Olimpia Splendid Aquaria Slim 12 P (01957)

Olimpia Splendid Aquaria Slim 12 P Dehumidifier User Manual

Model: 01957

1. Introduction

This manual provides essential information for the safe and efficient operation of your Olimpia Splendid Aquaria Slim 12 P Dehumidifier. Please read it thoroughly before use and retain it for future reference.

The Aquaria Slim 12 P is designed to remove excess moisture from the air, improving indoor air quality and preventing issues like mold and mildew. It features a compact design, a Pure System filter, and a 12-liter per day dehumidification capacity.

Olimpia Splendid Aquaria Slim 12 P Dehumidifier front view

Image 1.1: Front view of the Olimpia Splendid Aquaria Slim 12 P Dehumidifier.

Key Features:

  • Dehumidification Capacity: Up to 12 liters per day.
  • Programmable Timer: 1 to 24-hour operation.
  • Compact and Portable: Slim design (19 cm thickness) with a rear handle and pivoting wheels for easy transport.
  • Pure System: Integrated dust filter and activated carbon filter for improved air quality.
  • Water Drainage Options: Continuous condensate discharge or removable 2.5-liter tank.
  • Automatic Shut-off: Activates when the water tank is full.
  • Eco-friendly Refrigerant: Pre-charged with natural R290 gas, ensuring minimal global warming impact.

2. Safety Information

Please observe the following safety precautions to prevent injury and damage to the unit.

  • Always connect the unit to a grounded power outlet.
  • Do not operate the dehumidifier with a damaged power cord or plug.
  • Keep the unit away from water and other liquids. Do not immerse it.
  • Ensure proper ventilation around the unit. Do not block air inlets or outlets.
  • Do not insert objects into the unit's openings.
  • Unplug the unit before cleaning or performing any maintenance.
  • This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
  • The appliance contains R290 refrigerant. Do not puncture the refrigerant circuit.

3. Setup

3.1 Unpacking

  1. Carefully remove the dehumidifier from its packaging.
  2. Remove all packing materials, including any tape or protective films.
  3. Inspect the unit for any signs of damage. If damaged, do not operate and contact customer support.

3.2 Placement

Choose a suitable location for your dehumidifier. For optimal performance, consider the following:

  • Place the unit on a flat, stable surface.
  • Ensure there is at least 20 cm (8 inches) of space around the air inlets and outlets for proper airflow.
  • Avoid placing the unit near heat sources or in direct sunlight.
  • For best results, close all doors and windows in the room where the dehumidifier is operating.
Dehumidifier placed in a laundry room

Image 3.1: The dehumidifier is suitable for use in various residential settings, such as a laundry room.

3.3 Power Connection

Plug the power cord into a standard, grounded electrical outlet. The unit is now ready for operation.

Bottom view of dehumidifier showing wheels

Image 3.2: The unit features pivoting wheels for easy movement and positioning.

4. Operating Instructions

The control panel allows you to manage all functions of the dehumidifier.

Control panel of the Olimpia Splendid Aquaria Slim 12 P Dehumidifier

Image 4.1: Overview of the control panel with various buttons and digital display.

4.1 Control Panel Functions

  • ON/OFF Button: Press to turn the unit on or off.
  • TIMER Button: Press to set the operating timer (1-24 hours).
  • '+' and '-' Buttons: Adjust humidity levels or timer settings.
  • FAN Button: Select fan speed (if applicable).
  • LAUNDRY Mode: Activates continuous dehumidification for drying clothes.
  • Digital Display: Shows current humidity level or temperature.
  • FULL Indicator: Illuminates when the water tank is full.

4.2 Setting Desired Humidity

  1. Turn on the dehumidifier using the ON/OFF button.
  2. Use the '+' or '-' buttons to set your desired humidity level. The display will show the target humidity.
  3. The unit will operate until the desired humidity is reached, then cycle on and off to maintain it.

4.3 Continuous Drainage

For continuous operation without emptying the water tank, connect a drainage hose (not included) to the continuous drainage outlet on the back of the unit. Ensure the hose is sloped downwards to allow gravity drainage into a suitable receptacle.

5. Maintenance

Regular maintenance ensures optimal performance and longevity of your dehumidifier.

5.1 Emptying the Water Tank

When the 'FULL' indicator light illuminates, the water tank needs to be emptied. The unit will automatically stop operating.

  1. Gently pull out the water tank from the side of the unit.
  2. Empty the collected water.
  3. Slide the empty tank back into its position until it clicks securely. The unit will resume operation.
Removing the water tank from the dehumidifier

Image 5.1: The removable 2.5-liter water tank with integrated handle for easy extraction and transport.

5.2 Cleaning the Air Filter

The Pure System filter should be cleaned regularly (every 2-4 weeks, depending on usage) to maintain air quality and unit efficiency.

  1. Turn off and unplug the dehumidifier.
  2. Locate and remove the air filter (refer to the diagram in your physical manual for exact location).
  3. Clean the filter using a vacuum cleaner or wash it gently with lukewarm water and mild detergent.
  4. Allow the filter to air dry completely before reinserting it.

5.3 Cleaning the Unit Exterior

Wipe the exterior of the unit with a soft, damp cloth. Do not use abrasive cleaners or solvents.

6. Troubleshooting

If you encounter issues with your dehumidifier, consult the following table before contacting customer support.

ProblemPossible CauseSolution
Unit does not turn on.No power supply. Power cord not plugged in.Check power connection. Ensure outlet is functional.
Dehumidifier not collecting water.Humidity setting too high. Room temperature too low. Air filter clogged.Lower the desired humidity setting. Ensure room temperature is above 5°C (41°F). Clean the air filter.
'FULL' indicator is on, but tank is not full.Water tank not properly seated.Remove and reinsert the water tank, ensuring it clicks into place.
Unit is noisy.Unit not on a level surface. Air filter clogged.Place the unit on a flat, stable surface. Clean the air filter.

7. Specifications

Detailed technical specifications for the Olimpia Splendid Aquaria Slim 12 P Dehumidifier.

Dimensions of the Olimpia Splendid Aquaria Slim 12 P Dehumidifier

Image 7.1: Product dimensions: 49 cm height, 32 cm width, 18.5 cm depth.

  • Model Name: Olimpia Splendid 01957 Aquaria Slim 12 P Dehumidifier
  • Model Number: 01957
  • Brand: Olimpia Splendid
  • Dehumidification Capacity: 12 Liters per day
  • Water Tank Volume: 2.5 Liters (removable)
  • Recommended Room Area: Up to 55 m³ (approx. 4 square meters floor area)
  • Dimensions (Depth x Width x Height): 18.5 cm x 32 cm x 49 cm
  • Weight: 10.5 Kilograms
  • Refrigerant: R290 (Natural Gas)
  • Special Features: Pure System (Dust and Activated Carbon Filter), Timer (1-24h), Automatic Shut-off (full tank), Laundry Function.
  • Operation: Automatic
  • Number of Speeds: 1
  • Recommended Use: Residential
  • Material: Plastic and Metal
  • Color: White

8. Warranty & Support

8.1 Warranty Information

Your Olimpia Splendid Aquaria Slim 12 P Dehumidifier is covered by a manufacturer's warranty. Please refer to the warranty card included with your purchase for specific terms, conditions, and duration. Keep your proof of purchase for warranty claims.

8.2 Customer Support

For technical assistance, spare parts, or warranty service, please contact Olimpia Splendid customer support. Contact details can typically be found on the manufacturer's official website or in the documentation provided with your product.

© 2026 Olimpia Splendid. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.