Danfoss KP1 060-1101
Danfoss KP1 060-1101 Pressure Switch Instruction Manual
Model: KP1 060-1101
1. Introduction
This manual provides essential information for the safe and efficient installation, operation, and maintenance of the Danfoss KP1 060-1101 Pressure Switch. The KP1 pressure switch is designed for regulating, monitoring, and alarm systems in industrial applications. It features a single-pole double-throw (SPDT) contact system and is suitable for various pressure control tasks.

Figure 1: Danfoss KP1 060-1101 Pressure Switch as supplied in its packaging.
2. Safety Information
Always adhere to local regulations and safety standards when installing, operating, or servicing the pressure switch. Failure to do so may result in personal injury or equipment damage.
- Installation and service must be performed by qualified personnel only.
- Disconnect power supply before performing any electrical connections or maintenance.
- Ensure the system pressure is relieved before connecting or disconnecting the pressure switch.
- Do not exceed the specified maximum operating pressure and electrical ratings.
- Protect the switch from moisture, dust, and extreme temperatures unless specifically designed for such conditions.
3. Setup and Installation
3.1. Mounting
The KP1 pressure switch can be mounted in any position. Ensure the mounting location is free from excessive vibration and provides adequate space for wiring and adjustments.

Figure 2: Isometric view of the KP1 pressure switch, highlighting the pressure connection point.
3.2. Pressure Connection
Connect the pressure switch to the system using appropriate fittings. Ensure a leak-free connection. The switch is designed for direct connection to the pressure line.

Figure 3: Danfoss KP1 pressure switch, showing the threaded pressure connection at the bottom.
3.3. Electrical Connection
The KP1 060-1101 features screw terminals for electrical connections. Refer to the wiring diagram inside the switch cover for correct connections. Ensure all connections are secure and comply with electrical codes.
- Disconnect power before wiring.
- Connect the power supply and load to the appropriate terminals.
- The switch has a Normally Closed (NC) contact type.
3.4. Pressure Setting Adjustment
The KP1 pressure switch allows adjustment of both the cut-in/cut-out pressure (Range) and the differential pressure (Diff). These adjustments are typically made using screws located under the cover.

Figure 4: Close-up view of the Range and Differential adjustment scales on the Danfoss KP1 pressure switch.
- Range Adjustment: Use the screw associated with "RANGE" to set the desired cut-out pressure.
- Differential Adjustment: Use the screw associated with "DIFF" to set the difference between the cut-in and cut-out pressures.
- Ensure the system is depressurized before making adjustments.
4. Operating Instructions
Once installed and adjusted, the Danfoss KP1 060-1101 operates automatically based on the set pressure range. It functions as an automatic pressure controller.
- The switch will activate or deactivate connected equipment when the system pressure reaches the set cut-in or cut-out points.
- Some models may feature a manual reset button (indicated as "Reset Auto" in some diagrams). If present, this button allows for manual resetting of the switch after an alarm condition or power interruption.
5. Maintenance
The Danfoss KP1 pressure switch is designed for minimal maintenance. Regular inspection is recommended to ensure optimal performance and longevity.
- Visual Inspection: Periodically check the switch for any signs of physical damage, corrosion, or loose connections.
- Cleaning: Keep the exterior of the switch clean and free from dust and debris. Use a dry, soft cloth. Do not use abrasive cleaners or solvents.
- Functionality Check: If possible and safe to do so, periodically verify the switch's operation by observing its response to pressure changes within the system.
6. Troubleshooting
Before attempting any troubleshooting, ensure the power supply is disconnected and system pressure is relieved.
| Problem | Possible Cause | Solution |
|---|---|---|
| Switch does not activate/deactivate | Incorrect pressure settings No power supply Faulty wiring Clogged pressure port | Verify and adjust Range and Differential settings Check power connections and circuit breaker Inspect wiring for loose or incorrect connections Clean pressure port |
| Erratic operation | Excessive vibration Pressure fluctuations Internal fault | Relocate switch or use vibration dampeners Stabilize system pressure Contact Danfoss support or replace switch |
| Leakage at pressure connection | Improperly tightened fitting Damaged seal/thread | Retighten connection (ensure system is depressurized) Replace seal or fitting |
If the problem persists after attempting these solutions, contact a qualified service technician or Danfoss customer support.
7. Specifications
| Model | KP1 060-1101 |
| Brand | Danfoss |
| Operation Mode | Automatic |
| Current Rating | 4 Amps |
| Contact Type | Normally Closed |
| Connector Type | Screw Terminals |
| Circuit Type | 2-way |
| Actuator Type | Push Button |
| Contact Material | Copper |
| Control Method | Touch |
8. Warranty and Support
Danfoss products are manufactured to high-quality standards and are covered by a standard manufacturer's warranty. For specific warranty terms and conditions, please refer to the documentation provided with your purchase or visit the official Danfoss website.
For technical support, spare parts, or service inquiries, please contact your local Danfoss distributor or visit www.danfoss.com.