The OneTouch Ultra2 Blood Glucose Monitoring System is designed to help individuals with diabetes monitor their blood glucose levels quickly and accurately. Regular monitoring is a key part of managing diabetes effectively. This system provides reliable results, allowing you to track your glucose trends and make informed decisions about your health in consultation with your healthcare professional.
Key features include a large, easy-to-read display with backlight, and the ability to store and review before and after meal results and averages.

Image: The OneTouch Ultra2 Blood Glucose Monitoring System, including the meter, lancing device, and a box of test strips, all neatly arranged with its carrying case.
What's Included
Your OneTouch Ultra2 Blood Glucose Monitoring System package typically includes the following components:
- OneTouch Ultra2 Meter: The main device for reading blood glucose levels.
- OneTouch Delica Plus Lancing Device: Used to obtain a blood sample.
- OneTouch Ultra2 Meter Owner's Booklet: Detailed instructions and information about your system.
- OneTouch Ultra2 Meter Getting Started Guide: A quick reference for initial setup.
- Carrying Case: For convenient storage and transport of your system components.

Image: A view inside the open carrying case, showing the OneTouch Ultra2 meter, lancing device, owner's booklet, and getting started guide, illustrating all included items.
Setup
Before using your OneTouch Ultra2 meter for the first time, follow these setup steps:
- Insert Batteries: Open the battery compartment on the back of the meter and insert the two C batteries (included), ensuring correct polarity. Close the compartment securely.
- Set Date and Time: Turn on the meter. The display will prompt you to set the current date and time. Use the arrow buttons to adjust the values and the OK button to confirm each setting.
- Prepare Lancing Device: Insert a new, sterile lancet into the OneTouch Delica Plus Lancing Device. Twist off the protective cap from the lancet. Replace the lancing device cap. Adjust the depth setting on the lancing device according to your comfort level and skin type.

Image: A person's hands are shown preparing the OneTouch Delica Plus Lancing Device, demonstrating the process of inserting a lancet and twisting off its protective cap.
Operating Instructions
Performing a Blood Glucose Test
Follow these steps to perform a blood glucose test:
- Wash Hands: Wash your hands thoroughly with soap and warm water. Dry them completely.
- Insert Test Strip: Insert a OneTouch Ultra test strip into the test strip port of the meter. The meter will turn on automatically.
- Obtain Blood Sample: Use the lancing device to prick the side of your fingertip. Gently squeeze your finger to form a small drop of blood.
- Apply Blood Sample: Touch the tip of the test strip to the blood drop. The blood will be drawn into the strip. Do not apply blood to the top of the strip.
- Read Results: The meter will display your blood glucose result in approximately 5 seconds.
- Record Results: The meter automatically stores your results. You can also manually record them in a logbook.

Image: An informational graphic highlighting the features of the lancing device, emphasizing its silicone-coating for smooth gliding and comfortable testing.
Understanding Your Results
The OneTouch Ultra2 meter provides clear numerical results. It also allows you to mark readings as "before meal" or "after meal" to help you understand how food affects your blood glucose. The meter can calculate and display averages for these categories over time.

Image: A OneTouch meter displaying a blood glucose reading, accompanied by a colorful chameleon graphic and text promoting the use of colors for diabetes management, indicating visual cues for glucose levels.
Maintenance and Care
Cleaning the Meter
To clean your OneTouch Ultra2 meter, wipe the exterior with a soft, damp cloth. Do not immerse the meter in water or use harsh cleaning agents. Ensure the test strip port remains free of debris.
Storage
Store your OneTouch Ultra2 meter and test strips in their original containers in a cool, dry place, away from direct sunlight, extreme temperatures, and humidity. Always keep the test strip vial cap tightly closed to protect the strips from moisture.
Battery Replacement
The meter uses two C batteries. When the low battery indicator appears on the display, replace both batteries simultaneously. Refer to the Owner's Booklet for detailed instructions on battery replacement.
Troubleshooting
If you encounter issues with your OneTouch Ultra2 Blood Glucose Monitoring System, refer to the table below for common problems and their solutions. For issues not listed, consult your Owner's Booklet or contact customer support.
| Issue | Possible Cause / Solution |
|---|---|
| Error Code E-1 | Test strip improperly inserted or damaged. Remove and reinsert the test strip, or use a new one. |
| Inaccurate Readings | Check test strip expiration date. Ensure proper blood sample application. Verify meter and strip are at room temperature. Consult your healthcare professional if discrepancies persist. |
| Meter Does Not Turn On | Batteries may be low or incorrectly inserted. Replace batteries or ensure they are properly seated. |
| Insufficient Blood Sample | Ensure a sufficient blood drop is applied to the test strip. Do not add more blood after the test has started. Use a new strip if necessary. |
Specifications
- Model Name: Ultra 2
- Brand: ONETOUCH
- Product Dimensions: 3.85 x 3.02 x 6.41 inches; 5.61 ounces
- Batteries: 2 C batteries (included)
- Battery Cell Composition: Lithium
- Operating Time: 5 Seconds (for test results)
- Manufacturer: LifeScan Inc.
- ASIN: B07Y1C68K7
- UPC: 353885011853
Warranty and Support
For detailed warranty information regarding your OneTouch Ultra2 Blood Glucose Monitoring System, please refer to the Owner's Booklet provided with your product. The booklet contains specific terms, conditions, and duration of the warranty.
Should you require technical assistance, have questions about your meter, or need to order replacement parts or supplies, please contact OneTouch Customer Support. Contact details can typically be found in your Owner's Booklet or on the official OneTouch website.
Always ensure you are using genuine OneTouch Ultra test strips with your OneTouch Ultra2 meter for accurate results and to maintain warranty validity.