1. Introduction

This user manual provides essential information for the safe and efficient operation, installation, and maintenance of your Remko RKL 495 DC Mobile Split Air Conditioner. Please read this manual thoroughly before operating the unit and retain it for future reference.

The Remko RKL 495 DC is a powerful mobile split air conditioning unit designed to provide effective cooling for various indoor spaces. Its inverter technology ensures maximum comfort by minimizing temperature fluctuations.

2. Safety Instructions

Always adhere to the following safety precautions to prevent injury or damage to the unit.

  • Ensure the power supply matches the unit's requirements.
  • Do not block air inlets or outlets.
  • Keep the unit away from heat sources and direct sunlight.
  • Do not operate with wet hands.
  • Unplug the unit before cleaning or maintenance.
  • Only qualified personnel should perform repairs.
  • This appliance uses R32 refrigerant. Handle with care and ensure proper ventilation during installation and maintenance.

3. Product Overview

The Remko RKL 495 DC consists of an indoor unit (evaporator) and an outdoor unit (condenser) connected by a refrigerant line.

Remko RKL 495 DC Mobile Split Air Conditioner, showing both indoor and outdoor units connected by a flexible hose.

Figure 3.1: Remko RKL 495 DC Mobile Split Air Conditioner. The image displays the white indoor unit on the left with control panel and air vents, connected by a flexible grey hose to the smaller white outdoor unit on the right, which has a large gridded vent.

3.1 Components

  • Indoor Unit: Houses the evaporator, fan, and control panel.
  • Outdoor Unit: Contains the condenser, compressor, and fan.
  • Refrigerant Line: Connects the indoor and outdoor units, total length 3 meters, separable via quick-coupling system.
  • Remote Control: Infrared remote for convenient operation. (Requires 2 AAA batteries, not included)
  • Integrated Condensate Pump: Automatically removes condensed water.

3.2 Control Panel and Display

The electronic control system features a digital display for temperature and operating status. Refer to the markings on the unit for specific button functions.

4. Setup and Installation

The Remko RKL 495 DC is designed for easy setup. However, due to its weight (57.3 kg), it is recommended that two people handle the unit during unboxing and positioning.

4.1 Unpacking

  • Carefully remove the unit from its packaging.
  • Check for any signs of damage during transit. If damage is found, contact your supplier immediately.
  • Retain packaging materials for future transport or storage.

4.2 Positioning the Unit

Place the indoor unit on a flat, stable surface. The outdoor unit should be placed outside, ensuring the connecting hose can reach without kinks or excessive tension. The standard equipment includes a hanging device for wall mounting the outdoor unit.

Remko RKL 495 DC indoor unit placed next to a glass door, with the outdoor unit visible outside through the glass.

Figure 4.1: Proper placement of the Remko RKL 495 DC. The indoor unit is positioned inside a room near a large glass door, allowing the connecting hose to pass through to the outdoor unit, which is visible outside.

4.3 Connecting the Refrigerant Line

The 3-meter refrigerant line is equipped with a quick-coupling system for easy connection and disconnection. Ensure the connections are secure to prevent refrigerant leaks. The hose diameter is approximately 4 cm.

Note: While the quick-coupling system allows for disconnection, frequent disconnection and reconnection should be minimized to preserve the integrity of the seals and refrigerant charge. For detailed instructions on connecting/disconnecting the quick-coupling, refer to the manufacturer's specific video tutorials if available, or consult a qualified technician.

4.4 Power Connection

Connect the power cable to a standard 230V electrical outlet. Ensure the outlet is properly grounded and can handle the unit's power consumption (1.37 KW).

5. Operating Instructions

The Remko RKL 495 DC can be operated via its electronic control panel or the supplied infrared remote control.

5.1 Turning On/Off

  • Press the Power button on the control panel or remote control to turn the unit on or off.

5.2 Mode Selection

Use the Mode button to cycle through available operating modes:

  • Cooling Mode: For active cooling. Set desired temperature.
  • Fan Mode: Circulates air without cooling. Note: Fan mode has only one speed.
  • Automatic Mode: The unit automatically selects the operating mode based on the ambient temperature and set temperature.

5.3 Temperature Setting

Use the Temperature Up/Down buttons to adjust the desired room temperature. The digital display will show the set temperature.

5.4 Fan Speed Adjustment

In cooling mode, use the Fan Speed button to select between multiple fan speeds (e.g., Low, Medium, High). This function is not available in fan-only mode.

5.5 Swing Function

Activate the Swing function to enable automatic vertical oscillation of the air outlet louvers, ensuring even air distribution. The air outlet direction can also be continuously adjusted manually.

5.6 Timer Function

The unit features a programmable 24-hour timer. Refer to the remote control or control panel instructions for setting the timer to automatically turn the unit on or off at specified times.

5.7 Remote Control Usage

The infrared remote control allows for convenient operation from a distance. Ensure direct line of sight to the indoor unit's receiver. Insert 2 AAA alkaline batteries (not included) into the remote control, observing polarity.

6. Maintenance and Cleaning

Regular maintenance ensures optimal performance and extends the lifespan of your air conditioner. Always unplug the unit before performing any cleaning or maintenance.

6.1 Air Filter Cleaning

The unit is equipped with a removable air filter. Clean the air filter regularly (e.g., every two weeks or more frequently depending on usage) to maintain air quality and cooling efficiency.

  1. Turn off and unplug the unit.
  2. Locate and remove the air filter from the indoor unit.
  3. Clean the filter using a vacuum cleaner or wash it with lukewarm water and mild detergent.
  4. Allow the filter to dry completely before reinserting it.

6.2 Exterior Cleaning

Wipe the exterior of both units with a soft, damp cloth. Do not use harsh chemicals, abrasives, or solvents, as these can damage the surface.

6.3 Condensate Drainage

The integrated condensate pump automatically handles water removal. However, if the unit is to be stored for an extended period, it is advisable to tilt the indoor unit slightly backward to ensure any residual water drains completely through the hose.

6.4 Outdoor Unit Coil Cleaning

Periodically inspect the outdoor unit's condenser coils for dust, pollen, and debris. Ensure the unit is unplugged before cleaning. The coils can be gently cleaned with a soft brush or a low-pressure water spray. Avoid bending the delicate fins.

7. Troubleshooting

Before contacting customer support, please refer to the following table for common issues and their solutions.

ProblemPossible CauseSolution
Unit does not turn on.No power supply; power cord unplugged; circuit breaker tripped.Check power connection; reset circuit breaker.
Insufficient cooling.Dirty air filter; blocked air inlets/outlets; room too large; windows/doors open.Clean air filter; clear obstructions; ensure room is sealed; verify unit capacity for room size.
Unusual noise.Unit not level; loose parts; fan obstruction.Ensure unit is on a flat surface; check for loose components; inspect fan for obstructions.
Water leakage.Condensate drain blocked or hose kinked.Check and clear condensate drain; straighten hose.
Remote control not working.Dead batteries; no line of sight to receiver.Replace batteries; ensure clear path to unit's receiver.

If the problem persists after attempting these solutions, please contact qualified service personnel.

8. Technical Specifications

FeatureSpecification
ModelRKL 495 DC
Part Number1616495
Cooling Capacity4.3 kW (15000 BTU)
Power Consumption1.37 KW
Voltage230 Volts
Dimensions (L x W x H)46.99 x 33.5 x 69.49 cm (Indoor Unit)
Weight57.3 kg
Noise Level62 dB
Refrigerant Line Length3000 Millimeters (3 meters)
Covered Area (approx.)Up to 80 m²
Required Batteries (Remote)2 AAA (Alkaline)

9. Warranty and Support

For warranty information and customer support, please refer to the documentation provided with your purchase or contact your retailer. Keep your proof of purchase for warranty claims.

Manufacturer: Remko

Return Policy: 30 days (refund/replacement) as per seller's policy.

For technical assistance or service, it is recommended to contact authorized Remko service centers or qualified technicians.

© 2024 Remko. All rights reserved.

This manual is subject to change without notice.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.