SIMPLEX S41006077

SIMPLEX 4100-6077 MX Loop Module Instruction Manual

For 4100ES Fire Alarm Control Panels

Introduction

The SIMPLEX 4100-6077 MX Loop Module is a critical component designed for integration with SIMPLEX 4100ES Fire Alarm Control Panels. This module facilitates the expansion and management of intelligent fire detection and alarm devices within a fire safety system. It provides reliable communication and power distribution for addressable devices on its detection loop, ensuring comprehensive monitoring and rapid response capabilities.

Proper installation, operation, and maintenance of this module are essential for the optimal performance and safety of the entire fire alarm system. This manual provides detailed instructions to assist qualified personnel in these processes.

Safety Precautions

Setup and Installation

The 4100-6077 MX Loop Module is designed for internal mounting within compatible SIMPLEX 4100ES Fire Alarm Control Panels. Follow these steps for proper installation:

  1. Preparation:
    • Ensure the fire alarm control panel is powered off and locked out.
    • Verify that all necessary tools and components are available.
    • Inspect the module for any visible damage before installation.
  2. Mounting the Module:

    Carefully align the module with the designated mounting slots or standoffs within the 4100ES panel chassis. Secure the module using the provided screws or fasteners. Ensure it is firmly seated to prevent vibration or accidental dislodgement.

    SIMPLEX 4100-6077 MX Loop Module mounted vertically

    Image: A close-up view of the SIMPLEX 4100-6077 MX Loop Module, showing its green circuit board with various electronic components, including integrated circuits, capacitors, and resistors. The module is depicted in a vertical orientation, ready for installation into a control panel chassis.

  3. Wiring Connections:

    Connect the loop wiring from the fire alarm devices to the designated terminals on the MX Loop Module. Pay close attention to polarity and ensure all connections are secure and properly insulated. Refer to the 4100ES panel's wiring diagrams for specific terminal assignments.

    SIMPLEX 4100-6077 MX Loop Module with wiring terminals

    Image: The SIMPLEX 4100-6077 MX Loop Module shown horizontally, highlighting the various connection terminals and the intricate layout of its electronic components. This view is useful for identifying wiring points.

  4. Module Addressing and Configuration:

    Once physically installed and wired, the module and its connected devices must be addressed and configured using the 4100ES panel's programming interface. Consult the 4100ES Fire Alarm Control Panel manual for detailed programming instructions.

  5. Power Up and Testing:

    After all connections are verified, restore power to the 4100ES panel. Perform a comprehensive system test to ensure the MX Loop Module is communicating correctly with the panel and all connected devices are functioning as expected.

Operating Principles

The 4100-6077 MX Loop Module serves as an interface between the 4100ES Fire Alarm Control Panel and a loop of intelligent addressable fire detection devices (e.g., smoke detectors, heat detectors, manual pull stations, control modules). It provides the necessary power and communication signals for these devices to operate and report their status to the main panel.

Maintenance

Regular maintenance is crucial for the longevity and reliable operation of the MX Loop Module and the entire fire alarm system. Perform the following checks periodically:

Detailed view of the SIMPLEX 4100-6077 MX Loop Module circuit board

Image: A detailed overhead view of the SIMPLEX 4100-6077 MX Loop Module's circuit board, showcasing the arrangement of various electronic components. This image is useful for identifying specific parts during inspection or troubleshooting.

Troubleshooting

This section provides guidance for common issues encountered with the MX Loop Module. For complex problems, contact SIMPLEX technical support.

ProblemPossible CauseSolution
Module not recognized by panelIncorrect installation, loose connection, module fault, panel configuration error.Verify module seating and connections. Check panel configuration. Replace module if necessary.
Loop fault (open/short circuit)Wiring error, damaged cable, faulty device on loop.Inspect loop wiring for breaks or shorts. Test individual devices. Isolate faulty section.
Intermittent device communicationLoose wiring, electrical interference, device address conflict.Check all connections. Ensure proper shielding. Verify unique device addresses.
Module status LED indicates troubleInternal module fault, power issue.Refer to the 4100ES panel's diagnostic messages. Verify power supply. Contact support.

Specifications

AttributeDetail
Model NumberS41006077
Part Number0743849
DescriptionMX Loop Module
ManufacturerSIMPLEX
Item Weight1.3 pounds (0.59 kg)
Product Dimensions13.5 x 10.5 x 3 inches (34.3 x 26.7 x 7.6 cm)
Power SourceBattery Powered (via 4100ES panel)
ASINB0842Z4PCM
UPC767571882915
Serial Number Example4100-6077|0918190453285683|1

Note: Specifications are subject to change without notice. Always refer to the latest product documentation from SIMPLEX.

Product label for SIMPLEX 4100-6077 MX Loop Module

Image: A close-up of the product packaging label for the SIMPLEX 4100-6077 MX Loop Module. The label displays the PID, description, part number, serial number, and quantity, along with the SIMPLEX logo.

Warranty and Support

SIMPLEX products are manufactured to high standards and are typically covered by a limited warranty. For specific warranty terms and conditions applicable to the 4100-6077 MX Loop Module, please refer to the warranty documentation provided with your purchase or contact SIMPLEX directly.

For technical support, service, or inquiries regarding the 4100-6077 MX Loop Module, please contact your authorized SIMPLEX distributor or SIMPLEX customer service. Provide the model number (S41006077) and any relevant serial numbers (e.g., 4100-6077|0918190453285683|1) when seeking assistance to expedite the support process.

You can also find more information and resources on the official SIMPLEX website.

Related Documents - S41006077

Preview Simplex SPS/RPS Installation Instructions
Installation instructions for Simplex 4100-Series System Power Supplies (SPS) and Remote Power Supplies (RPS), detailing setup, wiring, configuration, and troubleshooting for fire alarm systems.
Preview Simplex Catalog 2023: Fire Alarm Control Units and Systems
Explore the comprehensive Simplex Catalog 2023, featuring a wide range of advanced fire alarm control units, initiating devices, notification appliances, and network solutions from Johnson Controls.
Preview Simplex IDNet Signal IAM Installation Instructions
Detailed installation instructions for the Simplex 4090-9007 IDNet Addressable Signal Individual Adapter Module (Signal IAM), covering address setting, wiring configurations for Class A and Class B Notification Appliance Circuits (NACs), and mounting procedures. This guide provides essential information for integrating the Signal IAM with fire alarm control panels and notification appliances.
Preview Simplex SPS/RPS Installation Instructions
This document provides detailed installation instructions for Simplex SPS (System Power Supplies) and RPS (Remote Power Supplies), covering models 4100-5111, 4100-5112, 4100-5125, 4100-5126, 4100-5113, and 4100-5127. It includes information on wiring, mounting, configuration, and troubleshooting for these fire alarm control panel components.
Preview Simplex Addressable Manual Stations: IDNet/MAPNET II Peripherals
Explore Simplex addressable manual fire alarm stations, detailing their features, single/double action types, NO GRIP options, and compatibility with IDNet/MAPNET II systems. Includes mounting and specification information.
Preview Simplex 4100ES Service Parts List
Official service parts list for the Simplex 4100ES fire alarm system, detailing replacement components, modules, and accessories for maintenance and repair.