Instructions
- Automatic Operation: Once connected to power and placed in water, the pump will automatically start when the water level reaches the activation point of the float switch. It will continue to pump until the water level drops below the deactivation point.
- Manual Operation (if applicable): If your model supports manual operation (without a float switch or with a manual override), ensure the pump is continuously monitored to prevent dry running for extended periods.
- Monitoring: Periodically check the pump's operation and the water level to ensure proper functioning.
5. Maintenance
- Regular Cleaning: Periodically clean the pump's suction grille to remove any debris, leaves, or solids that may obstruct water intake.
- Inspection: Regularly inspect the power cable, float switch, and pump body for any signs of wear, damage, or corrosion.
- Winter Storage: If storing the pump for an extended period, especially in freezing temperatures, ensure it is thoroughly cleaned, drained of all water, and stored in a dry, frost-free location.
- Professional Service: For any internal repairs or complex issues, contact a qualified service technician.
6. Troubleshooting
- Pump does not start: Check the power supply, ensure the plug is securely inserted, and verify that the float switch is not stuck in the 'off' position (if applicable).
- Pump runs but no water is discharged: Check for blockages in the suction grille or discharge hose. Ensure the water level is sufficient for the pump to operate.
- Reduced flow rate: Clean the suction grille and check the discharge hose for kinks or partial blockages.
- Pump stops unexpectedly: Check for thermal overload protection activation (allow to cool down). Verify the float switch position.
7. Specifications
| Feature | Specification |
|---|---|
| Manufacturer | DAB PUMPS |
| Model Number | FEKA 300 |
| Product Dimensions | 18.9 x 30.3 x 32.9 cm |
| Item Weight | 4.6 Kilograms |
| Color | Black / Green |
| Style | Submersible |
| Material (Pump Body) | Technopolymer |
| Material (Motor Casing/Shaft) | AISI 304 Stainless Steel / AISI 431 Steel |
| Power Source | Corded Electric |
| Flow Rate (Min/Max) | 1 m³/h to 16 m³/h |
| Max Head | 7.5 Meters |
| Max Immersion Depth | 7 Meters (with adequate cable length) |
| Liquid Type | Wastewater, Dirty Water, Rainwater |
| Free Passage for Solids | 25 mm |
| Minimum Suction Level | 38 mm |
| Liquid Temperature (Domestic Use) | +0°C to +35°C |
| Liquid Temperature (Other Uses) | +0°C to +50°C |
| Motor Protection Rating | IP 68 |
8. Warranty and Support
Specific warranty details and support contact information are typically provided with the product packaging or on the manufacturer's official website. Please refer to the documentation included with your purchase for precise warranty terms and conditions. For technical assistance or service inquiries, contact DAB PUMPS customer support.