AERAULIQA PKV00005

AERAULIQA WKG150 Glass Application Kit

Model: PKV00005

Instruction Manual for QD-QS-QA 150 Vacuum Cleaners

1. Product Overview

The AERAULIQA WKG150 is a glass application kit designed for use with QD-QS-QA 150 series axial vacuum cleaners. This kit includes a fixed external grille and is identified by product code PKV00005. It serves as an essential accessory for integrating the vacuum cleaner system into glass panels.

Key Features:

  • Accessory for Aerauliqa QD-QA-QS 150 Axial Vacuum Cleaners.
  • Constructed from high-quality ABS (Acrylonitrile Butadiene Styrene) material.
  • Color: RAL9010 (Bianco Ral 9010).
  • Resistant to shock and UV radiation, ensuring durability.
  • Compatible with glass thickness ranging from 2 mm to 35 mm.
  • Requires a 172 mm diameter glass hole for proper installation.

2. Setup and Installation

The WKG150 kit is designed for secure installation on glass panels. Careful attention to glass thickness and hole dimensions is crucial for proper fit and function.

  1. Prepare Glass Panel: Ensure the glass panel has a circular opening with a diameter of 172 mm. The glass thickness must be between 2 mm and 35 mm.
  2. Position the Kit: Insert the WKG150 kit into the prepared glass opening. Ensure the external grille faces outwards.
  3. Secure the Kit: Follow the specific instructions provided with your Aerauliqa QD-QS-QA 150 vacuum cleaner for securing the kit to the glass and connecting it to the vacuum unit. Ensure all connections are tight and sealed to prevent air leaks.
Diagram showing dimensions for WKG100, WKG120, and WKG150 models, including overall width (A), depth (B), and glass hole diameter.
Figure 1: Dimensional diagram for the WKG150 kit. For the WKG150 model, dimension A (overall width) is 218 mm, dimension B (depth) is 117 mm, and the required glass hole diameter is 172 mm. All dimensions are in millimeters. This diagram is essential for accurate installation planning.

3. Operating Instructions

The WKG150 Glass Application Kit is a passive component designed to integrate your Aerauliqa QD-QS-QA 150 series vacuum cleaner with a glass panel. It does not require separate operation.

  • Once correctly installed, the kit functions as a fixed external grille, facilitating the intake or exhaust of air for the connected vacuum cleaner.
  • The operation of the airflow system is controlled entirely by the connected Aerauliqa QD-QS-QA 150 vacuum cleaner unit.
  • Ensure the grille remains unobstructed to allow for optimal airflow.

4. Maintenance

Regular maintenance of the WKG150 kit ensures its longevity and optimal performance.

  • Cleaning: Periodically clean the external grille to remove accumulated dust, dirt, or debris. Use a soft cloth dampened with mild soap and water.
  • Avoid Harsh Chemicals: Do not use abrasive cleaners, solvents, or strong chemical agents, as these can damage the ABS material and its finish.
  • Inspection: Occasionally inspect the kit for any signs of damage or loose connections. Address any issues promptly to maintain system integrity.

5. Troubleshooting

If you encounter issues with the WKG150 kit, consider the following troubleshooting steps:

  • Reduced Airflow: If the vacuum cleaner's airflow seems reduced, check the external grille for any obstructions (e.g., leaves, debris). Ensure the grille is clean.
  • Unusual Noise: Verify that the kit is securely mounted to the glass panel and that all connections to the vacuum cleaner are tight. Loose components can cause vibrations and noise.
  • Improper Fit: Re-check the glass hole dimensions (172 mm diameter) and glass thickness compatibility (2-35 mm) if the kit does not fit properly or appears loose.
  • Material Damage: While the ABS material is shock and UV resistant, extreme conditions can cause damage. Inspect for cracks or discoloration. If damage is significant, replacement may be necessary.

6. Specifications

SpecificationDetail
ManufacturerAERAULIQA
Part NumberPKV00005
Item Model NumberPKV00005
Item Weight1.63 pounds (0.74 kg)
Product Dimensions8.27 x 8.27 x 4.61 inches (210 x 210 x 117 mm)
ColorBianco Ral 9010
MaterialABS (Acrylonitrile Butadiene Styrene)
Glass Thickness Compatibility2 to 35 mm
Required Glass Hole Diameter172 mm
Performance graph for WKG150 showing static pressure in Pascals versus airflow in cubic meters per hour.
Figure 2: Performance curve for the WKG150 kit. This graph illustrates the relationship between static pressure (Pa) and airflow (m³/h), indicating the kit's aerodynamic characteristics and efficiency under various operating conditions.

7. Warranty and Support

For detailed warranty information, terms, and conditions, please refer to the official AERAULIQA website or contact your authorized dealer. It is recommended to retain your purchase receipt as proof of purchase for any warranty claims.

For technical assistance, product inquiries, or support, please reach out to AERAULIQA customer service or your local distributor. Contact information can typically be found on the manufacturer's official website.

Related Documents - PKV00005

Preview Aerauliqa Quantum NEXT: Manuale di Installazione, Uso e Manutenzione
Manuale completo per l'installazione, l'uso e la manutenzione dell'unità di ventilazione Aerauliqa Quantum NEXT con recupero di calore. Scopri le caratteristiche tecniche, le precauzioni di sicurezza e le istruzioni operative.
Preview Aerauliqa PULSAR 100/150 Installation, Use, and Maintenance Manual
This manual provides comprehensive instructions for the installation, operation, and maintenance of the Aerauliqa PULSAR 100 and PULSAR 150 residential heat recovery ventilation units. It covers safety precautions, technical specifications, functional descriptions, troubleshooting, and disposal information.
Preview Aerauliqa PULSAR Residential Heat Recovery Ventilation Unit - Installation, Use, and Maintenance Manual
This comprehensive manual provides detailed instructions for the installation, operation, maintenance, and troubleshooting of the Aerauliqa PULSAR residential heat recovery ventilation unit. It covers technical specifications, configuration options, and safety precautions for optimal performance and energy efficiency.
Preview Aerauliqa Quantum NEXT: Manuale di Installazione e Uso
Manuale completo per l'installazione, l'uso e la manutenzione dell'unità di ventilazione Aerauliqa Quantum NEXT con recupero di calore. Scopri le caratteristiche tecniche, il funzionamento e le precauzioni.
Preview Aerauliqa ORION: Manuale di Installazione, Uso e Manutenzione
Scopri il manuale completo per l'unità di ventilazione Aerauliqa ORION. Guida dettagliata all'installazione, all'uso e alla manutenzione per un ambiente domestico salubre ed efficiente.
Preview Aerauliqa ORION Heat Recovery Ventilation Unit: Installation, Use, and Maintenance Manual
Comprehensive guide for the Aerauliqa ORION residential decentralized heat recovery ventilation unit. Covers installation, operation, maintenance, troubleshooting, and technical specifications for models ORION 100 and ORION 150.