1. Product Overview

The Medistrom Pilot-24 Lite is a compact and reliable 95Wh CPAP battery designed to provide portable power for your CPAP machine. It serves as both a standalone power source for travel and camping, and a backup power supply during outages. This bundle includes essential DC output cables for direct connection to ResMed AirMini, AirSense 10, and S9 CPAP machines.

Key features include its TSA-approved and FAA-compliant design, durable aluminum casing for heat dissipation, and LG industrial-grade cells for long-lasting power. It also features a built-in USB port for charging other electronic devices and an integrated LED flashlight.

Medistrom Pilot-24 Lite CPAP Battery

Figure 1: Medistrom Pilot-24 Lite CPAP Battery.

Pilot-24 Lite Features Diagram

Figure 2: Overview of Pilot-24 Lite features including size, weight, and battery capacity.

What's Included with Pilot-24 Lite

Figure 3: Contents included in the Pilot-24 Lite package, including the battery, product manual, and specific cables for AirMini, AirSense 10, and S9.

2. Setup and Initial Charge

Before first use, fully charge your Pilot-24 Lite battery. The battery can be charged using your CPAP machine's original AC power adapter. Connect the appropriate charging adapter cable to the battery's "CHARGE" port, then plug the adapter into a wall outlet.

The battery features a 4-stage charge level indicator. When charging, the lights will blink, indicating the current charge level. All four lights will be solid when fully charged.

Pilot-24 Lite connection with AirMini

Figure 4: Connecting the Pilot-24 Lite to a ResMed AirMini CPAP machine for charging or operation.

Pilot-24 Lite connection with AirSense 10

Figure 5: Connecting the Pilot-24 Lite to a ResMed AirSense 10 CPAP machine.

Pilot-24 Lite connection with S9

Figure 6: Connecting the Pilot-24 Lite to a ResMed S9 CPAP machine.

Compatible 24V CPAP Devices

Figure 7: The Pilot-24 Lite is compatible with various 24V CPAP machines. Cables for devices other than AirSense 10, AirMini, and S9 are sold separately.

Charging Mode for AirSense 10

Figure 8: Illustration of the charging mode for the Pilot-24 Lite using the original AirSense 10 AC Power Cable.

Charging Mode for AirMini

Figure 9: Illustration of the charging mode for the Pilot-24 Lite using the original AirMini AC Power Cable.

Charging Mode for S9

Figure 10: Illustration of the charging mode for the Pilot-24 Lite using the original S9 AC Power Cable.

Charge Time Table for Pilot-24 Lite

Figure 11: Approximate charge times for the Pilot-24 Lite using various adapters.

3. Operating Instructions

The Pilot-24 Lite can be used in two primary modes: Travel Mode and Backup Mode.

Travel Mode

In Travel Mode, the Pilot-24 Lite powers your CPAP machine directly, ideal for off-grid use. Connect the appropriate DC output cable from the battery's "DC OUT" port to your CPAP machine.

Travel Mode for AirSense 10

Figure 12: Illustration of the travel mode for the Pilot-24 Lite with an AirSense 10.

Travel Mode for AirMini

Figure 13: Illustration of the travel mode for the Pilot-24 Lite with an AirMini.

Travel Mode for S9

Figure 14: Illustration of the travel mode for the Pilot-24 Lite with an S9.

Backup Mode

In Backup Mode, the Pilot-24 Lite acts as an uninterruptible power supply (UPS). Connect your CPAP machine's original AC power cable to a wall outlet, and then connect the Pilot-24 Lite to your CPAP machine using the DC output cable. If main power is disrupted, the battery will seamlessly take over, ensuring continuous therapy.

Backup Mode for AirSense 10

Figure 15: Illustration of the backup mode for the Pilot-24 Lite with an AirSense 10.

Backup Mode for AirMini

Figure 16: Illustration of the backup mode for the Pilot-24 Lite with an AirMini.

Backup Mode for S9

Figure 17: Illustration of the backup mode for the Pilot-24 Lite with an S9.

Maximizing Runtime

To achieve the maximum runtime of 8-16 hours, it is crucial to disable the humidifier and heated tubing features on your CPAP machine. Runtime varies based on pressure settings and device model. Using these features will significantly reduce battery life to approximately 2-4 hours.

Pilot-24 Lite Runtime Information

Figure 18: Information on achieving 8-16 hours of runtime by disabling humidifier and heated tubing.

CPAP Settings for Maximizing Battery Life

Figure 19: Example of proper settings on a ResMed AirSense 10 to maximize battery life by turning off Climate Control, Humidity Level, and Tube Temperature.

Additional Features

  • USB Output: The Pilot-24 Lite includes a USB-A output port (5V, 2.5A) for charging smartphones, tablets, and other USB-powered devices.
  • LED Flashlight: Press and hold the power button for a few seconds to activate the built-in LED flashlight. This can be useful in low-light conditions or during power outages.

4. Maintenance

Proper maintenance ensures the longevity and optimal performance of your Pilot-24 Lite battery.

  • Cleaning: Wipe the battery's exterior with a soft, dry cloth. Do not use liquid cleaners or immerse the device in water.
  • Storage: Store the battery in a cool, dry place away from direct sunlight and extreme temperatures. If storing for extended periods, ensure the battery is charged to approximately 50-70% capacity and recharge every 3-6 months to prevent deep discharge.
  • Battery Care: Avoid fully discharging the battery regularly. While designed for many cycles, maintaining a partial charge when not in use can extend its overall lifespan.

5. Troubleshooting

If you encounter issues with your Pilot-24 Lite, refer to the following common troubleshooting tips:

  • Battery Not Charging: Ensure the charging cable is securely connected to both the battery's "CHARGE" port and the power adapter, and that the power adapter is plugged into a working wall outlet. Verify the power adapter is the correct voltage for the battery.
  • CPAP Machine Not Powering On/Intermittent Power: Check that the DC output cable is firmly connected to both the battery's "DC OUT" port and your CPAP machine. Ensure the battery has sufficient charge. If the connection feels loose or heats up, the cable may be faulty and require replacement.
  • Short Runtime: Confirm that the humidifier and heated tubing features on your CPAP machine are disabled, as these significantly increase power consumption. Check your CPAP pressure settings; higher pressures consume more power.
  • Battery Beeping: A beeping sound typically indicates that the battery charge is low. Recharge the battery immediately.
  • Flashlight Not Working: Ensure the battery has charge. Press and hold the flashlight button for the specified duration to activate it.

6. Specifications

FeatureSpecification
Capacity95Wh
Cell TypeIndustrial grade genuine LG rechargeable lithium ion cells
Rated Input24V, 60W (NORMAL), 90W (MAX)
Rated OutputDC 24V, 3.75A
USB Out5V, 2.5A
Life SpanOver 500 full charge/discharge cycles
CaseAluminum
Dimensions17cm x 9cm x 2cm (6.7" x 3.5" x 0.8"), 560g (1.3lbs)
Power Gauge4 stage Charge Level Indicator Lights
Recharge Time2-3 hours via Airsense 10 AC Adapter, 7-9 hours via the ResMed AirMini AC Adapter
Pilot-24 Lite Specifications Table

Figure 20: Detailed specifications for the Medistrom Pilot-24 Lite.

7. Warranty and Support

Medistrom products are manufactured to high-quality standards. For specific warranty information, including terms, conditions, and duration, please refer to the warranty card included with your product packaging or visit the official Medistrom website. For technical support, troubleshooting assistance, or to inquire about replacement parts and accessories, please contact Medistrom customer service through the contact information provided in your product documentation.

Related Documents - Pilot-24 lite 645759689818

Preview Medistrom Pilot Flex Virtual Training Guide
Comprehensive guide to the Medistrom Pilot Flex, a portable backup power supply and travel battery for PAP devices. Learn about its features, specifications, compatibility, setup, and warranty.
Preview Medistrom Pilot Flex Virtual Training Guide: Portable PAP Battery
Learn how to use the Medistrom Pilot Flex, a versatile dual-voltage backup power supply and portable travel battery for PAP devices. This guide covers specifications, control panel functions, compatibility with various PAP machines, accessories, setup instructions, and warranty information.
Preview Medistrom 50W Solar Panel Quick Start Guide - Portable Solar Charging
Quick start guide for the Medistrom 50W Solar Panel, detailing how to unfold, connect, and charge your Medistrom Pilot battery. Includes important notes and cautions for optimal performance and battery care.
Preview Medistrom Pilot Flex: Portable PAP Battery & Backup Power Supply Guide
Explore the Medistrom Pilot Flex, a versatile portable battery and backup power solution for PAP devices. This guide covers features, specifications, control panel, compatibility, accessories, and setup instructions.
Preview Medistrom Pilot-Lite and Pilot-24 Lite Quick Start Guide
A quick start guide for Medistrom's Pilot-Lite and Pilot-24 Lite portable PAP batteries, detailing setup, important safety information, and technical support contacts.
Preview Medistrom Pilot-19 Lite CPAP Battery User Manual
Comprehensive user manual for the Medistrom Pilot-19 Lite portable CPAP battery and backup power supply, covering package contents, device compatibility, setup, safety, specifications, care, and troubleshooting.