Walfront PM2019A, PM2019S

Walfront PEAKMETER PM2019A/PM2019S Flexible Clamp Meter Instruction Manual

1. Introduction

This manual provides essential information for the safe and effective operation of your Walfront PEAKMETER PM2019A/PM2019S Flexible Clamp Meter. Please read this manual thoroughly before use and retain it for future reference. This device is a handheld professional detector designed to measure AC current, AC/DC voltage, resistance, and frequency.

Cover of the Walfront PEAKMETER Flexible Clamp Meter user manual

Figure 1: User Manual Cover for Walfront PEAKMETER Flexible Clamp Meter.

2. Safety Information

To ensure safe operation, always adhere to the following safety precautions:

  • Read and understand all instructions before using the meter.
  • Observe all safety warnings and instructions marked on the meter.
  • This meter is rated for CAT III 600V. Do not exceed the maximum input values specified for each function.
  • Do not use the meter if it appears damaged or if the flexible inductor is compromised.
  • Always disconnect the test leads from the circuit before changing functions.
  • Exercise extreme caution when working with live circuits. High voltage can cause electric shock.
  • Keep fingers behind the finger guards on the test leads during measurements.
  • Replace batteries immediately when the low battery indicator appears to ensure accurate readings.

3. Product Overview

The Walfront PEAKMETER PM2019A/PM2019S Flexible Clamp Meter features a flexible inductor for measuring current in hard-to-reach areas. Key components are illustrated below:

Diagram of Walfront PEAKMETER Flexible Clamp Meter components

Figure 2: Labeled components of the PM2019S Flexible Clamp Meter. Includes Flexible Inductor, Lighting, Open/Close points, LED Screen, Backlight button, Lighting button, Data Hold button, Switch button, and Port.

The meter is designed for ease of use with an LCD display, backlight, and a built-in flashlight for visibility in low-light conditions.

Walfront PEAKMETER Flexible Clamp Meter highlighting key features

Figure 3: Key features of the meter include professional AC current and frequency measurement, 6000 counts display, Data Hold, Lighting, and Backlight.

4. Setup

4.1 Battery Installation

The PM2019A/PM2019S is powered by batteries. To install or replace batteries:

  1. Ensure the meter is powered off.
  2. Locate the battery compartment cover on the back of the meter.
  3. Use a screwdriver to open the battery compartment.
  4. Insert new batteries, observing correct polarity (+ and -). (Typically 2x AAA batteries, refer to the compartment for exact type).
  5. Securely close the battery compartment cover.

5. Operating Instructions

5.1 Powering On/Off

  • To power on the meter, press the Switch Button (red circle button).
  • The meter features an auto power-off function to conserve battery life. It will automatically shut down after a period of inactivity.
  • To manually power off, press and hold the Switch Button.

5.2 Automatic Measurement Mode

The meter can automatically identify measured signals and display results. When powered on, it typically defaults to an auto-ranging mode.

Close-up of the Walfront PEAKMETER Flexible Clamp Meter's LCD screen

Figure 4: The LCD screen displays 'AUTO' indicating automatic measurement mode and 'TRUE RMS' for accurate AC measurements.

5.3 AC Current Measurement

To measure AC current:

  1. Power on the meter.
  2. Press the 'Open' button to open the flexible inductor.
  3. Wrap the flexible inductor around a single conductor of the circuit where current needs to be measured. Ensure the inductor is fully closed around the conductor.
  4. Read the AC current value displayed on the LCD screen.
Walfront PEAKMETER Flexible Clamp Meter measuring current around a cable

Figure 5: The flexible clamp meter in use, measuring current around a cable. The meter automatically identifies and displays the measured signal.

5.4 AC/DC Voltage, Resistance, and Frequency Measurement

For voltage, resistance, and frequency measurements, connect the test leads (not explicitly shown but implied by 'Port' and 'Multimeter' function) to the appropriate ports and the circuit under test. The meter will automatically detect the measurement type and display the result.

5.5 Data Hold Function

  • Press the HOLD Button to freeze the current reading on the display.
  • Press the HOLD Button again to release the data hold and resume live readings.

5.6 Backlight and Flashlight

  • Press the Backlight Button (sun icon) to turn on the display backlight for improved visibility in dim conditions. Press again to turn off.
  • Press the Lighting Button (light bulb icon) to activate the built-in flashlight. Press again to turn off.
Walfront PEAKMETER Flexible Clamp Meter with backlight and flashlight active

Figure 6: The meter's LED display with backlight and flashlight active, demonstrating ease of operation and readability in various lighting conditions.

6. Maintenance

6.1 Cleaning

Wipe the meter with a dry, soft cloth. Do not use abrasives or solvents. Ensure the meter is powered off and disconnected from any circuits before cleaning.

6.2 Storage

When not in use for extended periods, remove the batteries to prevent leakage. Store the meter in a cool, dry place, away from direct sunlight and extreme temperatures.

7. Troubleshooting

If you encounter issues with your meter, refer to the following common problems and solutions:

  • No Display: Check battery installation and ensure batteries are not depleted. Replace if necessary.
  • Inaccurate Readings: Ensure the flexible inductor is properly closed around a single conductor for current measurements. Verify correct function selection for other measurements. Check battery level.
  • Auto Power-Off: This is a normal function to save battery. Press the Switch Button to turn the meter back on.

8. Specifications

Technical specifications for the Walfront PEAKMETER PM2019A/PM2019S Flexible Clamp Meter:

ParameterPM2019APM2019S
AC Current30A/300A/3000A ± (3.0%+5)30A/300A/3000A ± (3.0%+5)
DC Voltage6V/60V/600V6V/60V/600V ± (1.0%+3)
AC Voltage6V/60V/600V6V/60V/600V ± (1.2%+3)
Resistance6kΩ/60kΩ/600kΩ/6MΩ6kΩ/60kΩ/600kΩ/6MΩ ± (1.0%+3)
Frequency40Hz-1kHz ± (1.0%+2), 20Hz-1kHz40Hz-1kHz ± (1.0%+2), 20Hz-1kHz
Display Count6000 counts
Power SourceBattery Powered
Dimensions (L x W x H)22.2 x 12 x 2.8 cm (8.7 x 4.7 x 1.1 inches)
Item Weight420 g (0.93 lbs)
Safety RatingIEC 61010-1, CAT III 600V
Walfront PEAKMETER Flexible Clamp Meter with dimensions labeled

Figure 7: Dimensions of the PM2019S Flexible Clamp Meter: 11.3cm/4.4" (head width), 7.5cm/3" (inductor connection length), 16.5cm/6.5" (handle length), 2.5cm/1" (handle base width).

9. Warranty and Support

For warranty information or technical support, please refer to the product packaging or contact your retailer. Keep your purchase receipt as proof of purchase.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.