Introduction
This manual provides detailed instructions for the installation, operation, and maintenance of the Norlake 154014 Digital Control, designed for Dixell XC10CX-5P00G units operating at 230V. Please read this manual thoroughly before installation and use to ensure proper function and safety.
Safety Information
Always follow basic safety precautions when installing, operating, or maintaining this device. Failure to do so may result in personal injury or damage to the equipment.
- Ensure the power supply is disconnected before any installation or maintenance procedures.
- This device operates at 230V. Only qualified personnel should perform electrical connections.
- Do not expose the control unit to excessive moisture or extreme temperatures outside its specified operating range.
- Verify all connections are secure and correct before applying power.
What's in the Box
The package for your Norlake 154014 Digital Control should contain the following item:
- 1 x Norlake 154014 Digital Control (Replacement Part)
Installation and Setup
The Norlake 154014 Digital Control is designed for integration into compatible refrigeration systems, specifically Dixell XC10CX-5P00G models. Proper installation is crucial for optimal performance.
Mounting the Control Unit
The unit is typically panel-mounted. Ensure adequate space for ventilation and access to wiring terminals.
Electrical Connections
Refer to the wiring diagram printed on the top of the control unit for correct electrical connections. The unit requires a 230V power supply.

Image: Norlake 154014 Digital Control Unit. This image displays the front face of the digital control unit, featuring a digital display, control buttons (up, down, set, start, manual/wrench icon, and a book/exclamation mark icon), and the "Dixell XC" branding. The top of the unit shows terminal connections and voltage ratings (230V).
Key Connection Points:
- Line (L): Main power input.
- Supply (230V~ 50-60Hz): Power input terminals (e.g., terminals 4 and 5).
- Compressor (Comp): Output for compressor control.
- 16(5)A 250V~: Maximum current and voltage rating for certain outputs.
- Sensor Inputs: Terminals for temperature probes (e.g., 10, 11, 12 for NTC sensors).
- Digital Inputs: Terminals for external switches or signals (e.g., 13, 14, 15, 16, 17).
Ensure all wiring complies with local electrical codes and standards.
Operating Instructions
The Dixell XC10CX-5P00G digital control provides precise temperature management and system monitoring.
Basic Operation
- Power On: Once correctly wired, apply power to the unit. The digital display will illuminate.
- Temperature Display: The main display typically shows the current temperature of the controlled environment.
- SET Button: Press the SET button to view or modify the setpoint temperature. Use the Up and Down arrows to adjust the value. Press SET again to confirm.
- Up/Down Arrows: Used for navigating menus and adjusting values.
- Start/Stop Button: The button with the circular arrow and "Start" text is typically used to manually start or stop a defrost cycle or other specific functions.
- Manual/Wrench Button: The button with the wrench and clock icon may access advanced settings or manual control functions.
- Information/Alarm Button: The button with the book and exclamation mark icon is often used to view alarms or access information about the unit's status.
Advanced Settings
Accessing advanced parameters usually involves holding the SET button for several seconds or a combination of buttons. Refer to the comprehensive Dixell XC10CX-5P00G manual for detailed parameter descriptions and adjustment procedures. Incorrect parameter settings can lead to system malfunction.
Maintenance
Regular maintenance ensures the longevity and reliable operation of your digital control unit.
- Cleaning: Periodically clean the front panel with a soft, damp cloth. Do not use abrasive cleaners or solvents.
- Connections: Annually check all electrical connections for tightness and signs of corrosion.
- Sensor Integrity: Ensure temperature sensors are clean and properly positioned.
- Software Updates: Consult Norlake or Dixell for information on any available firmware updates.
Always disconnect power before performing any maintenance.
Troubleshooting
This section provides solutions to common issues you might encounter with the Norlake 154014 Digital Control.
| Problem | Possible Cause | Solution |
|---|---|---|
| Display is blank | No power supply; Loose wiring; Blown fuse. | Check power connection; Verify wiring; Replace fuse if necessary. |
| Incorrect temperature reading | Faulty sensor; Sensor not properly connected or positioned. | Check sensor wiring; Reposition sensor; Replace sensor if damaged. |
| Unit not responding to button presses | Keypad malfunction; Unit frozen. | Power cycle the unit; Contact technical support if issue persists. |
| System not cooling/heating as expected | Incorrect setpoint; Parameter misconfiguration; External system issue. | Verify setpoint; Review advanced parameters; Check compressor/fan operation. |
For issues not listed here, or if troubleshooting steps do not resolve the problem, please contact Norlake technical support.
Specifications
- Model Number: 154014
- Product Type: Digital Control for Dixell XC10CX-5P00G
- Voltage: 230V
- Frequency: 50-60Hz
- Dimensions (Product): Approximately 9.0" (L) x 6.0" (W) x 5.0" (H) (based on package dimensions)
- Weight (Product): Approximately 8.48 ounces
- Country of Origin: Italy
- Manufacturer: Norlake
- ASIN: B07VQJW5QV
Warranty and Support
For warranty information and technical support regarding your Norlake 154014 Digital Control, please refer to the documentation provided with your original purchase or contact Norlake directly. Keep your purchase receipt and model number handy when contacting support.
Norlake Contact Information: Please visit the official Norlake website or refer to your product packaging for the most current contact details.