Kamoer KCP PRO2

Kamoer KCP PRO2 Peristaltic Dosing Pump Instruction Manual

Model: KCP PRO2

Introduction

This manual provides essential information for the safe and efficient operation of your Kamoer KCP PRO2 High Flow Peristaltic Dosing Pump. Please read these instructions carefully before use and retain them for future reference.

The Kamoer KCP PRO2 is a variable speed 12V DC peristaltic pump designed for precise fluid transfer in laboratory, chemical, and industrial applications. It features an adjustable flow rate from 40 to 210 ml/min.

Safety Information

  • Ensure the power supply matches the pump's voltage requirements (12V DC).
  • Do not operate the pump with damaged tubing or power cords.
  • Avoid immersing the pump in liquid.
  • Always disconnect power before performing maintenance or changing tubing.
  • This pump is designed for intermittent applications. Continuous use may reduce tubing lifespan.

Package Contents

Verify that all items are present in the package:

  • Kamoer KCP PRO2 Peristaltic Dosing Pump
  • 12V DC Power Adapter
  • Norprene Tube (pre-installed or included)
Kamoer KCP PRO2 pump with power adapter

Figure 1: Kamoer KCP PRO2 pump with its included power adapter.

Specifications

FeatureValue
Voltage12V DC
Flow Rate40-210 ml/min
Weight765g (with power supply)
Positive Pressure0.15 Mpa
Negative Pressure-0.09 Mpa
Dimensions (L x W x H)110mm x 76mm x 140mm (approx. 4.33"L x 3.0"W x 5.5"H)
MaterialStainless Steel (housing)
Technical drawing showing Kamoer KCP PRO2 pump dimensions

Figure 2: Dimensional drawing of the KCP PRO2 pump.

Setup

  1. Placement: Position the pump on a stable, level surface. Ensure adequate ventilation around the unit.
  2. Tubing Connection: Connect the inlet and outlet tubing to the peristaltic pump head. Ensure connections are secure to prevent leaks. The pump is designed for easy, tool-free tubing changes.
  3. Power Connection: Connect the 12V DC power adapter to the pump's power input port. Then, plug the power adapter into a suitable electrical outlet.
Kamoer KCP PRO2 pump with tubing connected

Figure 3: KCP PRO2 pump with tubing installed, ready for operation.

Operating Instructions

  1. Power On: Once connected to power, the pump is ready for operation.
  2. Adjust Flow Rate: Use the "MIN" to "MAX" speed knob on the front panel to adjust the flow rate. Turning the knob towards "MAX" increases the flow rate, up to 210 ml/min. Turning it towards "MIN" decreases the flow rate, down to 40 ml/min.
  3. Control Direction: Use the L/R switch to select the pumping direction:
    • L (Left): Counter-clockwise rotation.
    • R (Right): Clockwise rotation.
    • Center: Stops the pump.
  4. Monitoring: Observe the fluid transfer to ensure the desired flow and direction are achieved. The LED indicator may show operational status.
Close-up of Kamoer KCP PRO2 control panel showing speed knob and direction switch

Figure 4: Front panel controls for flow rate and direction.

Video 1: Demonstration of KCP PRO2 pump operation, showing fluid transfer and control adjustments.

Maintenance

  • Tubing Replacement: The peristaltic tubing is a wear component and will require periodic replacement depending on usage and the type of fluid being pumped. Inspect the tubing regularly for signs of wear, cracks, or degradation. Replace tubing promptly to maintain optimal performance and prevent leaks.
  • Cleaning: Wipe the exterior of the pump with a soft, damp cloth. Do not use abrasive cleaners or solvents. Ensure no liquid enters the pump's internal components.
  • Storage: When not in use for extended periods, disconnect the power adapter and store the pump in a clean, dry environment.

Troubleshooting

ProblemPossible CauseSolution
Pump does not startNo power, faulty power adapter, or switch in center position.Check power connection and outlet. Ensure power adapter is functional. Verify L/R switch is engaged.
Uneven or inconsistent flowWorn tubing, air bubbles in tubing, or fluid viscosity too high.Inspect and replace tubing if worn. Prime the pump to remove air. Ensure fluid is compatible with pump specifications.
Leakage from pump headDamaged or improperly installed tubing.Check tubing for damage and ensure it is correctly seated in the pump head. Replace if necessary.
Reduced flow rateWorn tubing, blockage, or incorrect speed setting.Replace worn tubing. Check for and clear any blockages in the tubing or pump head. Adjust speed knob to a higher setting.

Warranty Information

Specific warranty details for the Kamoer KCP PRO2 Peristaltic Dosing Pump are not provided in this document. For warranty terms and conditions, please refer to the product packaging or contact Kamoer customer support directly.

Customer Support

For technical assistance, troubleshooting, or inquiries regarding your Kamoer KCP PRO2 pump, please contact Kamoer Fluid Tech (Shanghai) Co., Ltd. customer support.

  • Manufacturer: Kamoer Fluid Tech (Shanghai) Co., Ltd.
  • Email: daijing@kamoer.com
  • Website: Refer to the official Kamoer website for additional resources and contact options.

© 2024 Kamoer Fluid Tech (Shanghai) Co., Ltd. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.