Tosuny ES-626

Rate this product if you’ve used it
Download PDF
Contents

Tosuny ES-626 12V 110dB Alarm Siren Instruction Manual

Model: ES-626 | Brand: Tosuny

1. Introduction

Thank you for choosing the Tosuny ES-626 12V 110dB Alarm Siren. This high-volume, dual-tone siren is designed to integrate with various alarm systems, providing an effective audible deterrent for security applications. Its durable, fire-retardant ABS casing ensures long-lasting performance in outdoor environments. This manual provides essential information for proper installation, operation, and maintenance of your alarm siren.

2. Safety Information

  • Power Source: Ensure the siren is connected to a stable 12V DC power source. Incorrect voltage can damage the device.
  • Wiring: All wiring should be performed by a qualified individual to prevent electrical hazards and ensure correct functionality.
  • Mounting: Mount the siren securely to prevent it from falling. Ensure the mounting surface can support the device's weight.
  • Volume: The siren produces a loud 110dB sound. Avoid prolonged exposure to prevent hearing damage.
  • Environment: While designed for outdoor use, avoid mounting in locations directly exposed to extreme weather conditions or excessive moisture.

3. Product Overview

The Tosuny ES-626 alarm siren is a robust and reliable component for any security system. It features a high-decibel output and a durable construction.

Key Features:

  • 110dB Alarm Output: Produces a powerful, dual-tone sound to alert to security breaches.
  • ABS Fire-Retardant Shell: Constructed from flame-retardant ABS material for enhanced durability and safety.
  • Compact and Lightweight: Designed for easy handling and installation.
  • Flexible Installation: Includes a rotatable metal base bracket for adjustable angle and versatile mounting options.
Tosuny ES-626 Alarm Siren

Figure 3.1: Front view of the Tosuny ES-626 Alarm Siren, showcasing its compact design and durable casing.

Tosuny ES-626 Alarm Siren with ABS fire-retardant shell

Figure 3.2: The alarm siren, highlighting its ABS fire-retardant shell, suitable for various environments.

4. Installation & Setup

Proper installation is crucial for the optimal performance of your alarm siren. Follow these steps carefully.

4.1 Mounting the Siren

  1. Choose a Location: Select a suitable location, typically on a wall, near a doorway, balcony, or construction site. For optimal sound dispersion and security, an installation height of 2.5 meters (approximately 8 feet) or more is recommended.
  2. Secure Mounting: Use appropriate screws and anchors (not included) to securely fasten the siren's rotatable metal base bracket to the chosen surface.
  3. Adjust Angle: Adjust the siren's angle using the rotatable bracket to direct the sound effectively. The loudspeaker mouth should face the desired direction for maximum sound spread.
Tosuny ES-626 Alarm Siren mounted outdoors

Figure 4.1: Example of the alarm siren mounted outdoors, demonstrating flexible installation options.

Adjustable angle feature of Tosuny ES-626 Alarm Siren

Figure 4.2: Close-up of the adjustable angle feature, showing the rotatable metal base bracket.

4.2 Wiring Instructions

The siren requires a 12V DC power connection from your alarm panel or power source.

  • Identify the red and black wires extending from the siren.
  • Connect the Red wire to the Positive (+) terminal of your 12V DC power source or alarm panel.
  • Connect the Black wire to the Negative (-) terminal of your 12V DC power source or alarm panel.
  • Ensure all connections are secure and insulated to prevent short circuits.
Wiring diagram for Tosuny ES-626 Alarm Siren

Figure 4.3: Basic wiring diagram connecting the siren to a 12V DC power or alarm panel.

Close-up of Tosuny ES-626 Alarm Siren wiring

Figure 4.4: Detailed view of the siren's wiring, showing red for positive and black for negative connections.

5. Operating Instructions

The Tosuny ES-626 siren operates as an output device for a compatible 12V alarm system. It does not function independently as an alarm system.

  • Activation: When the connected alarm system detects an intrusion or triggers an alarm event, it will send a 12V DC signal to the siren.
  • Alarm Sound: Upon receiving the signal, the siren will emit a loud, dual-tone alarm at 110dB.
  • Alarm Duration: The duration of the siren's sound is controlled by the connected alarm system. Refer to your alarm system's manual for settings related to alarm duration and modes.
  • Alarm Modes: The siren is capable of issuing a 'three alarm' sound pattern, designed to help pinpoint the location of an incident when integrated with a compatible alarm host.
Tosuny ES-626 Alarm Siren activating during an intrusion

Figure 5.1: The alarm siren activating when an illegal entry is detected, alerting to the incident.

Tosuny ES-626 Alarm Siren with 110dB output indication

Figure 5.2: Visual representation of the siren's 110dB treble speaker output.

6. Maintenance

The Tosuny ES-626 alarm siren requires minimal maintenance to ensure its longevity and reliable operation.

  • Cleaning: Periodically wipe the exterior of the siren with a soft, damp cloth to remove dust and dirt. Do not use harsh chemicals or abrasive cleaners.
  • Inspection: Regularly check the wiring connections for any signs of wear, corrosion, or damage. Ensure the mounting bracket remains secure.
  • Testing: Test the siren periodically (e.g., monthly) in conjunction with your alarm system to ensure it is functioning correctly.
  • Environmental Protection: While durable, avoid direct high-pressure water jets or prolonged submersion.

7. Troubleshooting

If you encounter issues with your Tosuny ES-626 alarm siren, refer to the following common problems and solutions.

ProblemPossible CauseSolution
Siren does not sound when alarm is triggered.No power to the siren.
Incorrect wiring.
Faulty alarm panel output.
Check 12V DC power supply.
Verify red wire to positive (+), black wire to negative (-).
Test alarm panel output with a multimeter or another 12V device.
Siren sounds continuously or unexpectedly.Alarm panel malfunction.
Short circuit in wiring.
Consult your alarm system's manual or contact its manufacturer.
Inspect wiring for damage or exposed conductors.
Sound is weak or distorted.Low voltage supply.
Obstruction in front of siren.
Internal damage.
Ensure stable 12V DC power supply.
Clear any objects blocking the siren's output.
If problem persists, contact customer support.

8. Specifications

FeatureSpecification
ModelES-626
Manufacturer Part NumberTosuny8zigwg7h5r
BrandTosuny
Voltage12V DC
Audible Noise110 dB
Wattage15 Watts
MaterialABS Fire-Retardant Shell
ColorBlack
Mounting TypeWall Mount
Compatible with12V Alarm Systems, Power Sources
UPC787015864338
Dimensions of Tosuny ES-626 Alarm Siren

Figure 8.1: Dimensions of the Tosuny ES-626 Alarm Siren (approx. 10.2cm height, 10.6cm depth).

9. Warranty and Support

Tosuny is committed to providing high-quality products and customer satisfaction.

  • Customer Service: If you encounter any problems during the use of this product, please contact Tosuny customer service. We are dedicated to offering the best possible resolution.
  • Warranty Information: For specific warranty terms and conditions, please refer to the product packaging or contact Tosuny customer support directly.

© 2023 Tosuny. All rights reserved.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.

Was this page helpful?