1. Introduction
The Nilox UPS Office Premium Line Interactive 850VA/595W is an uninterruptible power supply designed to protect your computer and peripherals from power outages and electrical disturbances. Featuring Line Interactive technology, it ensures stable power delivery and safeguards against short circuits and overloads. This manual provides essential information for the safe and efficient use of your UPS.
2. Important Safety Instructions
Please read and follow these safety instructions carefully to prevent injury or damage to the unit.
- Do not open the UPS casing. There are no user-serviceable parts inside. Refer servicing to qualified service personnel.
- Do not expose the UPS to water, rain, snow, or excessive humidity.
- Ensure the UPS is placed in a well-ventilated area, away from direct sunlight or heat sources.
- Connect the UPS only to a grounded electrical outlet.
- Do not connect non-computer related equipment (e.g., medical equipment, life support systems) to the UPS.
- Ensure the total load connected to the UPS does not exceed its rated capacity (850VA/595W).
- In case of fire, use a dry chemical fire extinguisher. Water may cause electrical shock.
3. Package Contents
Verify that all items are present in the package:
- Nilox UPS Office Premium Line Interactive 850VA/595W Unit
- Power Cable
- User Manual
4. Product Overview
Familiarize yourself with the components of your Nilox UPS.


4.1. Key Components
- Power Button: Used to turn the UPS on or off.
- Indicator Lights: Provide status information (e.g., AC mode, battery mode, fault, overload).
- Battery Backup Outlets (Schuko): Provide power from the battery during outages and surge protection. Connect critical devices here.
- Surge Protected Outlets (Schuko): Provide surge protection only. Connect non-critical devices here.
- Input Power Cord: Connects the UPS to the wall outlet.
5. Setup
Follow these steps to set up your Nilox UPS:
- Unpacking: Carefully remove the UPS from its packaging. Inspect for any shipping damage.
- Placement: Place the UPS on a flat, stable surface in a clean, dry, and well-ventilated area. Avoid direct sunlight, heat sources, and excessive dust.
- Initial Charging: Before initial use, connect the UPS to a standard wall outlet and allow it to charge for at least 8 hours. This ensures the battery is fully charged and ready to provide optimal backup time.
- Connecting Devices:
- Connect your critical equipment (e.g., computer, monitor, modem) to the Battery Backup outlets. These outlets provide both battery power during an outage and surge protection.
- Connect non-critical equipment (e.g., printer, scanner) to the Surge Protected outlets. These outlets only provide surge protection.
- Power On: Press the power button on the front of the UPS to turn it on. The indicator lights will illuminate, confirming the unit is operational.
5.1. Setup Demonstration Videos
6. Operating Instructions
6.1. Powering On/Off
- To Power On: Press and hold the power button for approximately 2 seconds until the UPS beeps and the indicator lights illuminate.
- To Power Off: Press and hold the power button for approximately 2 seconds until the UPS beeps and the indicator lights turn off.
6.2. Understanding Indicator Lights
The UPS features indicator lights to communicate its status:
- Green Light (Solid): UPS is operating in AC mode, providing power to connected devices and charging the battery.
- Yellow Light (Flashing): UPS is operating in battery mode, providing backup power during a power outage.
- Red Light (Solid): Indicates a fault or overload condition. Refer to the Troubleshooting section.
- Battery Icon: Indicates battery charge level or status.
6.3. Battery Mode Operation
During a power outage, the UPS will automatically switch to battery mode. An audible alarm may sound to indicate this transition. The duration of backup power depends on the load connected and the battery's charge level. It is recommended to save your work and properly shut down your devices during a prolonged outage.
7. Maintenance
7.1. Battery Replacement
The UPS contains a 5Ah battery that is easily replaceable. Over time, batteries lose their capacity. If you notice a significant reduction in backup time, the battery may need replacement. Refer to the manufacturer's guidelines or contact customer support for compatible replacement batteries and instructions.
Warning: Battery replacement should only be performed by qualified personnel. Improper replacement can lead to hazards.
7.2. Cleaning
Regularly clean the exterior of the UPS with a soft, dry cloth. Do not use liquid or aerosol cleaners. Ensure ventilation openings are free from dust and debris to maintain proper airflow.
8. Troubleshooting
If you encounter issues with your UPS, consult the table below for common problems and solutions.
| Problem | Possible Cause | Solution |
|---|---|---|
| UPS does not turn on. | No input power; Battery discharged. | Ensure the power cord is securely plugged into a live wall outlet. Allow the UPS to charge for several hours. |
| UPS beeps continuously in AC mode. | Overload condition. | Reduce the load by unplugging non-essential devices from the battery backup outlets. |
| Short backup time. | Battery is old or not fully charged. | Allow the UPS to charge for 8-12 hours. If the problem persists, consider replacing the battery. |
| Red fault indicator is on. | Internal fault. | Turn off the UPS, unplug all connected devices, and then unplug the UPS from the wall. Wait 5 minutes, then plug it back in and turn it on. If the fault persists, contact support. |
9. Technical Specifications
| Feature | Specification |
|---|---|
| Brand | Nilox |
| Model | NXGCLIO8501X5V2 |
| Power Output (VA/W) | 850 VA / 595 W |
| Technology | Line Interactive |
| Input Voltage | 232 Volts (Nominal) |
| Battery Type | Sealed Lead Acid (12V, 5Ah) |
| Typical Backup Time | 5 Minutes (at typical load) |
| Recharge Time | 30.25 Hours (to 90% capacity) |
| Outlets | 6 Schuko (3 Battery Backup, 3 Surge Protected) |
| Dimensions (L x W x H) | 37.5 x 23.5 x 14 cm |
| Weight | 3 Kilograms |
| Material | Plastic |
10. Warranty and Support
10.1. Warranty Information
The Nilox UPS Office Premium Line Interactive 850VA/595W comes with a 3-year warranty on electronic parts from the date of purchase. This warranty covers defects in materials and workmanship under normal use. Please retain your proof of purchase for warranty claims. The warranty typically does not cover consumable parts like batteries, which have a limited lifespan.
10.2. Customer Support
For technical assistance, warranty claims, or further inquiries, please contact Nilox customer support through their official website or the retailer where the product was purchased. Have your model number (NXGCLIO8501X5V2) and proof of purchase ready when contacting support.