Vikye T3100 X100

Vikye T3100 X100 100MHz High Voltage Oscilloscope Probe User Manual

Model: T3100 X100

Introduction

This manual provides essential information for the safe and effective use of the Vikye T3100 X100 100MHz High Voltage Oscilloscope Probe. Please read these instructions thoroughly before operating the device to ensure proper functionality and user safety.

Safety Information

Warning: This probe is designed for high voltage measurements. Improper use can result in electric shock, injury, or damage to equipment. Always adhere to the following safety guidelines:

Product Overview

The Vikye T3100 X100 is a high-voltage oscilloscope probe designed for measuring signals up to 100 MHz with an attenuation ratio of 100:1. It features a robust design suitable for various electrical testing applications.

Vikye T3100 X100 Oscilloscope Probe

Figure 1: Overall view of the Vikye T3100 X100 High Voltage Oscilloscope Probe, showing the probe body, cable, and BNC connector.

Components:

Close-up of the probe tip

Figure 2: Close-up view of the probe tip, showing its pointed design for precise contact.

Close-up of the BNC connector

Figure 3: Close-up view of the BNC connector, which securely attaches to the oscilloscope input.

Setup

  1. Connect to Oscilloscope: Align the BNC connector of the probe with the input channel of your oscilloscope. Push and twist clockwise until it locks securely.
  2. Connect Ground Lead: Attach the alligator clip of the probe's ground lead to a reliable ground point on the circuit under test. Ensure a solid electrical connection.
  3. Compensation Adjustment:
    • Connect the probe tip to the oscilloscope's probe compensation output (usually a square wave signal).
    • Observe the square wave on the oscilloscope screen.
    • Using a non-metallic adjustment tool (often included with oscilloscopes), carefully turn the compensation adjustment screw on the probe body until the square wave appears flat-topped, without overshoot or undershoot. This ensures accurate signal reproduction.
Probe connected to oscilloscope and circuit

Figure 4: Illustration of the probe connected to an oscilloscope and a circuit board for measurement.

Operating Instructions

  1. Select Oscilloscope Channel: Choose the appropriate input channel on your oscilloscope.
  2. Set Attenuation: Ensure your oscilloscope's channel input setting is set to X100 to match the probe's attenuation ratio. If your oscilloscope does not have an X100 setting, you will need to manually multiply the displayed voltage by 100.
  3. Connect Probe Tip: Carefully touch the probe tip to the desired test point on the circuit.
  4. Observe Waveform: Adjust the oscilloscope's vertical (Volts/Div) and horizontal (Time/Div) settings to obtain a stable and clear waveform display.
  5. Interpret Readings: Remember that the voltage displayed on the oscilloscope screen is 1/100th of the actual voltage at the probe tip due to the X100 attenuation.

Maintenance

Troubleshooting

Specifications

ParameterValue
ModelT3100 X100
BrandVikye
Attenuation RatioX100 (100:1)
Bandwidth100 MHz
Input Resistance (typical)100 MΩ (when connected to 1 MΩ oscilloscope input)
Input Capacitance (typical)3.5 pF
Maximum Input Voltage (typical)2000 V (DC + Peak AC)
Cable Length120 cm

Note: Typical specifications are provided for general guidance. Actual performance may vary.

Warranty and Support

For warranty information and technical support, please refer to the documentation provided at the time of purchase or contact your retailer. Keep your purchase receipt as proof of purchase.