1. Introduction
This manual provides detailed instructions for the proper setup, operation, and maintenance of your PROEL Eikon WM700DMA Dual-Channel PLL UHF Wireless Handheld Microphone System. Please read this manual thoroughly before using the system to ensure optimal performance and to prevent damage.
The Eikon WM700DMA is a professional dual-channel wireless microphone system designed for various applications, including karaoke, singing, and public address systems. It operates within the 518-550 MHz frequency range, offering reliable wireless connectivity.
2. Important Safety Information
- Do not expose the unit to rain or moisture to prevent fire or electric shock.
- Do not open the casing. Refer all servicing to qualified personnel.
- Ensure proper ventilation around the receiver unit.
- Use only the power adapter supplied with the system.
- Keep the system away from heat sources and direct sunlight.
- Dispose of batteries responsibly according to local regulations.
3. Package Contents
Verify that all items listed below are included in your package:
- WM700DMA Dual-Channel Wireless Receiver
- 2 x Handheld Wireless Microphones
- Power Adapter
- Audio Cable (e.g., 1/4" to 1/4" or XLR to 1/4") - (Note: Specific cable type not detailed in product info, common for such systems)
- Carrying Case
- User Manual (this document)
4. Product Overview
4.1. WM700DMA Receiver Front Panel

Image 4.1: Front view of the WM700DMA receiver. It features two volume control knobs (VOL A, VOL B), SET buttons, up/down navigation buttons, IR sync windows, a central LCD display, and a POWER button.
- VOL A / VOL B: Adjusts the output volume for Channel A and Channel B respectively.
- SET Button: Used to enter menu settings or confirm selections.
- Up/Down Buttons: Navigates through menu options or adjusts parameters.
- IR Window: Infrared sensor for syncing frequencies with the handheld microphones.
- LCD Display: Shows channel frequency, signal strength, and other operational information.
- POWER Button: Turns the receiver ON or OFF.
4.2. WM700DMA Receiver Rear Panel

Image 4.2: Rear view of the WM700DMA receiver. It includes a power input, two balanced XLR outputs (Balanced B, Balanced A), and an auxiliary 1/4" output (AUX).
- POWER INPUT (USB): Connects the supplied power adapter.
- BALANCED B / BALANCED A (XLR): Balanced audio outputs for Channel B and Channel A. Connect these to a mixer or PA system.
- AUX (1/4" Jack): Unbalanced auxiliary audio output, combining both channels.
4.3. Handheld Wireless Microphone

Image 4.3: Eikon handheld wireless microphone. It features a display, power/mute button, and an IR sensor for synchronization.
- Microphone Grille: Protects the cardioid dynamic capsule.
- LCD Display: Shows battery status and current channel/frequency.
- Power/Mute Button: Turns the microphone ON/OFF and mutes/unmutes the audio.
- IR Sensor: Receives frequency synchronization signals from the receiver.
- Battery Compartment: Located at the bottom, holds the required batteries (typically AA, not specified in product data, but common).
5. Setup Instructions
- Position the Receiver: Place the WM700DMA receiver in a central location, away from large metal objects or other wireless devices that might cause interference.
Ensure the antennas are extended and positioned for optimal reception.
Image 5.1: WM700DMA receiver with antennas extended for improved signal reception.
- Connect Power: Connect the supplied power adapter to the POWER INPUT (USB) on the rear of the receiver and plug it into a suitable power outlet.
- Connect Audio Output:
- For individual channel output, connect XLR cables from BALANCED A and BALANCED B to your mixer or PA system's input channels.
- For a mixed output of both channels, connect a 1/4" cable from the AUX output to your mixer or PA system's input.
- Install Microphone Batteries: Open the battery compartment of each handheld microphone and insert the required batteries (e.g., 2x AA batteries per microphone, check markings on the device). Ensure correct polarity.
- Power On: Turn on the receiver by pressing the POWER button. Turn on each handheld microphone by pressing and holding its Power/Mute button.
- Frequency Synchronization (IR Sync):
- On the receiver, select the desired channel (A or B) and frequency using the SET and Up/Down buttons.
- Hold the microphone's IR sensor close to the receiver's IR window.
- Press the SET button on the receiver. The display on both the receiver and microphone should indicate successful synchronization. Repeat for the second microphone on the other channel.
- Initial Sound Check: Speak into each microphone and adjust the VOL A and VOL B knobs on the receiver, as well as the input gain on your mixer/PA system, to achieve a clear audio level without distortion.
6. Operating Instructions
6.1. Receiver Operation
- Volume Control: Use the VOL A and VOL B knobs to adjust the individual output levels of each microphone channel.
- Channel/Frequency Selection: Press the SET button to enter the frequency selection mode. Use the Up/Down buttons to change the frequency. Press SET again to confirm.
- IR Sync: If a microphone loses connection or needs to be paired with a different channel, follow the synchronization steps outlined in Section 5.
6.2. Microphone Operation
- Power ON/OFF: Press and hold the Power/Mute button to turn the microphone ON or OFF.
- Mute Function: Briefly press the Power/Mute button to mute or unmute the microphone. The display will indicate the mute status.
- Battery Indicator: The microphone's LCD display shows the current battery level. Replace batteries when the indicator is low to avoid interruptions.
- Optimal Usage: Hold the microphone approximately 2-6 inches (5-15 cm) from your mouth for best sound quality. Avoid covering the grille with your hand.
7. Maintenance
- Cleaning: Use a soft, dry cloth to clean the receiver and microphones. Do not use liquid cleaners or solvents.
- Storage: When not in use for extended periods, remove batteries from the microphones and store the system in its carrying case in a cool, dry place.
- Battery Replacement: Replace microphone batteries promptly when the low battery indicator appears. Use high-quality alkaline batteries for best performance.
- Antenna Care: Handle receiver antennas carefully to avoid bending or breaking.
8. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| No sound from microphone. |
|
|
| Interference or static. |
|
|
| Microphone not syncing. |
|
|
9. Specifications
| Feature | Detail |
|---|---|
| Brand | PROEL |
| Model Number | EIKONWM700DM |
| Frequency Range | 518 – 550 MHz |
| Connectivity Technology | UHF, USB |
| Connector Type | USB (for power), XLR, 1/4" Jack |
| Number of Channels | 2 |
| Microphone Type | Handheld, Cardioid Dynamic Capsule |
| Polar Pattern | Unidirectional |
| Signal-to-Noise Ratio | 80 dB (System), 105 dB (Microphone Audio Sensitivity) |
| Frequency Response | 15 KHz (Upper limit, typical for audio) |
| Recommended Uses | Karaoke, Singing |
| Compatible Devices | PA System, Personal Computer (via audio output) |
| Item Weight | 2000 Grams (System) |
| Item Dimensions | 14.5 x 10.2 x 7.9 inches (Receiver) |
| Included Components | Carrying Case |
10. Warranty and Support
PROEL products are designed and manufactured to the highest quality standards. For information regarding warranty coverage, technical support, or service, please refer to the warranty card included with your product or visit the official PROEL website.
Please retain your proof of purchase for any warranty claims.