Melitta 1025-08

Melitta Look Timer 1025-08 Filter Coffee Machine User Manual

Model: 1025-08

1. Introduction

Thank you for choosing the Melitta Look Timer 1025-08 Filter Coffee Machine. This manual provides important information for the safe and efficient operation, maintenance, and troubleshooting of your appliance. Please read these instructions carefully before first use and keep them for future reference.

Important Safety Instructions

2. Product Overview

Familiarize yourself with the components of your Melitta Look Timer 1025-08 coffee machine.

Melitta Look Timer 1025-08 Filter Coffee Machine

Image 2.1: Front view of the Melitta Look Timer 1025-08 coffee machine, showing the main unit, glass carafe, control panel, and water tank.

Melitta Look Timer 1025-08 Features Overview

Image 2.2: Overview of key features including the AromaSelector, removable water tank, swivel filter with drip stop, and digital timer display.

Components:

  1. Water Tank (removable)
  2. Lid for Water Tank
  3. AromaSelector Dial
  4. Swivel Filter Holder
  5. Filter Insert
  6. Drip Stop Mechanism
  7. Glass Carafe with Lid
  8. Heating Plate
  9. Control Panel with Display and Buttons (h, m, TIMER, CALC, ON/OFF)
  10. Power Cord

3. Setup and First Use

3.1 Unpacking and Initial Cleaning

3.2 First Operation (Cleaning Cycle)

Before brewing coffee for the first time, run two full cycles with only water to clean the internal components.

  1. Fill the removable water tank with fresh, cold water up to the "10 cups" mark.
    Removing Water Tank

    Image 3.1: A hand demonstrating the removal of the water tank for easy filling.

  2. Place the empty glass carafe with its lid on the heating plate.
  3. Press the ON/OFF button. The indicator light will illuminate.
  4. Allow the water to run through completely.
  5. Discard the water and repeat the process once more with fresh water.

3.3 Setting Water Hardness (for Descaling Reminder)

The coffee machine has a descaling reminder function. For optimal performance, set the water hardness level according to your local water supply.

4. Operating Instructions

4.1 Brewing Coffee

  1. Fill the removable water tank with the desired amount of fresh, cold water. The tank has markings for cups.
  2. Insert a Melitta filter paper (size 1x4 or similar) into the filter insert.
  3. Add the desired amount of ground coffee into the filter paper. A general guideline is one level tablespoon of coffee per cup (125 ml).
  4. Close the swivel filter holder. Ensure the glass carafe with its lid is correctly placed on the heating plate.
  5. Adjust the AromaSelector dial to your preferred coffee strength (mild to strong).
    AromaSelector Dial

    Image 4.1: Top view showing the AromaSelector dial for adjusting coffee strength.

  6. Press the ON/OFF button. The indicator light will illuminate, and the brewing process will begin.
  7. Once brewing is complete, the coffee machine will automatically switch to the keep-warm function.
  8. The appliance will automatically switch off after a preset time (e.g., 20, 40, or 60 minutes, depending on settings).

4.2 Using the Timer Function

The timer function allows you to program the coffee machine to start brewing at a specific time.

Control Panel with Timer Buttons

Image 4.2: Close-up of the control panel, highlighting the digital display and the 'h', 'm', and 'TIMER' buttons.

  1. First, set the current time:
    • Press and hold the h button to set the hour.
    • Press and hold the m button to set the minute.
  2. Prepare the coffee machine for brewing as described in section 4.1 (fill water, add filter and coffee).
  3. Press the TIMER button. The display will show "TIMER" and the previously set timer start time (or default).
  4. Use the h and m buttons to set the desired start time for brewing.
  5. Press the TIMER button again to activate the timer. The timer indicator will light up.
  6. The coffee machine will automatically start brewing at the programmed time.
  7. To cancel the timer, press the TIMER button until the indicator light turns off.

5. Cleaning and Maintenance

Regular cleaning and descaling ensure optimal performance and extend the lifespan of your coffee machine.

5.1 Daily Cleaning

5.2 Descaling

The CALC button indicator will illuminate when descaling is required. The frequency of descaling depends on water hardness and usage.

  1. Ensure the coffee machine is unplugged and cooled down.
  2. Remove any used filter paper and coffee grounds.
  3. Fill the water tank with a descaling solution according to the descaler manufacturer's instructions. Melitta recommends using its own descaling products.
  4. Place the empty glass carafe with its lid on the heating plate.
  5. Press the CALC button. The descaling process will begin.
  6. Allow the descaling solution to run through completely.
  7. After the descaling cycle, run two full cycles with fresh, cold water to rinse the machine thoroughly.
  8. The CALC indicator will turn off once the descaling process is complete and the machine has been rinsed.

5.3 Setting Water Hardness (Detailed)

To adjust the water hardness setting for the descaling reminder:

6. Troubleshooting

Refer to this section for common issues and their solutions.

ProblemPossible CauseSolution
Coffee does not brew.
  • No water in the tank.
  • Appliance not plugged in.
  • Timer function activated but not yet reached.
  • Fill water tank.
  • Check power connection.
  • Wait for timer or deactivate it.
Coffee tastes weak or too strong.
  • Incorrect coffee-to-water ratio.
  • AromaSelector setting.
  • Adjust coffee grounds amount.
  • Adjust AromaSelector dial.
Water overflows from filter.
  • Too much coffee grounds.
  • Filter paper not correctly inserted.
  • Drip stop clogged.
  • Reduce coffee grounds.
  • Ensure filter paper is seated correctly.
  • Clean the drip stop mechanism.
CALC indicator light is on.
  • Descaling is required.
  • Perform a descaling cycle as described in section 5.2.

7. Technical Specifications

8. Warranty and Support

Melitta products are manufactured to high quality standards and come with a manufacturer's warranty. For specific warranty terms and conditions, please refer to the warranty card included with your product or visit the official Melitta website.

For technical support, spare parts, or service inquiries, please contact Melitta customer service. Contact information can typically be found on the Melitta website or on the product packaging.

Online Resources: www.melitta.com

Related Documents - 1025-08

Preview Melitta Easy Timer & EasyTop Timer Filter Coffee Maker User Manual
Comprehensive user manual for the Melitta Easy Timer and EasyTop Timer filter coffee makers, covering safety, operation, maintenance, and disposal information. Includes instructions for brewing coffee, setting the timer, and cleaning the appliance.
Preview Melitta AromaFresh Filter Coffee Maker Operating Instructions
Comprehensive guide to operating and maintaining the Melitta AromaFresh filter coffee maker, including setup, brewing, cleaning, and troubleshooting.
Preview Melitta LOOK Timer Coffee Maker - Operating Instructions & Guide
Comprehensive operating instructions and safety guide for the Melitta LOOK Timer coffee maker. Learn about setup, brewing, cleaning, descaling, timer functions, and warranty information.
Preview Melitta Enjoy Top Timer Coffee Maker: User Manual and Operating Instructions
Comprehensive user manual for the Melitta Enjoy Top Timer filter coffee maker, covering setup, operation, features like timer and Aroma Selector, cleaning, maintenance, and safety guidelines.
Preview Melitta Optima Timer Filter Coffee Maker User Manual and Guide
Comprehensive user manual for the Melitta Optima Timer filter coffee maker, covering setup, operation, safety instructions, coffee preparation, timer function, descaling, cleaning, and maintenance. Includes multilingual support.
Preview Melitta Easy Timer & EasyTop® Timer Coffee Maker User Manual
Comprehensive user manual for the Melitta Easy Timer and EasyTop® Timer filter coffee maker, covering safety instructions, operation, cleaning, and maintenance.