Elitech IR-200

Elitech IR-200 Refrigerant Leak Detector User Manual

Model: IR-200

1. Product Overview

The Elitech IR-200 is an advanced refrigerant leak detector designed for HVAC professionals. It integrates both infrared (IR) and heated diode sensor technologies into a single unit, offering superior accuracy and an extended sensor lifespan of up to 10 years. This device is capable of detecting all types of halogenated refrigerants with high sensitivity and features a clear 2.8-inch display for precise leak location.

Elitech IR-200 Refrigerant Leak Detector

Figure 1.1: Elitech IR-200 Refrigerant Leak Detector. This image shows the main unit with its flexible probe, display screen, and control buttons.

Key Features:

Elitech IR-200 Key Features

Figure 1.2: Overview of Elitech IR-200's key features, highlighting its dual sensor, anti-interference design, broad refrigerant detection, and TFT screen.

Elitech IR-200 Infrared and Heated Diode Sensors

Figure 1.3: Detailed view of the Infrared Sensor (top) and Heated Diode Sensor (bottom) components, emphasizing their role in accurate and long-lasting leak detection.

2. Setup

2.1 Unpacking and Initial Inspection

Carefully unpack all components from the product packaging. Verify that all items listed in the 'Package Includes' section (see Figure 2.1) are present and undamaged. If any items are missing or damaged, contact Elitech customer support immediately.

Elitech IR-200 Package Contents

Figure 2.1: Contents included in the Elitech IR-200 package, typically including the leak detector, UV LED, adapter, charging cable, extended probe, plastic case, and replacement filters.

2.2 Charging the Device

Before first use, ensure the device is fully charged. Connect the provided charging cable to the USB Type-C port on the device and plug the adapter into a power outlet. The battery indicator on the display will show charging status.

2.3 Attaching the Probe and UV LED

Attach the flexible probe to the top of the main unit. If required for specific applications, connect the UV LED to its designated port on the probe. The extended probe can be used for reaching difficult areas.

Elitech IR-200 Device Components

Figure 2.2: Labeled diagram of the Elitech IR-200, showing the flexible probe, UV LED, filter components, 3.5mm headphone jack, USB Type-C port, display screen, buttons, buzzer, and extended probe.

3. Operating Instructions

3.1 Powering On/Off

Press and hold the ON/OFF button to power the device on or off. The display will illuminate upon startup.

3.2 Sensor Mode Selection

The IR-200 features two sensor modes: Infrared (IR) and Heated Diode. Press the MODE button to switch between these two sensor types. Each mode offers distinct advantages for different detection scenarios.

Elitech IR-200 Dual Mode Display

Figure 3.1: Display comparison between Infrared mode (left) showing sensitivity bars and Heated Diode mode (right) showing numerical concentration, illustrating the two changeable modes and the 2.8-inch large screen.

3.3 Adjusting Sensitivity

In Infrared mode, press the RESET SENS button to adjust the sensitivity level (High, Medium, Low). Higher sensitivity is ideal for detecting very small leaks, while lower sensitivity helps pinpoint larger leaks without false positives.

3.4 Leak Detection Process

  1. Preparation: Ensure the area is well-ventilated and free from strong air currents that might disperse refrigerant.
  2. Initial Scan: Begin with the Infrared mode at a higher sensitivity setting. Slowly move the probe around suspected leak areas (e.g., joints, fittings, valves).
  3. Pinpointing Leaks: Once a general leak area is identified (indicated by an alarm and visual cues on the display), switch to Heated Diode mode for precise numerical concentration readings. Move the probe slowly to find the highest concentration reading, which indicates the exact leak point.
  4. Peak Function: Press the PEAK button to mark or unmark the maximum leak concentration detected. This helps in tracking the highest reading during the detection process.
  5. Mute Function: Press the MUTE button to silence the audible alarm if needed for a 'quiet' working environment.

Video 3.1: Elitech AI HVAC/R Tools Overview. This video provides a general overview of Elitech's AI-powered HVAC/R tools, including the leak detector, showcasing their features and applications in the field.

3.5 Refrigerant Detection Capabilities

The Elitech IR-200 is designed to detect a comprehensive range of halogenated refrigerants. Refer to the table below for common types:

Elitech IR-200 Refrigerant Compatibility

Figure 3.2: Chart illustrating the types of halogenated refrigerants detectable by the Elitech IR-200, categorized by HFCs, HCFCs, CFCs, PFCs, HFOs, and HCs.

4. Maintenance

4.1 Sensor Replacement

The infrared and heated diode sensors have a long lifespan, but may require replacement over time or if performance degrades. Refer to the device's internal instructions or contact customer support for sensor replacement procedures. Ensure to use only genuine Elitech replacement parts.

4.2 Filter Replacement

Regularly check and replace the filter components on the probe to ensure optimal performance and prevent contamination of the sensors. The package includes 5 replacement filters.

4.3 Cleaning the Device

Wipe the device exterior with a soft, dry cloth. Do not use abrasive cleaners or solvents. Keep the display screen clean and free from scratches.

5. Troubleshooting

5.1 Common Issues and Solutions

ProblemPossible CauseSolution
Device does not power onLow battery; Power button not pressed correctlyCharge the device; Press and hold the ON/OFF button until the display illuminates.
Inaccurate readings or false alarmsContaminated sensor/filter; High background concentration; Incorrect sensitivity settingReplace filter/sensor; Move to a clean air environment and reset sensitivity; Adjust sensitivity level.
No response from buttonsSoftware glitch; Device frozenPower off and restart the device. If issue persists, contact support.
Display is blank or flickeringLow battery; Device malfunctionCharge the device; Contact customer support.

5.2 Contacting Support

If you encounter issues not covered in this section or require further assistance, please contact Elitech customer support. Elitech offers 24/7 customer service and technical support from their US local team.

6. Specifications

SpecificationValue
ModelIR-200
BrandElitech
Item Weight2 Pounds
Product Dimensions (L x W x H)7.9" x 2.8" x 1.4"
Sensitivity3g/yr (0.1oz/yr)
Response TimeImmediate
Working Temperature Range-10°C to 52°C
Batteries1 AAA batteries required (included)
UPC757233348002
CertificationsEN14624, CE
Elitech IR-200 Specifications Diagram

Figure 6.1: Diagram illustrating the physical dimensions, weight, and key performance specifications of the Elitech IR-200.

7. Warranty and Support

7.1 Warranty Information

For detailed warranty terms and conditions, please refer to the warranty card included with your product or visit the official Elitech website. Elitech stands behind the quality of its products.

7.2 Customer Support

Elitech provides comprehensive customer service and technical support. Our US local team is available 24/7 to assist you with any questions or issues regarding your Elitech IR-200. Please visit our official website or refer to the contact information provided in your product packaging for support channels.

Related Documents - IR-200

Preview Elitech IR-200 Infrared & Heated Diode Leak Detector User Manual
Comprehensive user manual for the Elitech IR-200, a dual-sensor leak detector featuring infrared and heated diode technology. Learn about its specifications, operation, maintenance, and features for detecting refrigerant leaks.
Preview Elitech LD-100 Heated Diode Refrigerant Leak Detector User Manual
User manual for the Elitech LD-100 Heated Diode Refrigerant Leak Detector, detailing its features, operation, and maintenance.
Preview Elitech ILD Series Infrared Refrigerant Leak Detector User Manual
Comprehensive user manual for the Elitech ILD series infrared refrigerant leak detectors (ILD-100, ILD-200, ILD-300), covering specifications, operation, maintenance, and features. Learn how to effectively detect refrigerant leaks with this advanced device.
Preview Elitech WJL-6000S Corona Detector User Manual
User manual for the Elitech WJL-6000S Corona Detector, providing detailed instructions on operation, detection, troubleshooting, and maintenance for refrigerant leak detection in various systems.
Preview Elitech ILD-100/ILD-200/ILD-300 Infrared Leak Detector User Manual
User manual for the Elitech ILD series infrared refrigerant leak detectors (ILD-100, ILD-200, ILD-300). Provides detailed information on operation, specifications, features, and maintenance for accurate refrigerant leak detection.
Preview Elitech MS-100 Digital Manifold: User Manual and Specifications
Comprehensive guide to the Elitech MS-100 digital manifold, covering its features, technical specifications, operation, safety instructions, and troubleshooting. Learn how to use the device for pressure and temperature measurements, leak tests, vacuum processes, and data logging with the Elitech Tools app.