Youmile TS-YM-303

Youmile MOS FET Trigger Switch Drive Module TS-YM-303 Instruction Manual

1. Introduction

This manual provides detailed instructions for the Youmile MOS FET Trigger Switch Drive Module (Model: TS-YM-303). This module is designed for controlling high-power equipment using a low-power trigger signal, supporting Pulse Width Modulation (PWM) for various applications.

2. Product Features

3. Setup and Wiring

Proper wiring is essential for the safe and correct operation of the module. Refer to the diagram below for connection details.

Wiring diagram for Youmile MOS FET Trigger Switch Drive Module showing input signal, GND, load, and DC power supply connections.
Figure 3.1: Wiring Diagram. This image illustrates the connection points for the input signal (PWM+), ground (GND), load (OUT+ and OUT-), and DC power supply (DC+ and DC-). The module features two MOS transistors for driving the load and an LED for switching indication.

3.1. Connection Points

3.2. Wiring Procedure

  1. Ensure all power sources are disconnected before wiring.
  2. Connect the main DC power supply (5V-36V) to the VIN+ and VIN- terminals. Observe polarity.
  3. Connect your load (e.g., motor, LED) to the OUT+ and OUT- terminals. Ensure the load's operating voltage is within the module's output range.
  4. Connect your control signal source (e.g., microcontroller, PLC) to the TRIG / PWM terminal.
  5. Connect the ground of your control signal source to the GND terminal on the module.
  6. Double-check all connections for correct polarity and secure fastening.

4. Operating Instructions

The module operates by switching the connected load based on the input trigger signal. For applications requiring variable control, a PWM signal can be used.

4.1. Basic On/Off Control

To simply turn the load on or off, apply a digital high (3.3V - 20V) signal to the TRIG / PWM terminal for 'ON' and a digital low (0V) or disconnect for 'OFF'. The onboard LED will indicate the switching status.

4.2. PWM Control

For applications like motor speed control or LED brightness adjustment, apply a PWM signal to the TRIG / PWM terminal. The module will modulate the power to the load according to the duty cycle of the PWM signal. The supported PWM frequency range is 0-20 kHz.

5. Specifications

ParameterValue
Model NumberTS-YM-303
Operating VoltageDC 5V - 36V
Trigger Source VoltageDC 3.3V - 20V (Digital High/Low)
PWM Frequency Support0 - 20 kHz
Continuous Output Current15A (at ambient temperature)
Maximum Output Current30A (with auxiliary cooling)
Output Power400W
Operating Temperature-40℃ to 85℃
Dimensions (approx.)33.6mm x 17mm (Refer to Figure 5.1)
ManufacturerYoumile
Country of OriginChina
Youmile MOS FET Trigger Switch Drive Module with dimensions 33.6mm by 17mm.
Figure 5.1: Module Dimensions. This image shows the physical dimensions of the Youmile MOS FET Trigger Switch Drive Module, measuring approximately 33.6mm in length and 17mm in width.

6. Maintenance

The Youmile MOS FET Trigger Switch Drive Module is designed for reliable operation with minimal maintenance. Follow these guidelines:

7. Troubleshooting

If you encounter issues with the module, refer to the following troubleshooting steps:

ProblemPossible CauseSolution
Load does not turn ON
  • Incorrect power supply voltage or polarity.
  • No trigger signal or incorrect trigger voltage.
  • Load is faulty or incorrectly wired.
  • Module is damaged.
  • Verify DC power supply (5V-36V) and polarity.
  • Check trigger signal (3.3V-20V for ON) and GND connection.
  • Test the load independently. Recheck load wiring.
  • Replace the module if all other checks fail.
Load does not turn OFF
  • Trigger signal remains high.
  • Module is damaged.
  • Ensure trigger signal goes low (0V) when OFF is desired.
  • Replace the module if the trigger signal is confirmed low.
PWM control is erratic or not working
  • PWM signal frequency is outside 0-20 kHz.
  • PWM signal voltage is incorrect.
  • Poor connection for PWM signal.
  • Verify PWM frequency is within the supported range.
  • Ensure PWM signal voltage is between 3.3V and 20V.
  • Check the integrity of the TRIG / PWM and GND connections.
Module overheats
  • Load current exceeds 15A without auxiliary cooling.
  • Short circuit in the load or wiring.
  • Reduce load current or implement auxiliary cooling (heatsink/fan) for currents above 15A.
  • Inspect load and wiring for any short circuits.

8. Safety Information

Please observe the following safety precautions when working with the module:

9. Warranty and Support

Information regarding specific warranty terms and direct support channels for the Youmile MOS FET Trigger Switch Drive Module TS-YM-303 is not provided in the product details. For any inquiries or support, please refer to the retailer or point of purchase.

Related Documents - TS-YM-303

Preview Youmile ZFC39 V2.0 PWM Fan Controller with Temperature and Alarm Functions
This document provides a comprehensive overview and technical specifications for the Youmile ZFC39 V2.0 PWM fan controller. It details the board's features, connectors, DIP switch configurations for PWM range and temperature control, buzzer alarm settings, and operational examples for PC cooling systems.
Preview Slide Switches: SS12F44 & SK12D07VG3 Specifications and Applications
Detailed specifications, dimensions, and applications for Youmile SS12F44 and SK12D07VG3 slide switches, featuring 1P2T configuration, DC 50V/0.5A ratings, and suitability for electronic projects, model cars, and audio equipment.
Preview Parker LSHT Torqmotors TS Series: Stainless Steel Low Speed, High Torque Hydraulic Motors
Technical overview, specifications, and ordering guide for Parker Hannifin's LSHT Torqmotors TS Series hydraulic motors. Features stainless steel construction for harsh environments, offering high torque at low speeds.
Preview Bedienungsanleitung Tragbarer Inhalator YM-3R* Serie
Diese Bedienungsanleitung für den tragbaren Inhalator der YM-3R* Serie bietet detaillierte Informationen zur sicheren und effektiven Nutzung des Geräts. Sie enthält Anleitungen zur Installation, Verwendung, Reinigung und Wartung, sowie wichtige Sicherheitshinweise und Fehlerbehebungstipps.
Preview Danfoss ICMTS Motor Operated Valve with ICAD 600A-TS Actuator: Installation Guide
This installation guide provides detailed instructions for the Danfoss Motor Operated Valve Type ICMTS with Actuator Type ICAD 600A-TS. It covers refrigerant compatibility, temperature and pressure ratings, technical data, installation procedures, welding and soldering guidelines, manual operation, insulation, surface treatment, assembly, and maintenance. Designed for high-pressure R744 applications, this valve is suitable for various industrial refrigeration systems.
Preview TORK Solenoid Valve User's Manual - Operation, Installation, and Maintenance
Comprehensive user's manual for TORK solenoid valves, covering product overview, coding system, operation, installation, maintenance, spare parts, and warranty information. Includes technical specifications and safety guidelines.