KPS KPS-DT100

KPS-DT100 Non-Contact AC Voltage Detector User Manual

Model: KPS-DT100

1. Introduction

The KPS-DT100 is a reliable non-contact AC voltage detector designed for quick and safe identification of live AC voltage. This device is essential for electricians, maintenance personnel, and DIY enthusiasts to ensure electrical safety before working on circuits. It provides clear acoustic and LED indications when AC voltage is detected, covering a wide range from 90V to 1000V AC. The KPS-DT100 is built to meet safety standards, including CAT II 1000V and CAT III 600V, making it suitable for various residential, commercial, and industrial applications.

2. Safety Information

Please read and understand all safety information and operating instructions before using this product. Failure to follow these instructions may result in electric shock, fire, or serious injury.

3. Product Overview

The KPS-DT100 is a pen-style non-contact voltage detector. It features a sensitive tip for voltage detection, an LED indicator, and an audible alarm for clear feedback.

KPS-DT100 product packaging showing features and specifications

Figure 3.1: KPS-DT100 Product Packaging. This image displays the retail packaging of the KPS-DT100, highlighting its key features such as non-contact voltage detection, 90-1000V AC range, acoustic and LED indication, and CAT II 1000V / CAT III 600V safety ratings.

Key Components:

4. Setup

Battery Installation:

The KPS-DT100 requires two AAA batteries (included) for operation. Ensure correct polarity during installation.

  1. Twist the cap at the bottom of the detector counter-clockwise to open the battery compartment.
  2. Insert two AAA batteries, observing the polarity markings (+/-) inside the compartment.
  3. Replace the cap by twisting it clockwise until securely fastened.
  4. Press the power button to turn on the device and confirm it powers up.

5. Operating Instructions

Follow these steps for safe and effective voltage detection:

  1. Power On: Press the power button to turn on the detector. The LED indicator should briefly flash, and a short beep may sound, indicating the device is ready.
  2. Self-Test: Before each use, test the detector on a known live AC voltage source (e.g., a working wall outlet) to ensure it is functioning correctly. The LED should illuminate, and the audible alarm should sound.
  3. Voltage Detection: Place the detection tip of the KPS-DT100 near the conductor, outlet, or circuit you wish to test.
  4. Indication: If AC voltage is present, the LED indicator will light up, and the audible alarm will sound. The intensity of the alarm and LED may vary with voltage strength and proximity.
  5. Power Off: Press the power button again to turn off the detector when finished. The device may also have an auto-off feature to conserve battery life.
KPS-DT100 detecting voltage in a power strip

Figure 5.1: Using the KPS-DT100 to detect voltage in a power strip. The detector's tip is placed near an outlet, and the LED indicator is visible, signifying the presence of AC voltage.

KPS-DT100 detecting voltage in a wall socket

Figure 5.2: A user testing a wall socket with the KPS-DT100. The detector is held firmly, and its tip is inserted into the socket to check for live current.

6. Maintenance

Cleaning:

Wipe the detector with a dry, clean cloth. Do not use abrasive cleaners or solvents. Ensure the device is dry before storage or use.

Battery Replacement:

When the low battery indicator appears, or if the detector does not power on, replace the batteries as described in the "Battery Installation" section (Section 4). Always use fresh AAA batteries.

Storage:

Store the detector in a cool, dry place, away from direct sunlight and extreme temperatures. If storing for extended periods, remove the batteries to prevent leakage.

7. Troubleshooting

ProblemPossible CauseSolution
Detector does not turn on.Dead or incorrectly installed batteries.Replace batteries, ensuring correct polarity.
No indication on a known live source.Low batteries; Detector malfunction.Replace batteries. If problem persists, discontinue use and contact support.
False positives or inconsistent readings.Electromagnetic interference; Detector too close to other conductors; Environmental factors.Move away from strong electromagnetic fields. Ensure proper isolation of the test area. Re-test on a known live source.
Weak or no audible alarm.Low batteries.Replace batteries.

8. Specifications

Model:KPS-DT100
Voltage Range:90V - 1000V AC
Frequency:50/60 Hz
Safety Rating:CAT II 1000V, CAT III 600V
Power Source:2 x AAA batteries
Dimensions:16.85 x 5 x 4.2 cm (approx.)
Weight:50 grams (without batteries)
Standards:IEC 61010-1
Indication:Acoustic and LED

9. Warranty and Support

KPS is committed to providing high-quality products and customer satisfaction.

KPS brand image showing 5 years warranty and lifetime technical support

Figure 9.1: KPS Brand Commitment. This image highlights KPS's commitment to quality, offering a 5-year warranty and lifetime technical support for their products.

You can find more information and products from KPS at their official store: KPS Brand Store

Related Documents - KPS-DT100

Preview KPS FASTCHECK3010 Multifunction Electrical Safety Tester User Manual
User manual for the KPS FASTCHECK3010, a multifunction electrical safety tester. This guide covers its features, operation, and safety precautions for testing electrical systems according to IEC standards.
Preview KPS DCM4000T True-RMS Clamp Meter User Manual
User manual for the KPS DCM4000T True-RMS Clamp Meter. This professional tool accurately measures AC/DC voltage, current, resistance, frequency, continuity, diode, and NCV. Includes operating guidance and safety precautions.
Preview KPS Catalogue Sommaire: Contrôle Énergétique et Solutions Industrielles
Découvrez le catalogue complet de KPS, présentant des solutions innovantes en contrôle énergétique, instrumentation de mesure, matériel d'installation, dispositifs de protection, connexions industrielles, coffrets et signalisation. Améliorez l'efficacité énergétique de vos installations avec des produits de haute qualité fabriqués en Europe.
Preview KPS MT900 Digital Multimeter User Manual
User manual for the KPS MT900 Digital Multimeter, detailing safety instructions, meter appearance, key operations, measurement procedures for AC/DC voltage, resistance, continuity, frequency, duty ratio, and non-contact voltage (NCV), along with general specifications and maintenance.
Preview Manual de Usuario Multicheck6010: Comprobador Multifunción
Guía completa para el uso seguro y eficiente del comprobador multifunción KPS Multicheck6010, cubriendo operación, mediciones, mantenimiento y especificaciones técnicas.
Preview KPS PA700 AC Digital Clamp Meter User Manual
User manual for the KPS PA700 AC Digital Clamp Meter, detailing its features, specifications, safe operation, and measurement guidance for electrical testing.