DLYFULL UT2

DLYFULL UT2 USB Multi-Charger Instruction Manual

Model: UT2

1. Introduction

The DLYFULL UT2 is an advanced USB multi-charger designed for various rechargeable battery types, including Li-ion, Ni-MH, AA, AAA, and LiFePO4. It features independent charging slots, an LCD display for real-time information, and multiple operating modes such as Charge, Discharge, Refresh, and Test. This manual provides detailed instructions for safe and efficient use of your DLYFULL UT2 charger.

2. Safety Precautions

  • Use only compatible battery types as specified in this manual. Attempting to charge incompatible batteries may result in damage or injury.
  • Do not disassemble, modify, or attempt to repair the charger. Contact customer support for assistance.
  • Keep the charger away from water, moisture, and high temperatures.
  • Ensure proper ventilation during operation to prevent overheating.
  • Do not leave charging batteries unattended for extended periods.
  • Keep out of reach of children.
  • Always use a suitable USB power adapter (DC 5V/2A recommended) to power the charger.

3. Package Contents

  • DLYFULL UT2 USB Multi-Charger
  • USB Cable (Type-C)
  • Instruction Manual (this document)

4. Product Overview

Familiarize yourself with the components of your DLYFULL UT2 charger.

DLYFULL UT2 USB Multi-Charger front view with LCD display

Figure 4.1: Front View. This image shows the DLYFULL UT2 charger from the front, highlighting the two independent battery slots and the LCD display. The display shows charging status, battery voltage, current, capacity, and mode selection. Buttons for 'MODE' and 'SLOT' are visible below the display.

DLYFULL UT2 USB Multi-Charger side view showing battery slots

Figure 4.2: Side View (Battery Slots). This image provides a side perspective of the charger, clearly showing the two spring-loaded battery contacts within each slot, designed to accommodate various battery sizes.

DLYFULL UT2 USB Multi-Charger side view showing USB output ports

Figure 4.3: Side View (USB Output). This image displays the side of the charger where the USB-A output port and the USB Type-C input port are located. The USB-A port allows the charger to function as a power bank for other devices.

DLYFULL UT2 USB Multi-Charger bottom view with ventilation

Figure 4.4: Bottom View. The bottom of the charger is shown, featuring ventilation holes for heat dissipation and regulatory compliance markings.

4.1. Controls and Display

  • LCD Display: Shows real-time information such as voltage (V), current (A), capacity (mAh), temperature (°C), and selected mode (Charge, Discharge, Refresh, Test).
  • MODE Button: Used to cycle through the operating modes (Charge, Discharge, Refresh, Test).
  • SLOT Button: Used to select the battery slot (1 or 2) to view or change its settings.

5. Setup

  1. Connect Power: Connect the provided USB Type-C cable to the charger's input port and then to a suitable USB power adapter (DC 5V/2A recommended). The LCD display will illuminate.
  2. Insert Batteries: Carefully insert one or two compatible rechargeable batteries into the charging slots. Ensure the positive (+) and negative (-) terminals of the battery match the markings on the charger. The charger will automatically detect the battery type and display its current voltage.

6. Operating Instructions

The DLYFULL UT2 offers several operating modes for comprehensive battery management.

6.1. Mode Selection

After inserting a battery, the charger will enter a default mode (usually Charge). To change the mode:

  1. Press the SLOT button to select the desired battery slot (if two batteries are inserted).
  2. Press the MODE button repeatedly to cycle through the available modes: CHARGE, DISCHARGE, REFRESH, and TEST.
  3. Once the desired mode is displayed, stop pressing the MODE button. The charger will automatically begin the selected operation after a few seconds.

6.2. Operating Modes Explained

  • CHARGE Mode:

    This is the standard mode for charging batteries. The charger will automatically detect the battery type (Li-ion, Ni-MH, LiFePO4) and apply the appropriate charging algorithm. The display will show charging progress, current voltage, and accumulated capacity.

  • DISCHARGE Mode:

    In this mode, the charger will discharge the battery to a safe voltage level before automatically switching to CHARGE mode. This can help reduce the memory effect in Ni-MH batteries and prepare batteries for storage. The display will show the discharged capacity.

  • REFRESH Mode:

    The Refresh mode is designed to restore the full capacity of older or underperforming Ni-MH batteries. It involves multiple charge-discharge cycles to optimize battery performance. This process can take several hours depending on the battery's condition. The display will show the current cycle and accumulated capacity.

    DLYFULL UT2 charger in use, possibly in refresh mode with batteries

    Figure 6.1: Refresh Mode Example. This image shows the DLYFULL UT2 charger with batteries inserted, potentially illustrating the refresh mode in progress. The display would indicate the current operation.

  • TEST Mode:

    The Test mode measures the actual capacity of a battery. It typically involves fully charging the battery, then fully discharging it while measuring the discharged capacity, and finally recharging it. This provides an accurate assessment of the battery's health and true capacity.

7. Maintenance

  • Cleaning: Use a soft, dry cloth to clean the charger's exterior. Do not use abrasive cleaners or solvents.
  • Storage: When not in use, store the charger in a cool, dry place away from direct sunlight.
  • Battery Contacts: Periodically check the battery contacts for any dirt or corrosion. Clean gently if necessary to ensure good electrical connection.

8. Troubleshooting

ProblemPossible CauseSolution
Charger not powering onNo power connection or faulty cable/adapter.Ensure the USB Type-C cable is securely connected to both the charger and a working USB power adapter. Try a different cable or adapter.
"Low Input" message on displayInsufficient power supply from the USB adapter.Use a USB power adapter that provides at least DC 5V/2A.
Battery not chargingIncorrect battery insertion, incompatible battery, or faulty battery.Check battery polarity. Ensure the battery type is supported. Try a different battery. Clean battery contacts.
Charger or battery gets hotNormal during charging/discharging, but excessive heat indicates an issue.Ensure adequate ventilation. If overheating persists, remove the battery and discontinue use. Contact support.

9. Specifications

The following table details the technical specifications of the DLYFULL UT2 charger.

Table of DLYFULL UT2 charger specifications

Figure 9.1: Technical Specifications. This image displays a table outlining the input, output, discharge current, maximum protection voltages for Li-ion and Ni-MH batteries, and a comprehensive list of compatible battery types and sizes.

FeatureSpecification
InputDC 5V / 2A (USB Type-C)
USB 5V Output2A Max
Discharge Current350mAh
Li-ion Max Protection Voltage4.20V ± 0.05V
Ni-MH Max Protection Voltage1.53V ± 0.05V
Compatible Batteries (Li-ion 3.6V/3.7V)10340, 14500, 16340 (RCR123A), 17500, 17650, 17670, 18490, 18500, 18650
Compatible Batteries (LiFePO4 3.2V)20700, 21700, 22650, 26500, 26650
Compatible Batteries (Ni-MH 1.2V)AA, AAA, C, SC

10. Warranty Information

DLYFULL products are manufactured to high-quality standards. For specific warranty details, please refer to the warranty card included with your purchase or visit the official DLYFULL website. This warranty typically covers manufacturing defects under normal use conditions.

11. Customer Support

If you encounter any issues or have questions regarding your DLYFULL UT2 charger, please contact our customer support team. You can usually find contact information on the DLYFULL official website or through your retailer. Please have your product model (UT2) and purchase details ready when contacting support.

Related Documents - UT2

Preview Dlyfull M4S Battery Charger User Manual
User manual for the Dlyfull M4S battery charger, detailing its features, specifications, operating instructions, and protection functions for various rechargeable battery types.
Preview Unify Drive UT2 User Manual: Personal Cloud Storage and Media Hub
Comprehensive user manual for the Unify Drive UT2, detailing its features as personal cloud storage, family photo album, work assistant, entertainment center, and data guardian. Includes installation, setup, connectivity, and operational guides.
Preview Newport ST-UT/ST-UT2 Optical Table IQ Damping Upgrade Instructions
Comprehensive guide for installing the Newport IQ damping upgrade kit on ST-UT and ST-UT2 optical tables. Includes tools required, step-by-step procedures, and controller setup.
Preview Acer LCD Monitor UT2 Series-UT222Q User Guide
User guide for the Acer LCD Monitor UT2 Series-UT222Q, covering important safety instructions, package contents, connection steps, external controls, FreeSync technology, and regulatory information.
Preview Hive Active Heating Thermostat Installation Guide
A comprehensive guide for installing the Hive Active Heating thermostat, receiver, and hub. Learn step-by-step instructions for setup, wiring, and configuration from British Gas.