Introduction
This manual provides comprehensive instructions for the safe and effective use of LOCTITE HYSOL 83176 EA 0151 Epoxy Adhesive. This two-part epoxy system is designed for strong, durable bonds across various materials, offering a 50-minute worklife and an ultra-clear finish for general purpose applications, including carpentry, masonry, and tile repair.
Safety Information
Always read the product label and Safety Data Sheet (SDS) before use.
- Wear appropriate personal protective equipment, including chemical-resistant gloves and eye protection (safety glasses or goggles).
- Use in a well-ventilated area to avoid inhaling fumes. If ventilation is insufficient, use respiratory protection.
- Avoid contact with skin and eyes. In case of contact, flush immediately with plenty of water and seek medical attention.
- Keep out of reach of children and pets.
- Do not ingest. If swallowed, do not induce vomiting; seek immediate medical attention.
- Dispose of unused product and waste materials according to local regulations.
Product Components
The LOCTITE HYSOL 83176 EA 0151 Epoxy Adhesive kit typically includes:
- One tube of Epoxy Resin (Part A)
- One tube of Hardener (Part B)
- Total Net Weight: 3.34 oz (94.7 g)

This image displays the LOCTITE HYSOL 83176 EA 0151 Epoxy Adhesive kit. The kit includes a yellow and red box labeled 'LOCTITE EA 0151 ADHESIVE' with 'PART NO. 83176' and 'KIT NET WT. 3.34 OZ'. Next to the box are two yellow tubes, one larger and one smaller, both labeled 'LOCTITE EA 0151 EPOXY ADHESIVE' and 'PART NO. 83176', representing the resin and hardener components.
Specifications
| Product Name | LOCTITE HYSOL 83176 EA 0151 Epoxy Adhesive |
| Model Number | RSH-079340-83176 (Part No. 83176) |
| Kit Size | 3.34 oz (94.7 g) |
| Material | Epoxy Resin |
| Item Form | Liquid |
| Worklife | Approximately 50 minutes |
| Appearance | Ultra Clear |
| Special Features | Strong Bonding, Chemical Resistant |
| Specific Uses | Carpentry, Masonry, Tile Repair |
Setup
- Surface Preparation: Ensure all surfaces to be bonded are clean, dry, and free from oil, grease, dust, and other contaminants. For optimal adhesion, lightly abrade smooth surfaces with sandpaper (e.g., 120-grit) and then wipe clean.
- Temperature: For best results, apply the adhesive at room temperature (20-25°C / 68-77°F). Performance may be affected by extreme temperatures.
- Gather Tools: Prepare a clean, disposable mixing surface (e.g., cardboard, plastic sheet) and a stir stick or spatula for mixing.
Operating Instructions
- Dispense: Squeeze out equal volumes of Part A (Resin) and Part B (Hardener) onto the clean mixing surface. It is crucial to maintain a 1:1 ratio by volume for proper curing.
- Mix: Thoroughly mix the two components with the stir stick for at least 2 minutes, or until a uniform color and consistency are achieved. Scrape the sides and bottom of the mixing surface to ensure all material is incorporated.
- Apply: Immediately after mixing, apply a thin, even layer of the mixed adhesive to one of the prepared surfaces. Work quickly, as the adhesive has a 50-minute worklife.
- Assemble: Bring the parts together and hold them firmly in place. If necessary, use clamps, tape, or weights to maintain contact during the initial curing phase.
- Cure: Allow the adhesive to cure undisturbed. Initial handling strength is typically achieved within a few hours, but full cure and maximum bond strength may take 24 hours or longer, depending on temperature and humidity.
Maintenance
- Cleaning Tools: Clean mixing tools and any spills immediately with appropriate solvents (e.g., acetone or isopropyl alcohol) before the adhesive cures. Once cured, the adhesive is very difficult to remove.
- Storage: Store the unused adhesive tubes in their original packaging in a cool, dry place, away from direct sunlight and extreme temperatures. Ensure caps are tightly sealed to prevent air exposure.
Troubleshooting
- Adhesive Not Curing:
- Issue: Adhesive remains tacky or soft after the recommended cure time.
- Solution: This is most commonly due to an incorrect mix ratio of Part A and Part B, or insufficient mixing. Ensure equal volumes are dispensed and mixed thoroughly for at least 2 minutes. Low temperatures can also slow curing; ensure application is at room temperature.
- Weak Bond:
- Issue: Bond fails or is easily broken.
- Solution: Improper surface preparation (e.g., dirty, oily, or overly smooth surfaces) is a common cause. Ensure surfaces are clean, dry, and properly abraded if necessary. Applying too thin or too thick a layer can also affect bond strength.
Support