1. Introduction

This manual provides instructions for the safe and effective operation of your AOPUTTRIVER AP-816B Portable Digital Anemometer. This device is designed for precise measurement of wind speed, temperature, and wind chill, offering various units and modes for diverse applications. Its compact and lightweight design makes it ideal for both professional and recreational use.

AOPUTTRIVER AP-816B Portable Digital Anemometer

Image 1: AOPUTTRIVER AP-816B Portable Digital Anemometer

2. Package Contents

Please check the package contents to ensure all items are present:

  • AP-816B Handheld Anemometer
  • 3V (CR2032) Battery
  • Lanyard
  • User Manual

3. Key Features

The AP-816B Anemometer offers a range of features for comprehensive wind and temperature measurement:

  • High-precision measurement of wind speed (0.3 to 30 m/s with ±5% accuracy) and temperature (-10°C to 45°C with ±2°C accuracy).
  • Multifunctional display including wind chill indication.
  • Backlit LCD screen for easy reading in low-light conditions.
  • Versatile applications for outdoor activities (shooting, sailing, mountaineering) and electrical equipment testing (HVAC).
  • Compact and lightweight design for portability.
  • Automatic and manual power-off options.
  • Selectable wind speed units: m/s, ft/min, knots, km/h, mph.
  • Temperature units: Celsius (°C) and Fahrenheit (°F).
  • Low battery indicator.
Features of AOPUTTRIVER AP-816B Anemometer showing fan, sensor, LCD display, and control buttons

Image 2: Key components and display of the AP-816B

4. Setup Guide

4.1 Battery Installation

The AP-816B anemometer uses one CR2032 3V battery. Follow these steps to install or replace the battery:

  1. Locate the battery cover on the back of the device.
  2. Use a coin or a Phillips screwdriver to rotate the battery cover counter-clockwise to open.
  3. Insert the CR2032 battery with the positive (+) side facing up.
  4. Replace the battery cover and rotate clockwise to secure.
Steps for battery replacement in AOPUTTRIVER AP-816B Anemometer

Image 3: Battery replacement procedure

5. Operating Instructions

5.1 Power On/Off

Press the MODE button to turn the device on. The device features an auto-off function to conserve battery power. To manually turn off the device, press and hold the MODE button for a few seconds.

5.2 Measurement Modes

The AP-816B can display wind speed in Current, Average, and Maximum modes:

  • Current Speed: Displays the real-time wind speed.
  • Average Speed (AVG): Displays the average wind speed over a period.
  • Maximum Speed (MAX): Displays the highest wind speed recorded since power-on.

Press the MODE button repeatedly to cycle through these measurement modes.

5.3 Unit Selection

The device supports multiple wind speed units (m/s, ft/min, knots, km/h, mph) and temperature units (°C/°F).

  • To change the wind speed unit, press the SET button. Each press will cycle through the available units.
  • To switch between Celsius (°C) and Fahrenheit (°F) for temperature, press the °C/°F button.
AOPUTTRIVER AP-816B Anemometer display showing wind speed and temperature readings with control buttons

Image 4: Anemometer display and button functions

5.4 Backlight Function

The LCD display features a backlight for improved visibility in low-light conditions. The backlight activates automatically when the device is in use.

6. Care and Maintenance

6.1 Cleaning

Wipe the device with a soft, dry cloth. Do not use abrasive cleaners or solvents. Ensure the fan blades are free from dust and debris for accurate readings.

6.2 Storage

When not in use for extended periods, remove the battery to prevent leakage. Store the anemometer in a cool, dry place, away from direct sunlight and extreme temperatures.

7. Troubleshooting Guide

If you encounter any issues with your AP-816B Anemometer, please refer to the table below for common problems and solutions:

ProblemPossible CauseSolution
Device does not power onLow or dead batteryReplace the CR2032 battery.
Inaccurate wind speed readingsObstruction in fan bladesClean the fan blades.
Device not held correctlyEnsure the device is held upright and facing the wind.
Display is dim or blankLow batteryReplace the CR2032 battery.
Unit conversion issuesIncorrect unit selectedPress the SET button to cycle through wind speed units or °C/°F button for temperature units.

8. Product Specifications

Detailed technical specifications for the AOPUTTRIVER AP-816B Anemometer:

ParameterValue
BrandAOPUTTRIVER
ModelUK-AP-816B
Wind Speed Range0.3 - 30 m/s
Wind Speed Accuracy±5% of reading
Temperature Range-10°C to 45°C (14°F to 113°F)
Temperature Accuracy±2°C
Resolution0.1 m/s (wind speed), 0.2°C (temperature)
DisplayLCD with Backlight
Battery Type1 x CR2032 3V
Auto Power OffYes
Dimensions (L x W x H)11.3 x 4 x 1.5 cm
Weight70 Grams (with battery)
AOPUTTRIVER AP-816B Anemometer dimensions and detailed specifications table

Image 5: Dimensions and detailed specifications

9. Warranty and Customer Support

This AOPUTTRIVER product comes with a 2-year warranty and lifetime technical support, ensuring long-term reliability and assistance.

For any issues, technical inquiries, or warranty claims, please do not hesitate to contact AOPUTTRIVER customer service. Refer to the product packaging or the official AOPUTTRIVER website for the most current contact details.

Related Documents - UK-AP-816B

Preview 7200APP DC/AC True-RMS Digital Clamp Multimeter User Manual
User manual for the AOPUTTRIVER 7200APP DC/AC True-RMS Digital Clamp Multimeter. This auto-ranging, 6000-count meter measures amperage, voltage, capacitance, continuity, and resistance, featuring Bluetooth connectivity via the AILink app. Includes safety, operation, and maintenance details.
Preview 6000 Counts True-RMS Auto Range Intelligent Digital AC/DC Clamp Multimeter Operation Manual
This document provides the operation manual for the AOPUTTRIVER 6000 Counts True-RMS Auto Range Intelligent Digital AC/DC Clamp Multimeter (Model AP-570S-APP), detailing its features, specifications, operating instructions, and companion AiLink mobile application.
Preview AOPUTTRIVER AR8500 Ammonia Gas Detector User Manual and Technical Specifications
Comprehensive instruction manual for the AOPUTTRIVER AR8500 Ammonia Gas Detector. Covers product description, technical parameters, operation, maintenance, and safety precautions for this precision measurement apparatus.
Preview Quick Start Guide - AOPUTTRIVER Infrared Thermometer AP-2732
Get started quickly with your AOPUTTRIVER Infrared Thermometer (AP-2732). This guide covers battery installation, basic operation, and understanding the display readings for models like the AP-2732.
Preview AOPUTTRIVER AP-570C-APP Bluetooth Connection Guide
Step-by-step instructions for connecting the AOPUTTRIVER AP-570C-APP clamp meter to your smartphone via Bluetooth. Includes troubleshooting tips for a seamless setup.
Preview Victor Digital Anemometer Instruction Manual
Instruction manual for the Victor Digital Anemometer, detailing its functions, LCD display, operation, and specifications. Covers air velocity and temperature measurements, data hold, unit selection, and power management.