1. Introduction
Thank you for choosing the MEDION MD 18085 Cordless Cyclonic 2-in-1 Stick Vacuum Cleaner. This manual provides essential information for the safe and effective use, assembly, operation, and maintenance of your appliance. Please read these instructions thoroughly before first use and keep them for future reference.
The MD 18085 is designed for dry vacuuming of dust, crumbs, and lint from smooth floors, short-pile carpets, upholstery, and car interiors. It features a powerful 120W motor, two suction power levels, and a motorized brush with LED lighting for thorough cleaning.
2. Important Safety Instructions
To reduce the risk of fire, electric shock, or injury, always follow basic safety precautions when using an electrical appliance.
- Read all instructions before using the appliance.
- This appliance is for household use only. Do not use outdoors or on wet surfaces.
- Do not allow the appliance to be used as a toy. Close attention is necessary when used by or near children.
- Use only as described in this manual. Use only manufacturer's recommended attachments.
- Do not use with a damaged cord or plug. If the appliance is not working as it should, has been dropped, damaged, left outdoors, or dropped into water, return it to a service center.
- Do not pull or carry by cord, use cord as a handle, close a door on cord, or pull cord around sharp edges or corners. Do not run appliance over cord. Keep cord away from heated surfaces.
- Do not unplug by pulling on cord. To unplug, grasp the plug, not the cord.
- Do not handle plug or appliance with wet hands.
- Do not put any object into openings. Do not use with any opening blocked; keep free of dust, lint, hair, and anything that may reduce airflow.
- Keep hair, loose clothing, fingers, and all parts of body away from openings and moving parts.
- Do not pick up anything that is burning or smoking, such as cigarettes, matches, or hot ashes.
- Do not use to pick up flammable or combustible liquids, such as gasoline, or use in areas where they may be present.
- Do not pick up toxic material, such as chlorine bleach, ammonia, or drain cleaner.
- Do not use without dust cup and/or filters in place.
- Turn off all controls before unplugging.
- Use extra care when cleaning on stairs.
- Do not charge the appliance outdoors.
- Use only the charger specified by the manufacturer.
3. Package Contents
Carefully unpack all items and ensure you have received all components listed below. If any parts are missing or damaged, contact customer support.
- MEDION MD 18085 Cordless Cyclonic Vacuum Cleaner (main unit)
- Floor Brush (motorized with LED lighting)
- Multi-function Nozzle (includes upholstery brush and crevice tool)
- Wall Mount
- Power Adapter

Figure 3.1: Multi-function nozzle and wall mount accessories.
4. Setup
4.1 Assembly
- Attach the extension tube to the main handheld unit until it clicks into place.
- Connect the floor brush to the other end of the extension tube, ensuring it is securely fastened.
- Alternatively, for handheld use, attach the multi-function nozzle directly to the main unit.

Figure 4.1: Fully assembled vacuum cleaner.
4.2 Charging the Battery
Before first use, fully charge the vacuum cleaner's battery. The battery provides approximately 30 minutes of runtime on a full charge.
- Connect the power adapter to the charging port on the main unit.
- Plug the power adapter into a suitable wall outlet.
- The charging indicator lights will illuminate, showing the charging status. Allow the unit to charge until the indicators show a full charge.

Figure 4.2: Charging the vacuum cleaner.
4.3 Wall Mount Installation
The included wall mount allows for convenient storage and charging.
- Choose a suitable location near a power outlet, ensuring it is at an appropriate height for easy access.
- Mark the drilling points on the wall using the wall mount as a template.
- Drill holes and insert wall plugs (if necessary, depending on wall material).
- Secure the wall mount to the wall using appropriate screws.
- Hang the vacuum cleaner on the wall mount.
5. Operating Instructions
5.1 Power On/Off and Suction Levels

Figure 5.1: Handheld unit with controls.
- To turn on the vacuum cleaner, press the power button located on the handle. The appliance will start in the standard suction mode.
- To switch to the higher suction power level, press the power button again.
- To turn off the vacuum cleaner, press the power button a third time.
5.2 Using Attachments
- Floor Brush: Use the motorized floor brush for cleaning hard floors and short-pile carpets. The integrated LED lights illuminate dark areas, ensuring no dust is missed.
- Multi-function Nozzle: This attachment combines an upholstery brush and a crevice tool. Use the upholstery brush for cleaning furniture, curtains, and car seats. The crevice tool is ideal for narrow gaps, corners, and edges.
6. Maintenance
Regular maintenance ensures optimal performance and extends the lifespan of your vacuum cleaner.
6.1 Emptying the Dust Container
Empty the dust container regularly, preferably after each use, to maintain strong suction power.
- Ensure the vacuum cleaner is turned off.
- Locate the dust container release button, usually near the handle.
- Press the button to detach the dust container from the main unit.
- Hold the dust container over a waste bin and open its bottom flap to release the collected dust and debris.
- Close the flap and reattach the dust container to the main unit until it clicks securely.
6.2 Cleaning the Filter
The cartridge filter should be cleaned periodically to prevent clogging and maintain suction efficiency.
- Remove the dust container as described above.
- Carefully remove the filter from inside the dust container.
- Tap the filter gently over a waste bin to remove loose dust. For a more thorough clean, rinse the filter under cold running water.
- Allow the filter to air dry completely for at least 24 hours before reinserting it. Do not use the vacuum cleaner with a wet filter.
- Once dry, place the filter back into the dust container and reattach the container to the main unit.
6.3 Cleaning Attachments
Regularly check and clean the floor brush and other nozzles.
- Floor Brush: Remove any tangled hair or fibers from the brush roll using scissors or a brush cleaning tool. Ensure the brush roll spins freely.
- Other Nozzles: Wipe down the multi-function nozzle and crevice tool with a damp cloth to remove any dirt or debris.
7. Troubleshooting
If you encounter issues with your vacuum cleaner, refer to the following table for common problems and solutions.
| Problem | Possible Cause | Solution |
|---|---|---|
| Vacuum cleaner does not turn on. | Battery is not charged. | Charge the battery fully. |
| Power button not pressed correctly. | Ensure the power button is pressed firmly. | |
| Low suction power. | Dust container is full. | Empty the dust container. |
| Filter is clogged. | Clean or replace the filter. | |
| Hose or nozzle is blocked. | Check for and remove any blockages in the extension tube or attachments. | |
| Brush roll not spinning. | Hair or debris tangled in brush roll. | Clean the brush roll. |
| Floor brush not properly connected. | Ensure the floor brush is securely attached to the extension tube. |
8. Specifications
| Feature | Specification |
|---|---|
| Model Number | MD 18085 |
| Brand | MEDION |
| Power | 120 Watts |
| Voltage | 21.6 Volts |
| Suction Power | 7 kPa (approximate, depending on mode) |
| Runtime | Up to 30 minutes |
| Power Source | Battery powered |
| Form Factor | Stick, Handheld (2-in-1) |
| Special Feature | Bagless, Cordless, Motorized brush with LED |
| Filter Type | Cartridge |
| Surface Recommendation | Hard floor, Carpet |
| Color | Grey |
9. Warranty and Support
For warranty information or technical support, please refer to the warranty card included with your product or visit the official MEDION website. Keep your proof of purchase for any warranty claims.
If you have questions or require assistance, please contact MEDION customer service. Contact details can typically be found on the manufacturer's website or in the product packaging.