1. Introduction

The RIGOL DS1202Z-E is a high-performance 200 MHz digital oscilloscope designed for a wide range of applications including research and development, maintenance, and educational laboratory settings. It offers advanced features such as a 1 GSa/s real-time sample rate, 24 Mpts memory depth, and a 7-inch high-definition display, providing clear and detailed waveform analysis.

2. Key Features

  • Bandwidth and Sampling: 200 MHz bandwidth with 1 GSa/s real-time sample rate.
  • Memory Depth: 24 Mpts memory for extended signal capture and detailed analysis.
  • Multifunctional Measurement: Integrates a frequency counter and supports protocol decoding for RS232/UART, I2C, and SPI. Includes FFT analysis and automatic measurement functions.
  • Waveform Recording: Features waveform recording and playback to capture signal variations and identify faults or anomalies.
  • High-Definition Display: Equipped with a 7-inch TFT display offering 256 gray levels, providing a visual effect similar to phosphor screens for clear waveform details.
  • Remote Control & Development Support: USB and LAN ports enable remote control from a PC. Compatible with SCPI commands and integrates with LabVIEW, Visual Basic, and Visual C++.

3. Product Overview

3.1 Front Panel

The front panel of the DS1202Z-E features a 7-inch color display, control buttons, and input connectors. The intuitive layout allows for easy access to all primary functions.

Front view of the RIGOL DS1202Z-E Digital Oscilloscope, showing the 7-inch display, control knobs, and input channels.

Figure 3.1: Front Panel of the DS1202Z-E Oscilloscope

3.2 Rear Panel

The rear panel provides connectivity options for power, USB, and LAN for remote operation and data transfer.

Rear view of the RIGOL DS1202Z-E Digital Oscilloscope, showing power input, USB, and LAN ports.

Figure 3.2: Rear Panel of the DS1202Z-E Oscilloscope

3.3 Dimensions

The compact design of the oscilloscope makes it suitable for various workspaces.

Diagram showing the dimensions of the RIGOL DS1202Z-E Oscilloscope: 313.1mm width, 160.8mm height, 122.4mm depth, and 2.9Kg weight.

Figure 3.3: DS1202Z-E Dimensions

4. Setup

  1. Unpacking: Carefully remove the oscilloscope and all accessories from the packaging.
  2. Power Connection: Connect the provided power cord to the oscilloscope's power input on the rear panel and then to a suitable AC power outlet.
  3. Power On: Press the mechanical power button on the front panel to turn on the instrument.
  4. Probe Connection: Connect the oscilloscope probes to the CH1 and CH2 input connectors on the front panel. Ensure a secure connection.
  5. Probe Compensation: Perform probe compensation as described in the detailed user manual to ensure accurate measurements.

5. Operating Instructions

5.1 Basic Waveform Display

After powering on, connect a signal to one of the input channels. Use the vertical scale (Volts/Div) and horizontal scale (Time/Div) knobs to adjust the waveform display. The position knobs allow you to move the waveform vertically and horizontally.

Oscilloscope display showing yellow and white waveforms on a black background with grid lines and measurement data.

Figure 5.1: Basic Waveform Display

5.2 Triggering

The trigger system stabilizes repetitive waveforms and captures single-shot events. Use the Trigger Level knob to set the trigger point. Various trigger modes (Edge, Pulse, Video, Slope, etc.) are available via the 'Trigger' menu.

5.3 Serial Bus Decoding

The DS1202Z-E supports decoding of common serial protocols. Access the 'Decode' menu to select the protocol (RS232/UART, I2C, SPI) and configure parameters. The decoded data will be displayed on the screen, simplifying debugging of serial communications.

Oscilloscope display showing decoded serial data for I2C protocol, with 'RIGOL' text being decoded.

Figure 5.3: Serial Bus Decoding (I2C Example)

5.4 Waveform Recording and Playback

Utilize the waveform recording feature to capture and store up to 5,000 frames of trigger events. This allows for later review and analysis of intermittent events or long-duration signals.

Digital oscilloscope display showing multiple waveforms with signal traces in yellow, blue, and pink on a black background with grid lines.

Figure 5.4: Waveform Recording and Playback Interface

5.5 FFT Analysis

The Fast Fourier Transform (FFT) function allows you to analyze signals in the frequency domain. This is useful for identifying harmonics, noise, and other frequency components. Access FFT from the 'Math' menu.

Oscilloscope display showing a green waveform on a black background with interface elements visible along the screen edges, illustrating FFT analysis.

Figure 5.5: FFT Analysis Display

5.6 Product Features Overview Video

Video 5.6: A brief overview of the RIGOL DS1202Z-E oscilloscope's key features, including deep memory, capture rate, waveform tracking, and serial bus decoding capabilities.

6. Specifications

FeatureSpecification
BrandRigol
Power SourceCorded Electric
StyleDigital
ColorWhite
Item Dimensions (LxWxH)31.3 x 16.1 x 12.2 cm
Minimum Operating Voltage100 Volts
Upper Operating Temperature122 Degrees Fahrenheit
Measurement TypeMultimeter
Achieved SpecificationsFCC, IEC 1010, IEC 61010-1:2000-1
ModelDS1202Z-E
UPC764560091433
ManufacturerRIGOL
Global Trade Identification Number00764560091433
Part NumberRIGOL DS1202Z-E
Country of OriginChina
Sales Unit Volume/Weight1.0 Count

7. What's in the Box

The RIGOL DS1202Z-E package includes the following components:

  • Main Unit (DS1202Z-E Digital Oscilloscope)
  • 2 x Passive Probes (350MHz)
  • Power Cord (EU)
  • USB A-B Data Cable
  • Warranty Card
  • Calibration Certificate
  • Declaration of Conformity
Contents of the RIGOL DS1202Z-E box, including the main oscilloscope unit, two probes, power cable, USB cable, and documentation.

Figure 7.1: Package Contents

8. Troubleshooting

This section provides general guidance for common issues. For detailed troubleshooting steps, refer to the comprehensive user manual available on the Rigol website.

  • No Power: Ensure the power cord is securely connected to both the oscilloscope and the power outlet. Check the power button.
  • No Waveform Display: Verify that probes are correctly connected to the input channels and the signal source. Adjust vertical and horizontal scales. Check trigger settings.
  • Unstable Waveform: Adjust the trigger level and trigger mode. Ensure the trigger source is correctly selected.
  • Incorrect Measurements: Perform probe compensation. Check probe attenuation settings on the oscilloscope.

9. Maintenance

Proper maintenance ensures the longevity and accuracy of your oscilloscope.

  • Cleaning: Use a soft, dry cloth to clean the exterior of the instrument. Do not use abrasive cleaners or solvents.
  • Storage: Store the oscilloscope in a clean, dry environment away from direct sunlight and extreme temperatures.
  • Calibration: Regular calibration by authorized service centers is recommended to maintain measurement accuracy.

10. Warranty and Support

The RIGOL DS1202Z-E Digital Oscilloscope comes with a 3-year warranty. Rigol offers 24-hour technical support to assist with any product-related inquiries or issues. For service or support, please contact Rigol customer service or visit the official Rigol website.

For more information, please visit Rigolna.com.

© 2026 Rigol. All rights reserved.

Related Documents - DS1202Z-E

Preview RIGOL DS1000Z-E Series Digital Oscilloscope: Features, Specifications, and Accessories
Detailed overview of the RIGOL DS1000Z-E Series digital oscilloscopes, including features like UltraVision technology, key specifications, compatible probes and accessories, and regulatory compliance.
Preview RIGOL DS1000Z-E Series Digital Oscilloscope Quick Guide
A quick guide to the RIGOL DS1000Z-E Series Digital Oscilloscope, covering safety, operation, and features.
Preview RIGOL DS1000Z-E Series Digital Oscilloscope User Guide
Comprehensive user guide for the RIGOL DS1000Z-E Series Digital Oscilloscope, covering safety, operation, features, and troubleshooting. Learn how to use this high-performance instrument for various applications.
Preview RIGOL DS1000Z-E Series Oscilloscopes Performance Verification Manual
This manual provides detailed procedures for verifying the performance of RIGOL DS1000Z-E series oscilloscopes. It covers essential tests such as input impedance, DC gain accuracy, bandwidth, timebase accuracy, and zero point offset, along with necessary setup, technical specifications, and data recording forms. The procedures are designed to be followed using a Fluke 9500B calibrator.
Preview RIGOL DS1000Z-E Series Digital Oscilloscope User Guide
Comprehensive user guide for the RIGOL DS1000Z-E Series Digital Oscilloscope, detailing safety, operation, features, and troubleshooting for professional applications in various technical fields.
Preview RIGOL MSO8000 Series Digital Oscilloscope User Guide
Comprehensive user guide for the RIGOL MSO8000 Series Digital Oscilloscope, covering setup, operation, measurements, triggering, and advanced features. Learn to maximize the capabilities of your RIGOL oscilloscope.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.