Locinox LMKQ40 V2

LOCINOX Vinci Surface Mounted Mechanical Code Gate Lock - LMKQ40 V2 User Manual

Model: LMKQ40 V2

1. Product Overview

The LOCINOX Vinci Surface Mounted Mechanical Code Gate Lock (LMKQ40 V2) is a robust and reliable locking solution designed for gates. This fully mechanical lock requires no batteries or electricity, offering secure access control through a code panel on both sides. Constructed with a stainless steel mechanism and an aluminum housing, it features a polyamide rain and dust cover for enhanced durability. The lock box is KTL / E-coated, providing resistance against 1000 hours of salt spray, ensuring longevity in various environmental conditions. Its design allows for reversibility, accommodating both left-handed and right-handed gate applications.

Key Features:

2. Safety Information

Please read and understand all instructions before installing and operating the LOCINOX Vinci gate lock. Failure to follow these instructions may result in property damage or injury.

3. Package Contents

Verify that all components are present before beginning installation:

4. Setup and Installation

This section provides general guidance for installing the LOCINOX Vinci gate lock. Refer to the detailed installation template and specific instructions provided with your product for precise measurements and steps. Professional installation is recommended.

4.1. Pre-Installation Checks:

4.2. Reversing the Latch Bolt (if necessary):

The lock is designed to be reversible. If the latch bolt is not oriented correctly for your gate's opening direction, follow the manufacturer's instructions to reverse it. This typically involves removing a retaining screw, rotating the bolt, and re-securing it.

4.3. Mounting the Lock:

  1. Position the lock body on the gate frame at the desired height.
  2. Mark the drilling points for the mounting screws and the spindle hole.
  3. Drill pilot holes as indicated by the template.
  4. Secure the lock body to the gate frame using the provided mounting hardware.
  5. Install the strike plate on the gate post, ensuring proper alignment with the latch bolt.
  6. Test the gate's operation to ensure smooth locking and unlocking.
LOCINOX Vinci Surface Mounted Mechanical Code Gate Lock installed on a gate post, showing the code panel, handle, and key cylinder.

Image 1: The LOCINOX Vinci LMKQ40 V2 lock mounted on a gate post, illustrating its surface-mounted design, mechanical code panel, and handle with key override.

5. Operating Instructions

5.1. Setting/Changing the Code:

The LOCINOX Vinci lock features a fully mechanical code panel. To set or change the access code, refer to the specific instructions provided by Locinox for your model. This process typically involves accessing the internal mechanism (often by removing the cover) and repositioning the code pins or tumblers according to your desired code sequence. Ensure the cover is securely re-attached after changing the code.

5.2. Unlocking with the Code:

  1. Enter your pre-set access code on the keypad.
  2. Once the correct code is entered, the handle will engage.
  3. Turn the handle to retract the latch bolt and open the gate.
  4. Release the handle to allow the latch bolt to extend and secure the gate when closed.

5.3. Key Override Function:

The lock includes a key cylinder for manual override. Insert the provided key into the cylinder and turn it to unlock the mechanism, allowing the handle to operate without entering the code. This is useful for temporary access or in situations where the code is forgotten.

6. Maintenance

Regular maintenance ensures the longevity and reliable operation of your LOCINOX Vinci gate lock.

7. Troubleshooting

If you encounter issues with your LOCINOX Vinci gate lock, refer to the following common troubleshooting steps:

ProblemPossible CauseSolution
Code not working / Handle not engagingIncorrect code entered; Code pins not set correctly; Internal mechanism obstruction.Re-enter the code carefully. Verify the code setting (refer to Section 5.1). Check for debris or foreign objects obstructing the buttons or mechanism.
Latch bolt not retracting smoothlyLack of lubrication; Misalignment with strike plate; Debris in mechanism.Apply silicone lubricant to the latch bolt. Check strike plate alignment and adjust if necessary. Clean any debris from the bolt path.
Key override not workingIncorrect key; Key cylinder obstructed; Internal damage.Ensure you are using the correct key. Check for debris in the keyway. If the issue persists, contact support.
Gate not securing properlyStrike plate misalignment; Latch bolt not extending fully; Gate sag.Adjust the strike plate position. Inspect the latch bolt for full extension. Address any gate alignment issues.

If these steps do not resolve the issue, please contact Locinox customer support for further assistance.

8. Specifications

FeatureDetail
BrandLocinox
Model NumberLMKQ40 V2 (Item model number: 5056240112565)
Lock TypeMechanical Combination Lock with Key Override
Mounting TypeSurface Mounted
MaterialStainless Steel mechanism, Aluminum housing
Cover MaterialPolyamide (rain and dust cover)
Corrosion ResistanceISO 9227 KTL / E-coated lock box (1000 hours salt spray test)
HandingReversible (Left or Right)
ColorBlack
Item Weight5 pounds
Included ComponentsMounting Hardware, Keys

9. Warranty and Support

For specific warranty information regarding your LOCINOX Vinci Surface Mounted Mechanical Code Gate Lock, please refer to the documentation included with your purchase or visit the official Locinox website. Warranty terms and conditions may vary.

If you require technical assistance, have questions about installation, operation, or need to report a defect, please contact Locinox customer support directly. Contact details can typically be found on the manufacturer's website or in your product packaging.

Manufacturer: Locinox

Website: www.locinox.com (or relevant regional site)

10. Product Videos

No official product videos are available for embedding at this time. Please check the manufacturer's website for any instructional videos or demonstrations.

Related Documents - LMKQ40 V2

Preview LAKQ U2 Industrial Lock - Specifications, Performance, and Material Details | Locinox
Comprehensive technical specifications, performance metrics, installation guidelines, and material composition for the Locinox LAKQ U2 Industrial Lock, designed for durability and professional use.
Preview Locinox VINCI LMKQV2 Installation Guide
Detailed installation instructions for the Locinox VINCI LMKQV2 lock, covering all steps from preparation to final setup.
Preview Locinox Vera Electronic Code Lock: Installation, Programming, and User Manual
A comprehensive guide to the Locinox Vera electronic code lock, covering installation, programming of PIN codes, access modes, maintenance, and troubleshooting. Features detailed instructions for setup and operation.
Preview Locinox Fortima-SD-K Pool Safety Gate Lock Installation Guide
Detailed installation instructions for the Locinox Fortima-SD-K pool safety gate lock. Learn how to properly install, adjust, and change the cylinder for secure gate operation. Includes safety guidelines and contact information.
Preview Locinox FREE VINCI LFKQX1 Installation Guide - Step-by-Step Instructions
Detailed installation guide for the Locinox FREE VINCI LFKQX1 lock mechanism. Learn how to install and set up your Locinox door hardware with clear instructions and diagrams.
Preview LOCINOX MAGNUS Gate Motor: Installation, Safety, and Technical Guide
This guide provides essential information for the installation, safe operation, and technical specifications of the LOCINOX MAGNUS gate motor. It covers safety notices, connection diagrams, and product details for automated swing gates.