Jectse Jectsep4nou28s5f

Jectse 2-in-1 Chlorine PH Meter User Manual

Model: Jectsep4nou28s5f

1. Product Overview

The Jectse 2-in-1 Chlorine PH Meter is an essential tool designed for quick and accurate measurement of pH and chlorine (Cl2) levels in swimming pools and spas. This portable device ensures your water remains within safe and ideal ranges for optimal enjoyment and health.

Key Features:

  • Essential Tool: Provides quick and accurate pH and chlorine (Cl2) level measurements.
  • Easy to Use: Features a large screen display for clear and accurate readings, simplifying operation.
  • Durable Construction: Made of high-quality plastic materials, ensuring wear resistance, waterproofing, and long service life.
  • Portable Design: Compact and lightweight for convenient handling and storage.

2. Safety Information

  • Keep the device away from direct sunlight and extreme temperatures.
  • Do not immerse the main body of the meter in water. Only the probe is designed for water contact.
  • Store the device in a dry, cool place when not in use.
  • Keep out of reach of children.
  • Ensure proper battery disposal according to local regulations.

3. Package Contents

Verify that all items are present in the package:

  • 1 x CL2 Chlorine & PH Analysis Meter (Main Body)
  • 1 x Probe with Cable

4. Product Components

Jectse 2-in-1 Chlorine PH Meter with its probe and coiled cable

Figure 4.1: Main unit and probe assembly. The main unit features a large display for readings, and the probe connects via a coiled cable.

Close-up of the meter showing probe slot, telescopic extension cord, and battery compartment

Figure 4.2: Detailed view of the meter's features, including the convenient probe slot for storage, the flexible telescopic extension cord, and the battery compartment for power.

  • Main Body: Houses the display, control buttons, and battery compartment. Dimensions: 190 x 120mm / 7.5 x 4.7in.
  • Probe: The sensing element that is immersed in water. Probe Length: 48mm / 1.9in (excluding black belt). Handle probe length: 150mm / 5.9in.
  • Cable: Connects the probe to the main body. Cable Length: 130mm / 5.1in.

5. Setup

5.1 Battery Installation

  1. Locate the battery compartment on the back of the main unit.
  2. Open the battery cover.
  3. Insert one (1) AA 1.5V alkaline battery, ensuring correct polarity (+/-). (Battery not included)
  4. Close the battery cover securely.

5.2 Initial Preparation

  1. Connect the probe cable to the designated port on the main unit.
  2. Ensure the probe is clean and dry before first use.

6. Operating Instructions

6.1 Measuring pH and Chlorine Levels

Person holding the Jectse meter with the probe immersed in pool water

Figure 6.1: Proper technique for immersing the probe in pool water for accurate readings.

Close-up of the meter's chlorine level display with recommended ranges

Figure 6.2: The chlorine level scale on the meter, indicating ideal and caution ranges. The recommended chlorine content for swimming pools and hot springs is 1.2~1.7ppm.

Close-up of the meter's pH level display with recommended ranges

Figure 6.3: The pH level scale on the meter, showing acid, ideal, and alkaline ranges. The recommended pH for swimming pools and spas is 7.2-7.8.

  1. Before testing, ensure the water sample is still and free of debris.
  2. Press the 'PH/CL2' button to turn on the meter.
  3. Immerse the probe into the water sample, ensuring both metal electrodes are fully submerged.
  4. Wait for the reading to stabilize on the large display.
  5. Read the pH and chlorine (CL2) levels directly from the meter's scale.
  6. Compare the readings with the ideal ranges indicated on the meter's display (e.g., for chlorine: 1.2-1.7ppm; for pH: 7.2-7.8).
  7. After use, remove the probe from the water and wipe it clean and dry.
  8. Press the 'PH/CL2' button again to turn off the meter.

6.2 Calibration

Accurate calibration is crucial for reliable readings. Please follow these steps carefully:

  1. You need to prepare a 1.5 PPM (parts per million) chlorine solution in the pool water for initial calibration. This serves as your reference point.
  2. If you are unsure if the chlorine content is exactly 1.5 PPM, or if you cannot easily create a precise calibration point, it is recommended to use a traditional test strip or a professionally verified water sample to confirm the 1.5 PPM chlorine level.
  3. Once the pool water has been calibrated with the 1.5 PPM chlorine solution, there is generally no need to recalibrate unless you change to measure a different pool's water or if you suspect the meter's accuracy has drifted.

7. Maintenance

7.1 Cleaning

  • After each use, gently wipe the probe electrodes with a soft, clean cloth to remove any water residue or contaminants.
  • Do not use abrasive cleaners or solvents on the meter or probe.
  • Keep the main body dry. If it gets wet, wipe it immediately with a dry cloth.

7.2 Storage

  • Store the meter and probe in a cool, dry place, away from direct sunlight and extreme temperatures.
  • If storing for an extended period, remove the battery to prevent leakage and damage to the device.
  • Utilize the probe slot on the main unit for secure storage of the probe when not in use.

8. Troubleshooting

ProblemPossible CauseSolution
Meter does not turn on.Dead or incorrectly installed battery.Replace the AA 1.5V battery, ensuring correct polarity.
Inaccurate or inconsistent readings.
  • Meter not calibrated.
  • Probe is dirty or damaged.
  • Water sample not stable.
  • Perform calibration as per Section 6.2.
  • Clean the probe thoroughly. If damaged, consider replacement.
  • Ensure the water sample is still and free of bubbles.
Display is dim or flickering.Low battery power.Replace the AA 1.5V battery.

9. Specifications

SpecificationValue
Main Body Size190 x 120mm / 7.5 x 4.7in
Handle Probe Length150mm / 5.9in
Probe Length (excluding black belt)48mm / 1.9in
Cable Length130mm / 5.1in
Power Supply1 x AA 1.5V alkaline battery (NOT included)
MaterialPlastic
Item Weight10.6 ounces
Product Dimensions7.48 x 4.72 x 1.97 inches

10. Warranty and Support

Jectse is committed to providing quality products and customer satisfaction. While specific warranty details are not provided in this manual, if you encounter any issues or have questions regarding your Jectse 2-in-1 Chlorine PH Meter, please contact Jectse customer support through the retailer's platform or the official Jectse website. Our team will endeavor to provide a complete solution within 24 hours.

For more information, visit the Jectse Store on Amazon.

Documents - Jectse – Jectsep4nou28s5f

no relevant documents