FrSky FRS03020101

Download PDF
Contents

FrSky 2.4GHz ACCESS Archer M+ Mini Receiver Instruction Manual

Model: FRS03020101

1. Introduction

This manual provides essential information for the safe and effective operation of your FrSky 2.4GHz ACCESS Archer M+ Mini Receiver. Please read this manual thoroughly before use to ensure proper setup and functionality. The Archer M+ receiver is designed for remote control applications, offering a compact form factor and utilizing the ACCESS protocol for enhanced performance.

2. Key Features

  • ACCESS protocol with Over The Air (OTA) firmware updates.
  • Compact and lightweight design.
  • Full control range with 500 to 600 meters telemetry range.
  • SBUS OUT support.
  • S.Port / F.Port for telemetry functions.
  • Inverted S.Port.
  • Supports 16/24 SBUS channels.
  • Operating Voltage Range: 3.5 - 10V.

3. Product Overview

Top view of the FrSky Archer M+ Mini Receiver, showing the antenna connection and pin headers.

Figure 1: Top view of the FrSky Archer M+ Mini Receiver. This image displays the compact circuit board with the antenna wire connected, highlighting the pin headers for connections and the overall small size of the receiver.

Angled view of the FrSky Archer M+ Mini Receiver, showing the integrated button and antenna.

Figure 2: Angled view of the FrSky Archer M+ Mini Receiver. This perspective shows the receiver's circuit board, including a small button for binding or configuration, and the attached antenna wire extending from the unit.

Close-up view of the FrSky Archer M+ Mini Receiver, focusing on the circuit board and antenna connection.

Figure 3: Close-up view of the FrSky Archer M+ Mini Receiver. This detailed image highlights the components on the circuit board, the antenna connection point, and the compact nature of the receiver.

4. Setup and Binding

The Archer M+ receiver uses the ACCESS protocol. Ensure your FrSky transmitter is updated to the latest ACCESS firmware.

4.1. Wiring Connections

Connect the receiver to your flight controller or power source according to the following pinout:

  • GND: Ground connection.
  • VCC: Power input (3.5V - 10V).
  • SBUS OUT: SBUS signal output to flight controller.
  • S.Port / F.Port: Telemetry data port.

4.2. Binding Procedure

  1. Power on your FrSky transmitter and navigate to the Model Setup menu.
  2. Select the ACCESS protocol and choose the 'Bind' option.
  3. While holding the F/S button on the Archer M+ receiver, connect power to the receiver. The LED on the receiver will indicate binding mode.
  4. On your transmitter, select 'Bind' again. The receiver's LED will change to indicate successful binding.
  5. Power cycle both the receiver and transmitter. Verify control and telemetry functionality.

For Over-The-Air (OTA) firmware updates, refer to your transmitter's manual for specific instructions on initiating the update process.

5. Operating Instructions

Once successfully bound, the Archer M+ receiver will establish a connection with your FrSky ACCESS enabled transmitter upon power-up. The receiver's LED status indicates its operational state:

  • Solid Green: Receiver is bound and receiving a strong signal.
  • Flashing Green: Receiver is bound but signal is weak or intermittent.
  • Solid Red: Receiver is in binding mode or has failed to bind.
  • No LED: No power to the receiver.

The S.Port/F.Port allows for telemetry data transmission back to your transmitter, providing real-time information such as battery voltage, RSSI (Received Signal Strength Indication), and other sensor data if configured. Consult your flight controller and transmitter manuals for telemetry setup and display.

6. Maintenance

  • Keep the receiver clean and free from dust and moisture.
  • Avoid exposing the receiver to extreme temperatures or direct sunlight.
  • Regularly inspect antenna connections for damage. Ensure the antenna is positioned correctly for optimal signal reception.
  • Periodically check for and apply firmware updates via the OTA function to ensure optimal performance and access to new features.

7. Troubleshooting

7.1. Receiver Not Binding

  • Ensure your transmitter is in ACCESS mode and the firmware is up to date.
  • Verify the binding procedure is followed correctly (holding F/S button while powering on).
  • Check power supply to the receiver (3.5V - 10V).
  • Ensure the receiver is within close proximity to the transmitter during the binding process.

7.2. Loss of Signal / Intermittent Connection

  • Check antenna placement and ensure it is not obstructed by carbon fiber or metal components.
  • Inspect the antenna for any physical damage.
  • Ensure the transmitter's RF module is functioning correctly.
  • Avoid operating in areas with high RF interference.

7.3. No Telemetry Data

  • Verify the S.Port/F.Port connection to your flight controller or telemetry hub.
  • Ensure telemetry is enabled and configured correctly in your flight controller firmware and transmitter settings.
  • Check for any loose or incorrect wiring.

8. Specifications

SpecificationValue
Dimensions17 x 11.7 x 4 mm (L*W*H)
Weight1g
Number of Channels16/24 SBUS channels
Operating Voltage Range3.5 - 10V
Operating Current16mA@5V (typical)
Operating Range>1.2km (Full range)
Telemetry Range500 - 600 meters
CompatibilityAll FrSky ACCESS transmitters
Connectivity TechnologyS.Port / F.Port

Note: Specifications are subject to change without prior notice. Operating range may vary based on local conditions and environmental factors.

9. Warranty and Support

FrSky products are designed and manufactured to high-quality standards. For warranty information, please refer to the official FrSky website or contact your local distributor. Keep your proof of purchase for any warranty claims.

For technical support, firmware updates, and additional resources, please visit the official FrSky website: www.frsky-rc.com

© 2025 FrSky. All rights reserved.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.