Popp THC15A

POPP THC15A Digital Programmable Weekly Timer Switch User Manual

Brand: Popp | Model: THC15A

1. Introduction

This manual provides detailed instructions for the installation, operation, and maintenance of your POPP THC15A Digital Programmable Weekly Timer Switch. This device is designed to automatically control the power supply to electrical appliances based on programmed schedules, offering convenience and energy efficiency. Please read this manual thoroughly before use to ensure proper function and safety.

2. Safety Information

Always observe the following safety precautions to prevent injury or damage to the device:

3. Product Overview

3.1 Features

3.2 Components

POPP THC15A Digital Timer Switch Front View

Figure 1: Front View of POPP THC15A Timer Switch. This image shows the front panel of the timer switch, featuring the LCD display, programming buttons (P, D+, H+, M+), Reset button, Manual button, and the ON indicator light.

POPP THC15A Digital Timer Switch Angled View

Figure 2: Angled View of POPP THC15A Timer Switch. This image provides an angled perspective of the timer, highlighting its compact design and the protective clear cover over the display and buttons.

POPP THC15A Digital Timer Switch Side View

Figure 3: Side View of POPP THC15A Timer Switch. This image displays the side profile of the timer switch, showing its depth and DIN rail mounting clips.

POPP THC15A Digital Timer Switch Back View with Wiring Diagram

Figure 4: Back View with Wiring Diagram. This image shows the rear of the timer switch, including the terminal block for electrical connections and the printed wiring diagram for input (L, N) and output (NO, NC, COM).

4. Setup

4.1 Installation

The THC15A timer switch is designed for DIN rail mounting. Follow these steps for installation:

  1. Disconnect Power: Ensure the main power supply to the installation area is completely switched off before proceeding.
  2. Mounting: Clip the timer switch onto a standard 35mm DIN rail within your electrical panel.
  3. Wiring: Refer to the wiring diagram on the back of the device (Figure 4) and the instructions below for correct connections.
    • Power Input (220V AC): Connect the Live (L) wire to terminal 1 and the Neutral (N) wire to terminal 2.
    • Load Output: Connect the Live wire from the load to terminal 4 (Common). Connect the Live wire to be switched to terminal 3 (Normally Open, NO) for standard operation (power ON when timer is active). If a Normally Closed (NC) connection is required, use terminal 5.
    • Bridging: For typical applications, a bridge wire is required between terminal 1 (Input Live) and terminal 4 (Output Common) if the load is to be powered by the same source as the timer.
  4. Secure Connections: Ensure all wire connections are tight and secure.
  5. Restore Power: Once installation is complete and verified, restore the main power supply.

4.2 Initial Power-Up and Reset

Upon initial power-up or after a prolonged power outage, the display may be blank. The internal battery will charge, and the display should activate within a few minutes. If the display remains blank or shows erratic characters, perform a reset:

  1. Locate the small RESET button on the front panel (usually recessed).
  2. Use a pointed non-metallic object (e.g., a pen tip) to press the RESET button.
  3. The display will clear, and the timer will return to its default settings (00:00, Monday).

5. Operating Instructions

5.1 Setting Current Time and Day

Before programming, set the current time and day:

  1. Press and hold the CLOCK button (often marked with a clock icon).
  2. While holding CLOCK, press D+ to set the current day (MO, TU, WE, TH, FR, SA, SU).
  3. While holding CLOCK, press H+ to set the current hour (0-23).
  4. While holding CLOCK, press M+ to set the current minute (0-59).
  5. Release the CLOCK button. The time is now set.

5.2 Programming ON/OFF Cycles

The timer allows up to 17 ON/OFF programs. Follow these steps:

  1. Press the P button (Program). The display will show '1 ON'.
  2. Press D+ to select the day(s) for this program. You can choose individual days, blocks of days (e.g., MO-FR, SA-SU), or all days (MO-SU).
  3. Press H+ to set the desired ON hour.
  4. Press M+ to set the desired ON minute.
  5. Press P again. The display will show '1 OFF'.
  6. Repeat steps 2-4 to set the OFF time for the first program.
  7. Press P again to move to the next program ('2 ON'). Repeat the process for all desired programs (up to 17 ON/OFF pairs).
  8. To exit programming mode, press the CLOCK button. The timer will return to displaying the current time.

5.3 Manual Override

The MANUAL button allows you to temporarily override the programmed settings:

6. Maintenance

The POPP THC15A Digital Programmable Weekly Timer Switch requires minimal maintenance. Keep the device clean and free from dust. Do not use abrasive cleaners or solvents. Ensure the ventilation slots (if any) are not obstructed. The internal battery is designed for long-term use and is not user-replaceable.

7. Troubleshooting

If you encounter issues with your timer switch, refer to the table below:

ProblemPossible CauseSolution
Display is blank.No power supply; internal battery discharged.Check power connections. Allow time for internal battery to charge (up to 15 minutes). If still blank, perform a reset.
Timer not switching load ON/OFF.Incorrect wiring; program error; manual override active; load exceeds capacity.Verify wiring according to Figure 4. Check programmed ON/OFF times. Ensure timer is in 'AUTO' mode. Confirm load does not exceed 16A/3500W.
Time is inaccurate.Initial setting error; significant power fluctuations.Reset and re-set the current time and day. The device has automatic error correction of +/- 30 seconds weekly.
Cannot enter programming mode.Buttons unresponsive; device malfunction.Perform a reset. If the issue persists, contact customer support.

8. Specifications

BrandPopp
Model NumberTHC15A
ColorWhite
Product Dimensions (L x W x H)6.5 x 3.6 x 8.6 cm (65P x 36l x 86H millimeters)
MaterialPlastic
Item Weight140 Grams
ManufacturerPOPP
Number of SettingsUp to 17 ON/OFF programs
International Article Code (UPC)08435551570641
Screen Size2 Inches
Voltage220-240V AC
Current Rating16A
Frequency50/60Hz

9. Warranty and Support

Specific warranty information for the POPP THC15A Digital Programmable Weekly Timer Switch is not provided in this document. For warranty details, technical support, or service inquiries, please refer to the product packaging or contact the manufacturer directly. Keep your purchase receipt as proof of purchase.