1. Introduction

This manual provides detailed instructions for the installation, operation, and maintenance of the Intermatic Electronic Timer, Model ET2105CR. This electronic timer is designed for precise control of electrical loads, offering 24-hour and 365-day operation modes. It features a single channel with SPST contact form, capable of handling 30 Amps at 120 to 277Vac voltage.

Intermatic Electronic Timer in a gray metal enclosure

Figure 1: Intermatic Electronic Timer, Model ET2105CR, enclosed in a durable gray metal casing.

The timer is housed in a NEMA 3R rated metal enclosure, suitable for outdoor use, and includes a capacitor backup for up to 100 hours of operation during power outages. Please read this manual thoroughly before installation and operation to ensure safe and efficient use of the device.

2. Safety Information

Always observe the following safety precautions to reduce the risk of fire, electric shock, or injury to persons:

  • WARNING: Risk of Electric Shock. Disconnect power at the circuit breaker or fuse before installing or servicing.
  • Installation and wiring must be performed by a qualified electrician in accordance with all local and national electrical codes.
  • Do not exceed the maximum electrical ratings of the device (30 Amps, 120-277Vac).
  • Ensure proper grounding to prevent electric shock.
  • Do not use this device for applications where failure could result in dangerous conditions (e.g., medical life support equipment).
  • Keep the enclosure door closed and secured to maintain NEMA 3R rating and protect internal components.

3. Setup and Installation

3.1 Mounting the Timer

The ET2105CR timer is designed for surface mounting. Choose a suitable location that is accessible for wiring and programming, and protected from direct physical damage. Ensure the mounting surface is stable and can support the weight of the timer.

  1. Open the timer enclosure door.
  2. Locate the mounting holes on the back of the enclosure.
  3. Using appropriate screws and anchors (not supplied), securely fasten the timer to the desired surface.
  4. Ensure the timer is level and firmly attached.

3.2 Wiring Instructions

All wiring must comply with the National Electrical Code (NEC) and local codes. Refer to the wiring diagram inside the timer enclosure for specific connections.

  1. ENSURE POWER IS DISCONNECTED AT THE SOURCE BEFORE WIRING.
  2. Route the incoming power supply wires (LINE) and the load wires (LOAD) into the timer enclosure through appropriate conduit openings.
  3. Connect the LINE wires to the designated LINE terminals on the timer.
  4. Connect the LOAD wires to the designated LOAD terminals on the timer.
  5. Connect the ground wire to the ground terminal within the enclosure.
  6. Double-check all connections for tightness and correct polarity.
  7. Close and secure the enclosure door.

4. Operating Instructions

4.1 Initial Power-Up and Display

Once wired and power is restored, the timer's display (1" height, 3" width) will illuminate. The internal capacitor will begin charging, providing backup power for settings retention during power outages.

4.2 Setting Current Time and Date

Before programming ON/OFF events, set the current time and date accurately.

  1. Press the "MENU" button to access the main menu.
  2. Navigate to "SET TIME/DATE" using the arrow buttons.
  3. Press "ENTER" to confirm.
  4. Adjust the year, month, day, hour, and minute using the arrow buttons and confirm each setting with "ENTER".

4.3 Programming ON/OFF Events

The timer supports up to 96 ON/OFF cycles. Each event can be programmed for specific days of the week or daily operation.

  1. From the main menu, navigate to "PROGRAM EVENTS".
  2. Select "ADD NEW EVENT".
  3. Choose "ON" or "OFF" for the event type.
  4. Set the desired time (hour and minute) for the event.
  5. Select the days of the week for the event to be active (e.g., Mon-Fri, Daily, or specific days).
  6. Confirm the event. Repeat for all desired ON and OFF cycles.

4.4 Manual Override

The timer allows for temporary manual override of programmed events.

  • Press the "MANUAL" button to toggle the output state (ON/OFF) without affecting the programmed schedule.
  • The timer will revert to the programmed schedule at the next scheduled event.

5. Maintenance

The Intermatic Electronic Timer is designed for minimal maintenance. However, periodic checks can ensure optimal performance and longevity.

  • WARNING: Disconnect power before performing any maintenance.
  • Cleaning: Periodically wipe the exterior of the enclosure with a soft, damp cloth. Do not use abrasive cleaners or solvents.
  • Inspection: Annually inspect the wiring connections for tightness and signs of corrosion or damage. Ensure the enclosure door seal is intact to maintain its NEMA 3R rating.
  • Battery Backup: The internal capacitor provides backup for settings. If the timer frequently loses its settings after power outages, the capacitor may need servicing by a qualified technician.

6. Troubleshooting

Refer to the table below for common issues and their solutions.

Problem Possible Cause Solution
Timer display is blank. No power to the timer. Check circuit breaker/fuse. Verify wiring connections.
Timer does not switch load ON/OFF as programmed. Incorrect programming; Manual override active; Wiring issue. Review programmed events. Check if manual override is engaged. Verify load wiring.
Timer loses settings after power outage. Capacitor backup not fully charged or failing. Allow timer to remain powered for 24 hours to fully charge capacitor. If issue persists, contact qualified service personnel.
Enclosure shows signs of water ingress. Damaged enclosure seal or improper installation. Inspect enclosure for cracks or damage. Ensure door is properly latched and seal is intact. Re-seal or replace if necessary.

7. Specifications

Feature Detail
Model Number ET2105CR
Operation Mode 24 Hr. / 365 Days
Number of Channels 1
Contact Form SPST
Voltage 120 to 277Vac
Amperage 30 Amps
Max. ON/OFF Cycles 96
Enclosure Metal, NEMA 3R Rated
Mounting Surface
Min. Time Setting 1 Minute
Max. Time Setting 24 Hours
Backup Device Capacitor
Backup Time 100 Hours
Operating Temperature -40°F to 155°F (-40°C to 68°C)
Display Dimensions 1" Height x 3" Width
Product Dimensions (H x W x D) 10-1/8" x 6-1/2" x 3-5/8" (10.13" x 6.5" x 3.63")
Weight 3.32 Pounds
Standards UL Listed, California Title 20 Listed, LED Listed
UPC 078275147966
Intermatic Electronic Timer with dimensions labeled: 10.12 inches height, 6.5 inches width, 3.62 inches depth.

Figure 2: Dimensions of the Intermatic Electronic Timer, Model ET2105CR.

8. Warranty and Support

8.1 Warranty Information

Intermatic products are manufactured under strict quality standards. For specific warranty terms and conditions applicable to your ET2105CR Electronic Timer, please refer to the warranty card included with your product or visit the official Intermatic website. Warranty coverage typically includes defects in material and workmanship for a specified period from the date of purchase.

8.2 Technical Support

If you encounter any issues not covered in the troubleshooting section or require further assistance, please contact Intermatic Customer Support. Have your model number (ET2105CR) and purchase information ready when contacting support.

For the most current contact information, please visit the official Intermatic website or refer to the packaging of your product.

Note: Protection plans offered by third-party sellers are separate from the manufacturer's warranty.

© 2024 Intermatic. All rights reserved.

This manual is subject to change without notice.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.