1. Product Overview

The Total TWP47506 750W Automatic Jet Water Pump is designed for efficient clean water collection and distribution. It is suitable for drawing water from wells, boreholes, open tanks, and other water supply sources. Primary applications include watering vegetable gardens, personal plots, and ensuring water circulation in fountains and various water features. Its design prioritizes ease of maintenance and portability, featuring an external tank location. The pump incorporates a brushless induction motor for long-lasting, maintenance-free operation. The robust cast iron pump casing can be rotated 90 degrees for flexible installation. This pump is capable of integration into automated water supply systems.

Total TWP47506 750W Automatic Jet Water Pump

Figure 1: Total TWP47506 750W Automatic Jet Water Pump. This image shows the complete pump unit with its motor and casing.

2. Safety Instructions

Read all safety warnings and instructions carefully before operating this product. Failure to follow these instructions may result in electric shock, fire, and/or serious injury.

General Safety

  • Always wear appropriate personal protective equipment (PPE) such as safety glasses and gloves.
  • Ensure the pump is placed on a stable, level surface to prevent tipping.
  • Keep children and unauthorized persons away from the operating area.
  • Do not operate the pump in explosive atmospheres, such as in the presence of flammable liquids, gases, or dust.
  • Never use the pump to transfer flammable, corrosive, or explosive liquids.
  • Disconnect the power supply before performing any maintenance, cleaning, or when the pump is not in use.

Electrical Safety

  • Ensure the power supply voltage matches the specifications on the pump's rating label (220-240V, 50Hz).
  • Use a properly grounded outlet. Do not modify the plug.
  • Do not expose the pump or electrical connections to rain or wet conditions.
  • Avoid using extension cords unless absolutely necessary. If an extension cord is used, ensure it is rated for outdoor use and has the correct gauge for the pump's power requirements.
  • Never carry the pump by its power cord.
  • Regularly inspect the power cord for damage. If damaged, have it replaced by a qualified electrician.

3. Package Contents

Verify that all items listed below are present and undamaged upon unpacking:

  • 1 x Total TWP47506 750W Automatic Jet Water Pump
  • 1 x Pressure Switch
  • 1 x Stainless Steel Hose
  • 1 x Pressure Gauge
  • 1 x Three-way Brass Fitting
  • User Manual (this document)

4. Technical Specifications

Specification Value
Model Number TWP47506
Type Self-priming Automatic Jet Pump
Rated Power 750W (1.0 HP)
Voltage 220-240V
Frequency 50Hz
Max Head 45 meters
Max Flow 60 liters/minute
Max Suction 9 meters
Pipe Diameter 1 x 1 inch
Motor Type Copper Wire Induction Motor (Brushless)
Impeller Material Stainless Steel
Pump Casing Material Cast Iron
Cable Length 0.3 meters
Tank Capacity (Cylindrical) 24 liters
Product Dimensions (L x W x H) 30 x 19 x 22 cm
Item Weight 1.5 kg
Color Silver

5. Setup and Installation

5.1 Placement

  • Position the pump on a firm, level, and dry surface.
  • Ensure adequate ventilation around the pump to prevent overheating.
  • Protect the pump from direct exposure to weather elements (rain, direct sunlight, frost).
  • Keep the pump as close as possible to the water source to minimize suction lift and maximize efficiency.

5.2 Connecting Pipes

The pump is equipped with standard inch fittings for both suction and discharge pipes.

  • Suction Pipe: Connect a rigid, airtight suction pipe (1 inch diameter) to the pump's inlet. Ensure all connections are sealed to prevent air leaks, which can affect priming and pump performance. A foot valve with a strainer should be installed at the end of the suction pipe submerged in the water source to prevent debris from entering the pump and to maintain prime.
  • Discharge Pipe: Connect a discharge pipe (1 inch diameter) to the pump's outlet. Use the provided three-way brass fitting, pressure switch, and pressure gauge as part of your water supply system. Ensure all connections are secure.

5.3 Priming the Pump

This is a self-priming pump, but initial priming is crucial for proper operation. Before first use or after the pump has run dry:

  1. Ensure the suction pipe is fully submerged in the water source.
  2. Locate the priming plug on the top of the pump casing.
  3. Unscrew the priming plug and slowly fill the pump casing with clean water until it overflows.
  4. Replace and securely tighten the priming plug.
  5. Open any valves on the discharge side to allow air to escape during startup.

5.4 Electrical Connection

  • Connect the pump's power cord to a grounded electrical outlet (220-240V, 50Hz).
  • Ensure the electrical circuit is protected by a Residual Current Device (RCD) for added safety.

6. Operation

6.1 Starting the Pump

  1. Ensure the pump has been properly primed (Section 5.3).
  2. Verify all pipe connections are secure and leak-free.
  3. Plug the pump into the power outlet. The pump will start automatically if connected to an automated system with a pressure switch.
  4. Observe the pressure gauge. The pressure should rise as the pump builds pressure.
  5. If the pump does not draw water within a few minutes, switch it off, re-prime, and check for air leaks in the suction line.

6.2 Automatic Operation

When integrated into a water supply system with the included pressure switch, the pump will automatically start when water pressure drops (e.g., when a tap is opened) and stop when the desired pressure is reached (e.g., when the tap is closed). The 24-liter cylindrical tank helps maintain consistent pressure and reduces pump cycling.

6.3 Stopping the Pump

For temporary shutdown, close all water outlets. The pump will stop automatically if operating in an automated system. For complete shutdown or extended periods of non-use, unplug the pump from the power supply.

7. Maintenance

Regular maintenance ensures optimal performance and extends the lifespan of your pump. Always disconnect the power supply before performing any maintenance.

7.1 Regular Checks

  • Inspect the power cord and plug for any signs of damage.
  • Check all pipe connections for leaks. Tighten if necessary.
  • Ensure the foot valve strainer is clear of debris. Clean if clogged.
  • Listen for unusual noises during operation, which may indicate a problem.

7.2 Cleaning

Wipe down the exterior of the pump with a damp cloth. Do not use harsh chemicals or abrasive cleaners. Ensure the motor's ventilation openings are free from dust and debris.

7.3 Winterization (for cold climates)

If the pump is exposed to freezing temperatures, it must be drained to prevent damage:

  1. Disconnect the power supply.
  2. Drain all water from the pump casing by unscrewing the drain plug (if present) or by tilting the pump.
  3. Disconnect the suction and discharge pipes and drain them completely.
  4. Store the pump in a dry, frost-free location.

8. Troubleshooting

Before contacting customer support, refer to the following table for common issues and solutions.

Problem Possible Cause Solution
Pump does not start No power supply
Faulty power cord/plug
Motor overload protection tripped
Check power connection and outlet
Inspect and replace if damaged
Allow motor to cool, then restart. Check for blockages.
Pump runs but no water is delivered Pump not primed
Air leak in suction line
Suction lift too high
Foot valve clogged or stuck
Water source empty
Re-prime the pump (Section 5.3)
Check all suction connections for leaks and tighten
Relocate pump closer to water source
Clean or replace foot valve
Ensure adequate water in source
Low flow or pressure Partial blockage in pipes/impeller
Air leak in suction line
Worn impeller
Incorrect pressure switch setting
Inspect and clear blockages
Check and seal suction connections
Contact qualified service personnel
Adjust pressure switch according to manufacturer guidelines (if adjustable)
Pump cycles on and off frequently Leak in discharge system
Pressure tank pre-charge incorrect
Faulty pressure switch
Check for leaks in pipes, fittings, or fixtures
Check and adjust pressure tank air pre-charge
Inspect and replace pressure switch if necessary

9. Warranty and Support

This Total TWP47506 750W Automatic Jet Water Pump comes with a standard manufacturer's warranty. Please refer to the warranty card included with your purchase for specific terms and conditions, including warranty period and coverage details.

For technical assistance, spare parts, or warranty claims, please contact Total customer support through your retailer or visit the official Total website for contact information in your region. When contacting support, please have your model number (TWP47506) and purchase date available.

© 2023 Total Inc. All rights reserved. Information in this manual is subject to change without notice.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.