Safety Information

WARNING: Failure to follow these safety instructions may result in serious injury or property damage.

  • Always wear appropriate personal protective equipment (PPE) such as gloves and eye protection when handling fluids.
  • Ensure the pump is securely installed in the drum before operation.
  • Do not use this pump with corrosive chemicals, highly flammable liquids (like gasoline), or liquids incompatible with the pump's materials (Steel, Aluminum, Zinc, Brass, PTFE). Refer to the "Compatible Liquids" section.
  • Keep children and unauthorized personnel away from the pump during operation.
  • Avoid spills. Clean up any spills immediately and dispose of waste properly.
  • Do not modify the pump in any way. Use only genuine TERA PUMP replacement parts.

Product Overview and Components

The TERA PUMP TRLTSTEEL is a manual, vertical lift-action pump designed for transferring various liquids from 15, 30, and 55-gallon drums. It features a telescopic tube and an adjustable bung adapter for versatile use.

Diagram of TERA PUMP TRLTSTEEL pump with dimensions

Image: A detailed diagram illustrating the dimensions and key components of the TERA PUMP TRLTSTEEL pump, including overall length, suction pipe diameter, pump handle width, discharge spout length, discharge spout opening diameter, and bunghole adapter diameter.

Key Features:

  • Lift-Action Mechanism: Manual operation, no electricity required.
  • High Flow Rate: Transfers up to 26 oz (750 ml) per stroke.
  • Adjustable Bung Adapter: Fits 15, 30, and 55-gallon drum barrels.
  • Durable Construction: Made from Steel, Aluminum, Zinc, Brass, and PTFE with wear-resistant brass piston rings.

Specifications

FeatureDetail
Model NumberTRLTSTEEL (A-TP-TRLTSTEEL-001)
Flow RateUp to 26 oz (750 ml) per stroke
Compatible Drum Sizes15, 30, and 55 Gallon Drum Barrels
Bung Adapter2-inch NPS (Adjustable)
MaterialsSteel, Aluminum, Zinc, Brass, PTFE
Piston RingsWear Resistant Brass
Power SourceManual Power (Lift-Action)
Item Weight5.19 pounds
Package Dimensions46.2 x 3.7 x 2.9 inches

Compatible Liquids

This pump is designed for transferring a variety of liquids, including:

  • Antifreeze
  • Diesel
  • High viscosity petroleum-based media
  • Hydraulic Fluid
  • Kerosene
  • Lacquer thinners
  • Light Oils (up to 40 weight)
  • Most types of paint thinners
  • Some non-corrosive chemicals

Do NOT use with water, highly corrosive acids, or highly flammable liquids like gasoline.

Setup Instructions

  1. Unpack Components: Carefully remove all pump components from the packaging. Inspect for any damage.
  2. Assemble Telescopic Tube: If not already assembled, connect the telescopic tube sections. Ensure they are securely fastened.
  3. Insert Intake Tube into Drum: Insert the pump's intake tube into the drum opening.
  4. Adjust and Secure Bung Adapter: Slide the 2-inch NPS bung adapter down the pump shaft until it rests firmly on the drum opening. Secure the adapter to the drum by tightening its mechanism. This ensures stability and proper sealing.
Three step diagram showing pump setup: insert intake tube, tighten intake tube, press piston to pump

Image: A visual guide demonstrating the three main steps for setting up the pump: inserting the intake tube, tightening the bung adapter, and initiating the pumping action.

Close-up of 2-inch NPS bung adapter securing pump to drum

Image: A close-up view of the 2-inch NPS bung adapter, showing how it secures the pump to the drum opening and allows for height adjustment to fit various drum sizes.

Operating Instructions

  1. Position Receiving Container: Place the receiving container below the discharge spout. Ensure it is stable and can hold the volume of liquid to be transferred.
  2. Initiate Pumping: Begin pumping the lever with a steady, vertical lift-action. Continue pumping until fluid starts flowing from the discharge spout.
  3. Maintain Flow: Once fluid flow is established, continue the lift-action pumping motion to maintain the transfer. The pump is designed for a continuous flow of up to 26 oz per stroke.
  4. Stop Pumping: To stop the fluid transfer, cease the pumping action.
  5. Remove Pump: Once transfer is complete, carefully remove the pump from the drum. Allow any residual fluid to drain before storing.
Person demonstrating manual lift action pumping

Image: A person demonstrating the manual lift-action pumping process, showing the upward and downward motion required to initiate and maintain fluid transfer.

Person using pump to transfer liquid from drum to container

Image: A user operating the TERA PUMP TRLTSTEEL to transfer liquid from a large drum into a smaller container, highlighting the pump's efficiency of up to 26 oz per stroke.

Maintenance

  • Cleaning: After each use, especially when transferring different types of liquids, flush the pump with a compatible cleaning agent or the next intended fluid to prevent contamination and buildup.
  • Inspection: Regularly inspect the pump for any signs of wear, damage, or leaks. Pay close attention to seals and connections.
  • Lubrication: Periodically lubricate moving parts, such as the piston, with a lubricant compatible with the fluids being pumped.
  • Storage: Store the pump in a clean, dry place away from direct sunlight and extreme temperatures.

Troubleshooting

ProblemPossible CauseSolution
No fluid transfer or slow flow
  • Pump not primed
  • Air leak in connections
  • Intake tube blocked
  • Liquid too viscous
  • Pump lever vigorously to prime
  • Check all connections for tightness
  • Clear any obstructions from the intake
  • Ensure liquid is within compatible viscosity range
Leaking from connections
  • Loose connections
  • Damaged seals or O-rings
  • Tighten all connections
  • Inspect and replace damaged seals/O-rings
Pump handle stiff or difficult to operate
  • Lack of lubrication
  • Internal debris
  • Lubricate piston and moving parts
  • Disassemble and clean internal components

Warranty Information

The TERA PUMP TRLTSTEEL pump is backed by a 1-year manufacturer warranty covering defects in materials and workmanship. Please retain your proof of purchase for warranty claims. For detailed warranty terms and conditions, please refer to the official TERA PUMP website or contact customer support.

Customer Support

For technical assistance, parts, or warranty inquiries, please contact TERA PUMP customer support:

© 2023 TERA PUMP. All rights reserved.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.

Rate this product if you’ve used it

Was this page helpful?