MIPRO MR-823

Mipro MR-823 Dual Hand Wireless Microphone User Manual

Model: MR-823

Introduction

Thank you for choosing the Mipro MR-823 Dual Hand Wireless Microphone system. This manual provides detailed instructions for the proper setup, operation, and maintenance of your new wireless microphone system. Please read this manual thoroughly before using the product to ensure optimal performance and longevity.

Safety Information

  • Do not expose the unit to rain or moisture to prevent fire or electric shock.
  • Do not place objects filled with liquids, such as vases, on the unit.
  • Ensure proper ventilation; do not block any ventilation openings.
  • Only use attachments/accessories specified by the manufacturer.
  • Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way.

Package Contents

Please check the contents of your package to ensure all items are present:

  • 1 x Mipro MR-823 Wireless Receiver Unit
  • 2 x Handheld Wireless Microphones
  • Power Adapter
  • Audio Cable

Product Overview

The Mipro MR-823 system consists of a receiver unit and two handheld wireless microphones, designed for clear and reliable audio transmission.

Mipro MR-823 Dual Hand Wireless Microphone system with receiver and two handheld microphones.

This image displays the complete Mipro MR-823 Dual Hand Wireless Microphone system. It features a sleek, rectangular receiver unit with a control panel and two antennas, accompanied by two black handheld wireless microphones. The microphones have silver grilles and blue accents near the base of the grille.

Receiver Unit Features:

  • Front panel display for channel and status indication.
  • Volume controls for each microphone channel.
  • Antenna inputs for optimal signal reception.
  • Audio output jacks (XLR and 1/4" unbalanced) on the rear panel.

Handheld Microphone Features:

  • Integrated transmitter.
  • Power switch.
  • Battery compartment.

Setup

  1. Unpack Components: Carefully remove all items from the packaging.
  2. Position Receiver: Place the receiver unit on a stable, flat surface, away from potential sources of interference (e.g., computers, Wi-Fi routers). Ensure adequate ventilation around the unit.
  3. Connect Antennas: Screw the two antennas securely into their respective connectors on the rear of the receiver. Position them vertically for best reception.
  4. Connect Audio Output: Connect the receiver's audio output (XLR or 1/4" unbalanced) to your mixer, amplifier, or sound system using the provided audio cable.
  5. Connect Power: Plug the power adapter into the DC input on the receiver and then into a suitable power outlet. Do not power on the unit yet.
  6. Install Microphone Batteries: Open the battery compartment of each handheld microphone and insert fresh batteries, observing the correct polarity.
  7. Power On: Turn on your audio system first, then power on the Mipro MR-823 receiver. Finally, turn on each handheld microphone.

Operating Instructions

Channel Synchronization:

The MR-823 system typically features automatic frequency synchronization. Once the receiver and microphones are powered on, they should automatically link to an available clear channel. Refer to the receiver's display for channel information.

Adjusting Volume:

Use the individual volume control knobs on the front panel of the receiver to adjust the output level of each microphone. Start with a low volume and gradually increase it to avoid feedback or distortion.

Microphone Usage:

  • Hold the microphone approximately 2-6 inches from your mouth for optimal sound pickup.
  • Avoid covering the microphone grille with your hand, as this can affect sound quality and signal strength.
  • Ensure a clear line of sight between the microphones and the receiver for best wireless performance.

Maintenance

  • Cleaning: Use a soft, dry cloth to clean the exterior of the receiver and microphones. Do not use liquid cleaners or abrasive chemicals.
  • Battery Replacement: Replace microphone batteries when the low battery indicator appears or when audio quality degrades. Always use fresh, high-quality batteries.
  • Storage: When not in use for extended periods, remove batteries from the microphones and store the system in a cool, dry place, away from direct sunlight and extreme temperatures.
  • Antenna Care: Handle antennas carefully to avoid bending or breaking.

Troubleshooting

ProblemPossible CauseSolution
No sound from microphoneMicrophone not powered on; Low or dead batteries; Receiver not powered on; Volume too low; Microphone out of range; Frequency mismatch.Ensure microphone and receiver are on; Replace batteries; Check receiver power; Increase volume; Move closer to receiver; Re-sync frequencies if necessary.
Poor sound quality / StaticInterference; Low batteries; Microphone too far from receiver; Obstructions; Incorrect gain settings.Change operating frequency (if available); Replace batteries; Reduce distance; Remove obstructions; Adjust receiver volume.
Feedback (howling sound)Microphone too close to speakers; Volume too high; Room acoustics.Move microphone away from speakers; Lower volume; Adjust speaker placement or use acoustic treatment.
Short wireless rangeObstructions; Interference; Antenna position.Ensure clear line of sight; Re-position antennas; Avoid placing receiver near metal objects or other wireless devices.

Specifications

FeatureSpecification
BrandMIPRO
ModelMR-823
Impedance250 Ohm
Power SourceBattery Powered
Signal-to-Noise Ratio78 dB
Frequency Range100 Hz - 10 KHz
Frequency Response16 KHz
Package Dimensions34.01 x 24.99 x 21.01 cm
Item Weight122 g
Batteries RequiredNo (for receiver, but yes for microphones)
Special FeatureWireless
ColourBlack
Polar PatternOmnidirectional

Warranty and Support

For warranty information and technical support, please refer to the warranty card included with your product or visit the official MIPRO website. Keep your purchase receipt as proof of purchase for any warranty claims.

If you encounter issues not covered in this manual, please contact MIPRO customer service or your authorized dealer for assistance.

Related Documents - MR-823

Preview MIPRO MR-823 / MH-80 / MT-801 / MT-801a UHF Dual-Channel Diversity Wireless Microphone System User Guide
This user guide provides comprehensive instructions for setting up, operating, and maintaining the MIPRO MR-823, MH-80, and MT-801/MT-801a wireless microphone systems. Learn about parts identification, installation, operating tips, and important safety precautions for optimal performance.
Preview MIPRO MR-823 | MH-80 | MT-801 | MT-801a UHF Wireless Microphone System User Guide
User guide for the MIPRO MR-823 Dual-Channel Diversity Wireless Microphone System, including information on the MH-80 and MT-801/MT-801a transmitters. Covers safety instructions, part names, installation, operating tips, and cautions.
Preview MIPRO MU-13, MU-23, MU-210 Headworn Microphone User Guide
Comprehensive user guide for MIPRO MU-13, MU-23, and MU-210 headworn microphones, covering part names, assembly, wearing instructions, adjustment tips, wiring diagrams, and sound quality optimization.
Preview MIPRO MM-58 Wired Microphone User Guide
User guide for the MIPRO MM-58 Wired Microphone, detailing specifications, frequency response, polar pattern, and important cautions for use and disposal.
Preview MIPRO MU-506H/MU-506HS Headworn Microphone User Guide
User guide for MIPRO MU-506H and MU-506HS unidirectional headworn microphones, covering part names, assembly instructions, optimal sound quality tips, wiring illustrations, and company information.
Preview MIPRO MU-57H & MU-57HS Waterproof Headworn Microphone User Guide
Comprehensive user guide for the MIPRO MU-57H and MU-57HS waterproof headworn microphones. This guide details part identification, optional connector types, assembly instructions, tips for optimal sound quality, wiring diagrams, important notes, and environmental disposal guidelines.