Tektronix MSO44 4-BW-200

Tektronix MSO44 4-BW-200 Mixed Signal Oscilloscope User Manual

Model: MSO44 4-BW-200

1. Introduction

This user manual provides comprehensive instructions for the operation, maintenance, and troubleshooting of the Tektronix MSO44 4-BW-200 Mixed Signal Oscilloscope. This advanced instrument is designed for precise signal analysis, offering high resolution and versatile measurement capabilities for various applications, including embedded systems, power electronics, and automotive electronics.

Tektronix MSO44 4-BW-200 Mixed Signal Oscilloscope

Figure 1: Front view of the Tektronix MSO44 4-BW-200 Mixed Signal Oscilloscope, showcasing its large touchscreen display, multiple input channels, and control knobs. The device features a blue handle for portability.

2. Setup and Initial Configuration

2.1 Unpacking and Inspection

Carefully remove the oscilloscope from its packaging. Inspect the unit for any signs of physical damage that may have occurred during transit. Retain the original packaging for future transportation or storage.

2.2 Power Connection

  1. Ensure the oscilloscope's power switch is in the OFF position.
  2. Connect the provided power cord to the AC input on the rear panel of the oscilloscope.
  3. Plug the other end of the power cord into a grounded AC power outlet.

2.3 Initial Power On

Press the power button located on the front panel. The oscilloscope will perform a self-test and boot up. The display will show the Tektronix logo followed by the main measurement interface.

2.4 Connecting Probes and Inputs

The MSO44 features FlexChannels, which can be configured as analog or digital inputs.

3. Operating Instructions

3.1 User Interface Overview

The oscilloscope features a 13.3-inch HD capacitive touchscreen display for intuitive operation. Key controls are also available via physical knobs and buttons on the right side of the display.

3.2 Basic Measurements

  1. Channel Setup: Press the channel button corresponding to the input you wish to configure. Use the touchscreen or vertical scale knob to adjust vertical sensitivity (Volts/Div).
  2. Time Base: Use the horizontal scale knob to adjust the time base (Seconds/Div) to view the desired number of cycles.
  3. Triggering: The trigger system stabilizes repetitive waveforms. Use the trigger level knob to set the trigger threshold. Select trigger type (Edge, Pulse, Runt, etc.) from the trigger menu on the screen.
  4. Measurements: Access the 'Measure' menu to add automatic measurements such as frequency, peak-to-peak voltage, RMS, etc.

3.3 Advanced Features

4. Maintenance

4.1 Cleaning the Instrument

To maintain the performance and appearance of your oscilloscope:

4.2 Calibration

The MSO44 is factory calibrated. For optimal performance, periodic calibration by a qualified service center is recommended. Refer to the Tektronix website or contact support for calibration services.

4.3 Storage

When not in use for extended periods, store the oscilloscope in a clean, dry environment, away from direct sunlight and extreme temperatures. Use the original packaging or a suitable protective case.

5. Troubleshooting

ProblemPossible CauseSolution
No display after power onPower cord not connected; Power outlet issue; Internal faultCheck power cord connection; Verify power outlet functionality; Contact Tektronix support
No waveform displayedProbe not connected; Incorrect channel settings; Trigger not set correctly; Signal too small or largeEnsure probe is connected and functional; Check channel voltage/division settings; Adjust trigger level and type; Adjust vertical scale or input signal
Unstable waveformImproper trigger settings; Noise in signal; Grounding issueAdjust trigger source, level, and slope; Use averaging or bandwidth limit; Ensure proper grounding of the oscilloscope and circuit
Touchscreen unresponsiveTemporary software glitch; Screen calibration neededRestart the oscilloscope; Refer to the full manual for touchscreen calibration procedures

6. Specifications

The following table outlines the key technical specifications for the Tektronix MSO44 4-BW-200 Mixed Signal Oscilloscope.

FeatureSpecification
Number of FlexChannels4
Bandwidth (all analog channels)200 MHz
Sample Rate (all analog/digital channels)6.25 GS/s (real-time)
Vertical Resolution12 bits ADC (16 bits in High Resolution Mode)
Display13.3 in. color HD (1920 x 1080) capacitive touchscreen
Record Length31.25 M points
Product Dimensions2.76 x 0.79 x 10.24 inches
Item Weight48.75 Pounds

7. Warranty and Support

7.1 Warranty Information

Tektronix products are backed by a standard warranty. For detailed information regarding the warranty period and terms for your MSO44 4-BW-200 oscilloscope, please refer to the warranty card included with your product or visit the official Tektronix website.

7.2 Technical Support

Should you encounter any issues or require technical assistance, please contact Tektronix customer support.

Related Documents - MSO44 4-BW-200

Preview Tektronix 4 Series MSO Oscilloscope Specifications and Performance Verification
Comprehensive technical specifications and performance verification procedures for Tektronix 4 Series Mixed Signal Oscilloscopes (MSO), including models MSO44, MSO46, MSO44B, and MSO46B. This document details instrument capabilities and testing methods.
Preview Tektronix 4 Series MSO Oscilloscope: Specifications and Performance Verification
Detailed specifications and performance verification procedures for the Tektronix 4 Series MSO oscilloscopes, including models MSO44, MSO46, MSO44B, and MSO46B. Covers electrical, timing, trigger, and measurement capabilities.
Preview Tektronix 4 Series Mixed Signal Oscilloscopes Declassification and Security Instructions
Instructions for declassifying and sanitizing Tektronix 4 Series Mixed Signal Oscilloscopes (MSO44, MSO46) to ensure data security, covering procedures for working and non-functional instruments.
Preview Tektronix 4/5/6 Series MSO Printable Help: User Guide
Comprehensive user manual for Tektronix 4/5/6 Series Mixed Signal Oscilloscopes (MSO44, MSO46, MSO54, MSO56, MSO58, MSO58LP, MSO64), detailing features, installation, operation, and interface.
Preview Tektronix 3 Series MDO Mixed Domain Oscilloscope: Printable Help Guide
Comprehensive printable help guide for the Tektronix 3 Series MDO Mixed Domain Oscilloscope (MDO32, MDO34), covering installation, operation, features, and troubleshooting.
Preview Tektronix 6 Series B MSO Service Manual: MS064B, MS066B, MSO68B
Detailed service manual for Tektronix 6 Series B Mixed Signal Oscilloscopes (MS064B, MS066B, MSO68B), covering theory of operation, maintenance, troubleshooting, and replaceable parts.